Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 88 for “"Cherenkov Radiation"”
-
Manipulating Cherenkov radiation by artificial structures
Since its first experimental observation by P. A. Cherenkov in 1934, Cherenkov radiation has attracted widespread attention in both the academia and the industry in the past decades. It is well-known that Cherenkov radiation arises when a charged particle moves at a velocity exceeding the velocity …
-
Simulating Cherenkov radiation generated by radiotherapy beams
Cherenkov radiation has had various applications in high-energy physics since its discovery, and this research explores two applications of Cherenkov radiation relating to its presence in media under irradiation by medical radiotherapy beams. In real-time organic scintillating fiber dosimeters, the …
-
Design, Analysis and Optimization of a Cherenkov radiation based sub-mm/THz BWO
The Terahertz (THz) radiation –also known as “T-ray and THz gap”– refers to a certain band of the electromagnetic spectrum whose frequency extends between 0.1THz and 10THz. Compared to the microwave band, the THz radiation has higher frequency. Therefore, it can be used for high capacity wireless …
-
Considerations for Cherenkov Radiation Imaging in External Beam Radiotherapy for Diverse Populations in a High Throughput Cancer Clinic
Cherenkov radiation imaging is a burgeoning field of optical imaging that has become a promising, non-invasive, technique that allows the visualization of radiation delivery during external beam radiotherapy. This form of imaging has opened the door to real-time and retrospective treatment …
-
Covariant Theory of Electromagnetism and Radiation in Vacuum and Media
I study radiation emission by classical relativistic charged particles interacting with strong electromagnetic fields including the case of motion in vacuum (Larmor radiation) as well as in matter (Cherenkov radiation). I employ a consistent covariant formulation throughout the thesis. I provide …
-
A total absorption spectrometer for gamma rays
… rays is given. The spectrometer depends on the Cherenkov radiation emitted in 14 inches of lead glass by the shower electron-positron pairs formed by an incident gamma ray. The Cherenkov radiation is detected only when four photomultiplier s looking at the glass operate in coincidence. The added …
-
Monte-Carlo study of Cherenkov light polarisation in IACT: The case of VERITAS
The role of polarisation of Cherenkov radiation is a topic seldom discussed in the context of imaging Cherenkov telescope (IACT) systems. A Monte-Carlo simulation code based on CORSIKA was developed to study the effect of Cherenkov radiation polarisation in IACT. The IACT we simulated for this …
-
Nonlinear propagating exciton-polaritons in microcavity wires and waveguides
… in this thesis, is required for the formation of Cherenkov radiation and bright conservative solitons. The study of polariton propagation in both systems is necessary as they could be used for different technological applications, such as amplifiers and optical processing and transmission. …
-
TIME-RESOLVED FRACTOLUMINESCENCE CHARACTERIZATION IN SODA-LIME GLASS VIA NEAR HYPERVELOCITY KINETIC IMPACT FAST FRACTURE
… of non-bridging oxygen hole centers, and even Cherenkov radiation. This thesis investigated whether FL can be observed in SLG via near-hypervelocity kinetic impact utilizing a 40 mm powder gun. Target systems include both planar impact for standard diagnostics and gap-sealed cylindrical …
-
Electron Energy Loss Spectroscopy for Probing Nanophotonic Excitations at High Energy and Momentum
… we propose a tunable and broadband thresholdless Cherenkov radiation source in the EUV using silicon plasmonic metamaterials.In chapter 4 we expand the use of k-EELS to probe more exotic nanophotonic structures in the form of Bi2Te3, a naturally occurring hyperbolic material. Hyperbolic materials, …
-
Simulation and Detection of Cherenkov Light in Water Neutrino Detectors
Cherenkov light plays a crucial role in particle physics and is used in a wide variety of neutrino experiments to observe the secondary charged particles created after neutrino interaction. In this thesis, we consider two ways to improve both the simulation of Cherenkov light and the design of …
-
Development of novel microfluidic systems for radionuclide detection
… provides theoretical background on β emission, Cherenkov radiation, and microfluidic parameters. These parameters have been modelled and experimentally validated on simple and complex microfluidic systems with radiological (Cherenkov radiation) and non radiological (chemiluminescence) testing. …
-
Cherenkov and transition radiation as low-energy background sources in SuperCDMS detectors
… charges in uniform motion, specifically from Cherenkov radiation (CR), transition radiation (TR), and the intermediate hybrid transition-Cherenkov radiation (HR). In the latter case, the standard formulae for HR contain divergences at certain angles in transparent media, which are an artifact …
-
Amorphous Silicon Based Microchannel Plates for Time-of-Flight Positron Emission Tomography
… detector in this project focuses on using Cherenkov radiation rather than scintillation to determine the annihilation site during time-of-flight PET imaging. Since Cherenkov radiation is instantaneous, this approach could significantly improve the timing resolution and, consequently, the …
-
Characterization of photomultiplier DOM for Cherenkov detectors
… tests of charge linearity, uniformity, gain, and Cherenkov radiation. The charge is linear in transmittance with a chi^2/ndf of 2.42. The DOM shows a radial decrease in sensitivity with a slight angular asymmetry. A nominal gain of 10^7 is reached near 1400 HV. These tests are found to largely …
-
A classical view of the quantum vacuum
… charged particle moving through a medium emits Cherenkov radiation when its velocity exceeds the phase velocity of light in that medium. Under the influence of a strong electromagnetic field the nonlinear nature of the vacuum allows for the possibility of high-energy particles to radiate via the …
-
Quantifying Australian atmospheric properties for a gamma-ray observatory to operate at energies greater than 10 TeV.
… ≥ 10 TeV (1 TeV = 10¹² eV) imaging atmospheric Cherenkov technique (IACT) γ-ray experiments will need optimal sites for their construction and operation at energies above 10 TeV. Quantifying the optical properties of Australian atmospheres will be part of a site survey to determine the viability …
-
Direction Reconstruction in the SNO+ Liquid Scintillator Phase with 2.2 g/L PPO
… scintillators implies the loss of early Cherenkov radiation which entails forfeiting directionality in solar neutrino interaction identification. That is, unless timing resolution of these detectors allows for the separation of the early Cherenkov light from the prompt scintillation …
-
Metamaterial structures for Wakefield acceleration and high power microwave generation
… and simulated. The novel phenomenon of reversed Cherenkov radiation has been found to enhance the beam-wave interaction in metamaterials. A metallic wagon wheel metamaterial structure was designed and built for use in an experiment at the Argonne Wakefield Accelerator (AWA) Facility. On the …
Page 1 of 5