  1. Modeling of Passive Chilled Beams for use in Efficient Control of Indoor-Air Environments

    … of indoor air environments. Halton passive chilled beams are used to cool rooms and the focus of this work is to model the beams. This work also reviews the mesh making process in Gmsh. ANSYS Fluent was used throughout the entire research and this thesis describes the software and a careful …

    vt Repository record for Modeling of Passive Chilled Beams for use in Efficient Control of Indoor-Air Environments (opens in a new tab)

  2. Evaluating the performance of passive chilled beams with respect to energy efficiency and thermal comfort

    Existing modeling approaches for passive chilled beams determined from tests on individual chilled beams in a laboratory are not adequate for assessing overall energy usage and occupant comfort within building simulation programs. In addition, design guidelines for passive chilled beam systems are …

    purdue-thes Repository record for Evaluating the performance of passive chilled beams with respect to energy efficiency and thermal comfort (opens in a new tab)

  3. Modeling and Control of Passive Chilled Beams with Underfloor Air Distribution of Ventilation in Office Buildings in Humid Climates

    … and comfort conditions associated with passive chilled beams for office buildings in a humid climate and to develop a method for the modeling of passive chilled beams with a ventilation system and underfloor air distribution (UFAD). For the analysis, a 606,900 ft2 commercial office building in …

    tamu Repository record for Modeling and Control of Passive Chilled Beams with Underfloor Air Distribution of Ventilation in Office Buildings in Humid Climates (opens in a new tab)

  4. Space Cooling using Active Chilled Beams and Free Cooling by Outdoor Air: A Performance Assessment Based on Simulations in IDA ICE

    … air in a space cooling system using active chilled beams (ACB). The objective of this thesis is to develop a system model in IDA ICE that extract cooling from ambient air by utilizing the air flow of the existing air handling unit, substituting purchased district cooling with free cooling …

    chalmers Repository record for Space Cooling using Active Chilled Beams and Free Cooling by Outdoor Air: A Performance Assessment Based on Simulations in IDA ICE (opens in a new tab)

  5. INVESTIGATION OF FACTORS AFFECTING OPERATIONAL INDUCTION RATIOS AND ASSESSMENT OF THE THERMAL COMFORT OF ACTIVE CHILLED BEAMS (ACBS) IN A FIELD STUDY

    Active chilled beams (ACBs) are an energy-efficient HVAC system that provides cooling to an indoor space by circulating water through a cooling coil. The primary supply air through nozzles can induce secondary air flow through the coil for heat transfer, resulting in more efficient cooling of the …

    nus Repository record for INVESTIGATION OF FACTORS AFFECTING OPERATIONAL INDUCTION RATIOS AND ASSESSMENT OF THE THERMAL COMFORT OF ACTIVE CHILLED BEAMS (ACBS) IN A FIELD STUDY (opens in a new tab)

  6. Design of Active Chilled Beam systems: Detailed economic analyses for different design temperatures and airflows

    … demands. An alternative cooling system is active chilled beams (ACB). ACB is a ceiling-mounted convection unit that decouples ventilation from thermal conditioning facilitating a potential for energy and cost savings. This thesis aims to compare the energy and life-cycle costs (LCC) between the …

    chalmers Repository record for Design of Active Chilled Beam systems: Detailed economic analyses for different design temperatures and airflows (opens in a new tab)

  7. The Effect of Thermal Load Configurations on Passive Chilled Beam Performance

    … configurations on the performance of passive chilled beams. Experiments in a thermally controlled test room were conducted using thermal manikins as heat sources cooled with a 0.6 m by 2.4 m beam. The thermal manikins were arranged in a symmetric and an asymmetric configuration and tested over …

    tamu Repository record for The Effect of Thermal Load Configurations on Passive Chilled Beam Performance (opens in a new tab)

  8. Environmentálně vyspělá administrativní budova ve Vyškově

    Cílem diplomové práce je návrh environmentálně vyspělé administrativní budovy s důrazem na energetickou hospodárnost, technickou kvalitu a komfort vnitřního prostředí. Práce je zpracována formou projektové dokumentace novostavby administrativního objektu situovaného ve městě Vyškov a zahrnuje …

    brno-tech Repository record for Environmentálně vyspělá administrativní budova ve Vyškově (opens in a new tab)