Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 63 for “"Chlorine concentration"”.
-
Effectiveness of In-Line Chlorination of Gravity Flow Water Supply in Two Rural Communities in Panama
… in a rural water supply system. Free and total chlorine were measured entering the storage tank, leaving the storage tank, and at three households along the transmission line of the water system in the two rural indigenous communities of Calabazal and Quebrada Mina in western Panama during …
-
The effects of hypochlorite on bacterial capsular material
The uptake of chlorine by mixed bacterial cultures of varying polysaccharide content was studied in a homogeneous reaction system. The destructive effects of hypochlorite oxidation were noted by measuring decreases in solids concentrations of bacterial cultures and by measuring changes in molecular …
-
Stochastic characterization of flow and transport in networks
… using geostatistical tools. We found that the chlorine concentration at nodes along a straight pipe segment show similar temporal profiles. We also observed that network operating conditions such as the presence of storage tanks and their volumetric capacity influenced the pattern of …
-
Solar cell based on electrodeposited CdS and CdTe films.
… the CdTe layer of a CdS/CdTe solar cell with chlorine brings about significant improvements in the efficiency of these devices. This report presents results on a systematic variation of the chlorine concentration within a CdTe deposition bath. Solar simulated I-V measurements of completed …
-
Electrochemical Oxidation of Chlorination Byproducts in Swimming Pool Applications
… results suggest that the byproducts from urea-chlorine reaction vary with initial chlorine concentrations. Having a higher amount of free chlorine induces transformation of monochloramine, dichloramine, and chlorourea into volatile trichloramine, nitrogen, and nitrate. In this work, free …
-
Microfabricated pH, temperature, and free chlorine sensors for integrated drinking water quality monitoring systems
The monitoring of pH and free chlorine concentration in drinking water is important for water safety and public health. However, existing laboratory-based analytical methods are laborious, inefficient, and costly. This thesis focuses on the development of an easy-to-use, sensitive, and low-cost …
-
Modeling Manganese Sorption and Surface Oxidation During Filtration
… (MnOx(s)) media and is then oxidized by chlorine, forming more manganese oxide. This research builds on a previous model developed by Merkle et al. (1997) by either neglecting the empirically determined available fraction of sorption sites (referred to as the "simple" model), which took …
-
The selective use of chlorine to inhibit algal predators and avoid pond crashes for the algae-biodiesel industry
… Research was conducted in five stages. First, chlorine dissipation tests were carried out using spring water, distilled water, Bolds Basal Medium (BBM), and three different dry weights of algal suspension in order to analyze the dissipation rate of the residual chlorine. The results showed that …
-
ΥΓΕΙΟΝΟΜΙΚΗ ΚΑΙ ΜΙΚΡΟΒΙΟΛΟΓΙΚΗ ΕΡΕΥΝΑ ΤΩΝ ΣΥΣΤΗΜΑΤΩΝ ΥΔΡΕΥΣΗΣ ΣΤΗΝ ΕΛΛΑΔΑ
… WAS OF POOR QUALITY AND THE RESIDUAL CHLORINE CONCENTRATION TEST WAS PERFORMED DAILY IN 25,8% OF WATER UTILITIES. THE SOURCES OF WATER HAD ADEQUATE SANITARY PROTECTION IN 30,8% OF WATER SUPPLIES. FROM THE BACTERIOLOGICAL EXAMINATION, IT WAS CONCLUDED THAT 70% OF THE SAMPLES FROM DUG …
-
Effect of water distribution system on drinking water quality in First Nations communities in Manitoba, Canada
… stored in insulated shelters. Free residual chlorine concentration was significantly lower in water samples from homes with cisterns than piped water. The frequency and severity of Escherichia coli and total coliform contamination were significantly greater in drinking water from belowground …
-
Interactions between semi-volatile toxic metals and sorbents in combustors
… temperature, sorbent/metal molar ratio and chlorine concentration on the capture of toxic metals by sorbents. In general, kaolinite and PWDS reacted rapidly with lead and achieved ∼100% lead sorption in a short time while cadmium was absorbed rapidly by lime only. The lead/lime reaction …
-
Detection, formation and reactivity of Tetravalent Lead Corrosion Product (PbO2) and its role in Water Quality in Drinking Water Distribution System
… to the available Pb(II) solid surface area, free chlorine concentration and OH- concentration, respectively. Investigation on the stability of PbO2 in NH2Cl solutions containing Br- indicated that the reductive dissolution of PbO2 can be accelerated via Bromide-catalyzed NH2Cl decomposition.
-
Mercury emission control for coal fired power plants using coal and biomass
… mercury (HgCl2) is soluble in water. The chlorine concentration present during coal combustion plays a major role in mercury oxidation, which is evident from the fact that plants burning coal having high chlorine content have less elemental mercury emissions. A novel method of co-firing …
-
THE EFFECTS OF REPEATED CHLORINATION ON BIOFILM DEVELOPMENT UNDER DIFFERENT NUTRIENT CONCENTRATIONS USING A MICROLFUIDIC DEVICE
… significantly in the presence of residual chlorine, suggesting that nutrient deprivation and chlorination have been individually ineffective in eradicating biofilms. This study investigated biofilm development under different nutrient conditions coupled with subsequent chlorination. The …
-
Experimental investigation of simultaneous hydrogen production and sodium hypochlorite formation in a carbon-based saline water electrolysis system
… The effects of applied voltage, NaCl concentration, temperature, electrolysis time, and current distribution method are examined. Hydrogen production and active chlorine formation increase with applied voltage and NaCl concentration. The maximum production occurs at 0.7 M NaCl, 30°C, …
-
Comparison Of The Effectiveness Of Alternative Ferrate (vi) Synthesis Formulas As Disinfectants For Wastewater And River Water
… stoichiometric requirement of hypochlorite (Low Chlorine Formula) while the other ferrate (VI) synthesis formula uses more than the stoichiometric requirement of hypochlorite (Standard Chlorine Formula). For applications requiring low chlorine residual effluent quality, the Low Chlorine Formula …
-
Modelling water quality in tropical water distribution systems
… quantify key water quality parameters, such as chlorine concentration, flow velocity, pH, and biofilm growth, and evaluate the influence of these parameters on corrosion and iron release in a tropical drinking water distribution system. The approach of this study was split into three (3) …
-
A Pilot-scale Evaluation of Soluble Manganese Removal Using Pyrolucite Media in a High-Rate Adsorptive Contactor
… constant associated with Mn oxidation by free chlorine. The research work included an 18-week pilot-plant study conducted at a water treatment facility in Newport News, VA. A contactor column loaded with 27â of pyrolucite media was operated at varying applied water conditions. Hydraulic loading …
-
Validation of Post-Harvest Wash Process to Prevent Cross-Contamination in Leafy Green Processing
… of sanitizers (sodium hypochlorite 200-ppm total chlorine, chlorine dioxide50 ppm, peracetic acid70 ppm, and Food Freshly 50-500 to prevent cross-contamination during leafy green wash process. From the range of sanitizers tested it was found that peracetic acid or chlorine dioxide reduced …
-
Thin Film Composite Membranes Derived from Interfacial Polymerization for Nanofiltration and Pervaporation Applications
… of 24.5 L/(m2.h) were obtained at a feed solute concentration of 500 ppm and transmembrane pressure of 0.8 MPa gauge. In another approach, monomeric amine piperazine (PIP) was embedded into the polymeric amine PEI as the amine reactant. Membranes with a single-ply polyamide layer were produced by …