Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"Chewing simulation"”.

  1. Influence of zirconia ceramic abutment preparation on the fracture strength of single implant restorations after chewing simulation.

    … (C) at 135° with 98N in a thermomechanical chewing simulator (Kausimulator, Willytech) up to 1.2x106 loading cycles; followed by quasi-static loading until fracture. All specimens survived dynamic loading except one (in group CPB) that fractured early and was considered as manufacturer’s …

    cau-kiel Repository record for Influence of zirconia ceramic abutment preparation on the fracture strength of single implant restorations after chewing simulation. (opens in a new tab)

  2. In-Vitro Comparative Evaluation of the Physical Properties of Three Dimensional-Printed and Milled High Performance Ceramics

    … pressed zirconia, and 2) thermocycling and chewing simulation does not affect the flexural strength of 3D printed yttria-stabilized zirconia. Material and methods: 30 bars of printed yttria-stabilized zirconia and 10 bars of milled yttria-stabilized, isostatic pressed zirconia were utilized …

    penn Repository record for In-Vitro Comparative Evaluation of the Physical Properties of Three Dimensional-Printed and Milled High Performance Ceramics (opens in a new tab)

  3. Impact of gluma desensitizer on the tensile strength of zirconia crowns bonded to dentin: An in-vitro study

    … and the other half (n=12) was subjected to a chewing machine (1.2 Mio, 49N, 5°C/50°C). The cemented crowns were pulled in a Universal Testing Machine (1 mm/min, Zwick Z010) until failure occured and the tensile strength was calculated. Data were analyzed with one-way and two-way ANOVA followed …

    zurich Repository record for Impact of gluma desensitizer on the tensile strength of zirconia crowns bonded to dentin: An in-vitro study (opens in a new tab)

  4. Retention Force Provided by Custom-Made and Native Locator Abutments - An In Vitro Study

    … Vivadent). The specimens were subjected to chewing simulation corresponding to six months of clinical service. Tensile retentive force was recorded using a universal testing machine before and after chewing simulation. Pre-test and post-test pictures were taken for all specimens using a …

    buffalo Repository record for Retention Force Provided by Custom-Made and Native Locator Abutments - An In Vitro Study (opens in a new tab)

  5. Can fiber-reinforced resin composites alone substitute adhesively luted intraradicular post and core materials under static and dynamic loading?

    … water storage, the other half was subjected to chewing simulation (x1.200.000; 5–55 °C). Data for Finitial (N) and Fmax (N) were analyzed using 2-way ANOVA and Tukey’s tests (alpha = 0.05). Fracture strength values were significantly affected by the post and core type (p < 0.05) and the fatigue …

    zurich Repository record for Can fiber-reinforced resin composites alone substitute adhesively luted intraradicular post and core materials under static and dynamic loading? (opens in a new tab)

  6. Comparative Study of the tooth- colored Ivotion resin with commercially available resin teeth

    … Abrasion of the specimen was measured after the chewing simulation (50N; 10 000, 200 000, 600 000 cycles) with the GOM 2021 software by matching the pre- and post- chewing simulation scans (InEOS X5). Hardness of the materials was measured with the Vickers indenter using the FISCHERSCOPE 340 and …

    wurz-thes Repository record for Comparative Study of the tooth- colored Ivotion resin with commercially available resin teeth (opens in a new tab)

  7. The influence of post material, post diameter and substance loss on the fracture resistance of endodontically treated premolars

    … with glass ionomer cement. After 1,200,000 chewing simulation cycles with a load of 49 N and simultaneous thermocycling (5°C-55°C), specimens were quasi-statically loaded at 30 degrees to the longitudinal axis of the tooth until fracture. Fracture loads were analyzed by using 3-way ANOVA …

    cau-kiel Repository record for The influence of post material, post diameter and substance loss on the fracture resistance of endodontically treated premolars (opens in a new tab)

  8. Resurrecting an Ancient Bite: Virtual Chewing Model Sheds Light on one of the Earliest Primates

    … of primate origin is deciphering early primate chewing anatomy, as it can help paleontologists to infer a range of features including diet, body form and function and evolution. (Perry, 2008). The study of such ancient anatomy is inherently difficult, however, due to their fossil remains often …

    jhu Repository record for Resurrecting an Ancient Bite: Virtual Chewing Model Sheds Light on one of the Earliest Primates (opens in a new tab)

