Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 6 of 6 for “"Chronic implants"”.
-
Molecular investigation of polypyrrole and surface recognition by affinity peptides
… signals of the native environment. To date, all chronic implants incorporating electrical conductivity degrade in performance over time as the foreign body reaction and subsequent fibrous encapsulation isolate them from the host tissue. Our goal is to develop a peptide-based interfacial …
-
Active surgical positioning device for a cochlear implant electrode array
Cochlear implants have been of great benefit in restoring auditory function to individuals with profound bilateral sensorineural deafness. The implants are used to directly stimulate auditory nerves and send a signal to the brain that is then interpreted as sound. This project focuses on the …
-
SPEECH BRAIN-COMPUTER INTERFACES FOR THE RESTORATION OF CONTROL AND COMMUNICATION
… thesis investigates the feasibility of using a chronically implanted electrocorticographic (ECoG) BCI to restore functional control and communication for individuals with severe paralysis. We present work from a clinical trial in which a participant with amyotrophic lateral sclerosis (ALS) used …
-
Quantifying High Dimensional Recordings of Neural Surface Potentials
<p>Chronically reliable neural implants are needed to provide long lasting, high fidelity interfaces for clinical use and for basic science. Minimally invasive implants, such as micro-electrocorticographic arrays (µECoG), have been proposed in this field to minimize immune response and glial …
-
Development and Validation of Software for Modeling Vagus Nerve Stimulation Across Species
… inter-individual variability for both acute and chronic implants. For B fibers, our small-diameter fiber model underestimated threshold and saturation for pulse widths >0.25 ms. Our models of pig VNS consistently captured the range of in vivo thresholds across all measured nerve and physiological …
-
Chronic inflammation surrounding intra-cortical electrodes is correlated with a local, neurodegenerative state
… is hampered by a lack of reliability in chronic recordings, independent of the type of electrodes used. The dominant hypothesis has been that astroglial scar electrically impedes the electrodes. However, recent studies suggest that the impedance changes associated with the astroglial scar …