Chlorine Demand Shows Thresholds and Hierarchy with Source Water Quality at Beaver Lake, Arkansas
… water quality in Beaver Lake on the amount of chlorine (Cl) needed to develop decision support system to help guide chlorination practices in pre-treatment of source water. Chlorine demand assays were performed on water samples from Beaver Lake collected from the intake structure at Beaver …
-
Quantitative Structure-Property Relationships for Predicting Chlorine Demand and Disinfection Byproducts Formation in Drinking Water
… may not always have linear relationships with chlorine demand and DBPs formation which make structure-based models more attractive to study. In this dissertation, Quantitative Structure-Property Relationship (QSPR) models which make use of structural properties of individual molecules were …
-
Ozonation of a Municipal Surface Water Supply to Reduce Trihalomethanes, Odor, Chlorine Demand, and Organics
… of ozonation on trihalomethane formation, odor, chlorine demand, and organics. Spectrophotometric characteristics were analyzed for surrogate parameter studies. Following a preliminary study based on trihalomethane reduction, ozone dosages of 0, 4, 8, and 12 mg/1 were applied to raw water at …
-
Ozonation of a Municipal Surface Water Supply to Reduce Organics and Chlorine Demand and Enhance Flocculation
… and produce tastes, odors, increased chlorine demand, and reduced flocculation efficiency. In this research ozone was applied to raw water through use of a pilot plant to determine the effects of ozonation on organics, chlorine demand, and flocculation. Ancillary studies were conducted …
-
An investigation of the methods used in the determination of the chlorine demand of settled sewage
The chlorine demand correlations, which exist in the settled domestic sewage at the V.P.I. Sewage Treatment Plant between the limits of one and seven ppm, of applied chlorine dosage were determined.
-
Use of THMFP, TOC and chlorine demand as control parameters for monitoring the performance of an ozonation/FBT system
Thesis (M.S.)--Michigan State University. Department of Civil and Environmental Engineering, 1997
-
Application of Advanced Oxidation Process as a Pre-Oxidation Step for Spent Lettuce Wash Water and for Decontaminating Fruit and Sliced Mushrooms
… Finally, an AOP based process for reducing the chlorine demand of spent lettuce wash water was developed. The pre-oxidation treatment reduced the chlorine demand of water by 20 ppm and enhanced the stability of hypochlorite within the wash water. Collectively, the research has demonstrated the …
-
Validation of Post-Harvest Wash Process to Prevent Cross-Contamination in Leafy Green Processing
… of sanitizers (sodium hypochlorite 200-ppm total chlorine, chlorine dioxide50 ppm, peracetic acid70 ppm, and Food Freshly 50-500 to prevent cross-contamination during leafy green wash process. From the range of sanitizers tested it was found that peracetic acid or chlorine dioxide reduced …
-
Performance Of Activated Filter Media® (Afm) In Drinking Water Treatment Systems
… dissertation study were total organic carbon, chlorine residual, turbidity, UV254, total trihalomethane formation, filter headloss development, and filter runtime development. Results from the study indicated that AFM could be a viable replacement for traditional sand while maintaining water …
-
Ozone Pilot Plant Studies of Six Municipal Water Supplies
… dosages and contact times for reducing odors, chlorine demand, organic carbon, trihalomethanes, iron, and manganese. Tests were also done to assess flocculation effects on those plants that depended on settling. The results were utilized to establish capital and operating costs. Test parameters …
-
Machine Learning Applied to Chlorine Residual Data
Chlorine disinfection systems are ubiquitous in drinking water treatment plants and provide a method for reliable, safe, potable water. The concentration of free chlorine residual (FCR) leaving drinking water treatment plants must be between a federally regulated margin of 4.00 and 0.20 mg/L as …
-
Achieving safe free residual chlorination at point-of-use in emergencies: a modelling approach
… showed varying recommendations for the initial chlorine dose and many did not consider chlorine decay during water transportation and storage for up to 24 hours. The main objective of this thesis is to develop a tool for humanitarian staff to accurately determine the initial chlorine dose for …
-
A comparison of two membrane filter techniques for the enumeration of total coliforms in potable water
… techniques on coliforms exposed to varying chlorine residuals and contact times. An enrichment-step membrane-filter method (E-MF) involved the incubation of a filtered water sample on lauryl tryptose plus 1.5 per cent agar for two hours at 35°C prior to transfer of the filter to LES-Endo …
-
The Effects of PET-Lined and Epoxy-Coated Lead and Copper Service Lines on Metals Leaching, Total Organic Carbon, and Chlorine Residual in Drinking Water
… on water quality through chemical leaching and chlorine consumption. Fill-and-dump experiments were performed to determine the impact of a commercially available epoxy coating and poly(ethylene terephthalate) (PET) liner on water quality in lead and copper pipes. Forty-five-inch-long pipe …
-
Determination of the N-Terminal Amino Acid Residues on Polypeptides in Secondary Wastewaters
… do not make a significant contribution to the chlorine demand of organic amino nitrogen in wastewaters.
-
Ozonation of a Municipal Surface Water Supply to Reduce Trihalomethane Formation and the Use of Surrogate Parameters to Predict Trihalomethane Concentrations
… agreed that THMs are formed by the reaction of chlorine with organic precursors, particularly humic substances, in the water. Thus, since surface waters typically are higher in organics, surface water supplies are usually higher in halogenated organics. The factors controlling production of THMs …
-
Performance and microbial community structure of Midwestern groundwater pretreatment reactors
… recently as water utilities seek to minimize chlorine demand and potential disinfection byproduct formation. Many plants are forced to chlorinate before primary filtration in order to meet disinfection requirements, so a pretreatment configuration is the one of the few feasible locations for …
-
Synergy of Alum and Chlorine Dioxide for Curbing Disinfection Byproduct Formation Potential at Central Arkansas Water
… has begun retrofitting their two plants to use chlorine dioxide as an alternative primary disinfectant followed by free chlorine secondary disinfection in the distribution system. In this study, fluorescence parallel factor (PARAFAC) analysis was combined with free chlorine simulated …
-
Field study of performance of rectangular chlorine contact tanks
… of the efficiency of three types of rectangular chlorine contact tanks. Efficiency of the tanks was evaluated in terms of the type of initial mixing of the chlorine and fluid, location and configuration of the inlet and outlet structures, the influence of baffles and the effect of sludge …
-
Formation of Trihalomethanes (THMs) as Disinfection by-Products (DBPs) when Treated Municipal Wastewater is Disinfected with Sodium Hypochlorite
… for disinfection. However, hypochlorite (chlorine) disinfection has disadvantages as well, such as the production of disinfection by-products (DBPs) such as trihalomethanes (THM) and haloacetic acids (HAAs), which may have adverse impacts on the quality of surface waters that receive the …