  9. Development and Validation of an In vitro Model to Simulate Oral Challenges on Dental Materials

    … wear under two conditions: CRA-:1 mechanical (chewing simulation up to1.2 million cycles, 50 N) and thermal (up to 50,000 thermocycles, 5-55 ˚C) challenges; CRA-2: mechanical, thermal and acidic challenges (HCl immersion, pH 1.2, up to 15 hours) were applied. Enamel wear was assessed and …

    toronto-retro Repository record for Development and Validation of an In vitro Model to Simulate Oral Challenges on Dental Materials (opens in a new tab)

  10. Failure load of monolithic and veneered Y-TZP and glass ceramic subjected to aging and fatigue

    … 10 specimens were subjected to cyclic loading (chewing simulation) in a water bath for 50,000 cycles at a frequency of 1 Hz at 30% of the mean failure load, and then were loaded under compression to fracture. Another 10 specimens were subjected to a thermo-cycling test, then loaded under …

    bu Repository record for Failure load of monolithic and veneered Y-TZP and glass ceramic subjected to aging and fatigue (opens in a new tab)

  11. A systematic review and meta-analysis on fracture resistance of dental zirconia implants in vitro

    Various protocols are available to preclinically assess the fracture resistance of zirconia oral im plants. The objective of the present review was to determine the impact of different treatments (dynamic load ing, hydrothermal aging) and implant features (e.g., material, design or manufacturing) …

    fu-berlin Repository record for A systematic review and meta-analysis on fracture resistance of dental zirconia implants in vitro (opens in a new tab)

  12. Endodontisch behandelte Frontzähne als Pfeiler für Zirkonoxid-basierte Kronen mit distaler Extension

    … nach thermo-mechanischer Wechsellast (sog. Kausimulation), die 10 Jahre klinische intraorale Funk-tion nachstellen soll, evaluiert. Material und Methode: Menschliche, obere, mittlere Schneidezähne wurden endodontisch behandelt und in folgende 5 Gruppen unterteilt (n=8): (1) Zugangskavität, …

    fu-berlin Repository record for Endodontisch behandelte Frontzähne als Pfeiler für Zirkonoxid-basierte Kronen mit distaler Extension (opens in a new tab)

  13. Rekonstruktion endodontisch behandelter Zähne glasfaserverstärkte Aufbaustifte in vivo und in vitro

    … dass die thermomechanische Wechsellast (Kausimulation) gefolgt von einer linearen Belastung bis zum Versagen für die Untersuchungen zur Aufbaustiftproblematik am geeignetsten ist. Ferner wurde die verbliebene Wurzelwandstärke auf Niveau des Kanaleinganges als eine limitierende Größe in der …

    fu-berlin Repository record for Rekonstruktion endodontisch behandelter Zähne glasfaserverstärkte Aufbaustifte in vivo und in vitro (opens in a new tab)

  14. Adhäsive Rekonstruktion endodontisch behandelter, oberer, mittlerer Schneidezähne mit glasfaserverstärkten Kompositaufbaustiften und Vollkeramikkronen

    … und -materialien sowie der Einfluss der Kausimulation auf die maximale Belastbarkeit ausgewertet. Die Resultate der vorliegenden Untersuchung lassen sich in abschließend genannten Schlussfolgerungen zusammenfassen: Die maximale Belastbarkeit adhäsiv rekonstruierter, endodontisch behandelter, …

    fu-berlin Repository record for Adhäsive Rekonstruktion endodontisch behandelter, oberer, mittlerer Schneidezähne mit glasfaserverstärkten Kompositaufbaustiften und Vollkeramikkronen (opens in a new tab)

  15. CAD/CAM Resin-Based Composites for Use in Long-Term Temporary Fixed Dental Prostheses

    … verwendet. 10/20 Brücken wurden einer Alterungssimulation mittels Thermocycling und mechanischer Belastung durch Kausimulation unterzogen und die anderen 10 Brücken wurden in destilliertem Wasser gelagert. Zwei Brücken von jedem Material wurden vor und nach der Kausimulation einer zusätzlichen …

    qucosa-diss