Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 46 for “"Cherenkov detectors"”
-
Characterization of photomultiplier DOM for Cherenkov detectors
… tests of charge linearity, uniformity, gain, and Cherenkov radiation. The charge is linear in transmittance with a chi^2/ndf of 2.42. The DOM shows a radial decrease in sensitivity with a slight angular asymmetry. A nominal gain of 10^7 is reached near 1400 HV. These tests are found to largely …
-
Development of nanosecond range light sources for calibration of astroparticle cherenkov detectors
In this thesis the development of light emitting diodes (LED) is reviewed. The emphasis is put on devices emitting at the blue region of the spectrum. The physical characteristics of these devices are considered. The main interest is based around the ability of blue LEDs to generate nanosecond …
-
Cherenkov detectors for transmission studies of monoenergetic high-energy photons in active interrogation applications
… pursuit of shielded special nuclear materials. Cherenkov detectors can be used for a variety of purposes, including imaging of the cargo contingent upon gamma ray energies used in interrogation. If the gamma ray energies are sufficiently well separated, as the case in …
-
A first photogrammetric analysis of the Super-Kamiokande detector : calibrating water Cherenkov detectors with photogrammetry
… experiment is a 50 kiloton water Cherenkov detector located in the Kamioka Observatory in Japan. It is used to study neutrinos from the Sun, supernovae, cosmic rays and a neutrino beam produced at the Japan Proton Accelerator Research Complex 300 km away. The detector is composed …
-
Development of In-situ Gelling for mPMT Assembly for Water Cherenkov Detectors in the HyperK Experiment
This thesis presents advancements in multi-PMT (mPMT) detector assembly, particularly focusing on the in-situ gelling method that encompasses novel assembly procedures, including the incorporation of air channels, pillar cavities, and design elements into the inner support. A unique two-part foam …
-
A search for photons of energy above 6 × 10¹⁸ eV using data from the Water-Cherenkov detectors of the Pierre Auger Observatory
… first time that a parameter based on the surface detectors from the Pierre Auger Observatory is valid for the entire zenith angle range and even for energies below 10¹⁹ eV. 81, 9, 2, 0 and 0 photon-like events were found for the energies above 10¹⁸·⁸, 10¹⁹, 2 × 10¹⁹, 3 × 10¹⁹ and 4 × 10¹⁹ eV …
-
Testing of GdCl3 Doping in Water Cherenkov Antineutrino Detectors
… neutron and neutrino detection using water Cherenkov detectors loaded with gadolinium has been proposed for potential application in both large and small volume detectors. In this thesis, work performed to determine the effect on transparency resulting from use of GdCl3 in stainless steel …
-
Cherenkov Gamma Ray Detectors on High-Energy-Density Systems
… pulse and a noisy radiation environment. Cherenkov detectors to measure energy thresholded, time resolved gamma rays is one such technique that can be applied to these systems to gain insight and understanding to the properties of HED systems. In this dissertation, the fundamentals and …
-
Calibration of the HAWC Gamma-Ray Observatory
The High-Altitude Water Cherenkov (HAWC) Experiment is a gamma-ray observatory that utilizes water silos as Cherenkov detectors to measure the electromagnetic air showers created by gamma rays. The experiment consists of an array of closely packed water Cherenkov detectors (WCDs), each with four …
-
Measuring Light Distribution of LED Sources for Hyper-Kamiokande Detector Calibration
The Hyper-Kamiokande experiment uses water-Cherenkov detectors to study neutrino oscillation and charge conjugation parity (CP) violations with high precision. To reduce systematic errors, multi-photomultiplier tube modules (mPMTs) that comprise the Cherenkov photon detectors will include LED light …
-
Time Calibration of IWCD: A new water Cherenkov near detector for Hyper-Kamkiokande
… calibration of a new Intermediate Distance Water Cherenkov Detector (IWCD) for the long-baseline neutrino oscillation experiment from Tokai to Hyper-Kamiokande. The timing calibration method studied for water Cherenkov detectors uses a flash of light in the detector and can be applied in any water …
-
High Energy Neutrino Analysis at Kamland and Application to Dark Matter Search
… technologies for neutrino detection, namely Cherenkov and scintillator detectors. In the past, scintillator detectors have traditionally been used much like calorimeters to analyze neutrinos at lower energies of ~MeV, whereas neutrino directionality and flavor discrimination at higher energy …
-
Design, calibration, and early results of a surface array for detection of ultrahigh energy cosmic rays
… The surface detector is an array of 1600 water Cherenkov detectors, spaced 1.5 km apart for a total area of 3000 km <sup>2</sup>, planned to operate continuously for 20 years. The detectors therefore must be inexpensive, low power, easy to deploy, and have a high reliability. Each surface …
-
The TeV γ-ray emission of the Galactic Plane. HAWC and H.E.S.S. observations of the Galactic Plane and detailed study of the region surrounding 2HWC J1928+177.
… ground-based facilities: Imaging Atmospheric Cherenkov Telescopes, and Water Cherenkov Detectors. This thesis focuses on H.E.S.S., an array of five Cherenkov telescopes, and HAWC, a wide field of view γ -ray observatory, that are very complementary despite their technical differences. Part of …
-
The CHIPS Prototype Water Cherenkov Detector
The CHIPS (CHerenkov detectors In mine PitS) detector was a large-scale water Cherenkov (WC) long baseline neutrino detector located in northern Minnesota. It was located 7 mrad off-axis, 712 km downstream from the NuMI neutrino source at Fermi National Accelerator Laboratory and with a fiducial …
-
Convolutional Neural Networks for the CHIPS Neutrino Detector R&D Project
The CHerenkov detectors In mine PitS (Chips) neutrino detector R&D project aims to develop novel strategies and technologies for very large yet ‘cheap as chips’ water Cherenkov neutrino detectors. Via deployment in a body of water, use of commercially available components, and instrumentation …
-
Identifying the Origin of Galactic Cosmic Rays with the SuperTIGER Instrument
… a combination of three scintillator and two Cherenkov detectors, and employs a scintillating fiber hodoscope for event trajectory determination. The SuperTIGER data have been analyzed to correct for instrument effects and remove events that underwent nuclear interactions within the …
-
Imaging of special nuclear materials using monochromatic gamma rays from low-energy nuclear reactions
… employing discrete energy photons. A variety of detectors can be used for imaging cargo contingent upon the energies and fluence used in the interrogation. If the gamma ray energies are sufficiently well separated, as the case in 11B(d,n-γ)12C reaction resulting in photons of numerous energies up …
-
Muon data calibration for Auger@Ta
… based on air showers detected using surface detectors from both projects: TA scintillator detectors vs.~Auger Water Cherenkov Detectors (WCD). Auger@TA (Phase 2) consists of a small array of Auger WCD surface detector stations deployed within the existing TA observatory near Delta, Utah. This …
Page 1 of 3