Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 23 for “"Circulatory support devices"”

  1. Virtual Implantation of Mechanical Circulatory Support Devices

    Our group previously described successful use of virtual implantation of the 70cc Total Artificial Heart (TAH) to predict safe placement in small-size patients not meeting standard fit criteria. With the new 50cc TAH, there is an opportunity for broader use of the TAH device in pediatric patients …

    ohiolink Repository record for Virtual Implantation of Mechanical Circulatory Support Devices (opens in a new tab)

  2. Cardiac Output Improvement in Mechanical Circulatory Support Devices

    Mechanical circulatory support devices (MCSDs) have gained widespread clinical acceptance as an effective heart failure (HF) therapy. The concept of harnessing the kinetic energy (KE) available in the forward aortic flow (AOF) is proposed as a novel control strategy to further increase the cardiac …

    ndsu Repository record for Cardiac Output Improvement in Mechanical Circulatory Support Devices (opens in a new tab)

  3. Design And Modeling Of Self-Sufficient Mechanical Circulatory Support Devices

    Cardiovascular diseases often require mechanical circulatory support devices to restore adequate blood flow in advanced stages. Despite significant technological progress, most existing assist systems rely on external power sources and remain susceptible to hemocompatibility-related complications. …

    metu Repository record for Design And Modeling Of Self-Sufficient Mechanical Circulatory Support Devices (opens in a new tab)

  4. The importance of pulsatility in modern mechanical circulatory support devices

    … inadequate solution. Modern durable mechanical circulatory support (MCS) devices, such as ventricular assist devices (VADs) can provide bridging therapy to transplantation, or alternatively function as a destination therapy. These devices lack pulsatility which has important physiological …

    unsw Repository record for The importance of pulsatility in modern mechanical circulatory support devices (opens in a new tab)

  5. A comparison of outcomes among the patients with mechanical circulatory support devices and heart transplantation /

    … advanced therapies such as durable mechanical circulatory support, particularly left ventricular assist devices, and orthotopic heart transplantation must be considered. Heart transplantation has traditionally been regarded as the gold-standard treatment for eligible patients, but its use is …

    vilnius Repository record for A comparison of outcomes among the patients with mechanical circulatory support devices and heart transplantation / (opens in a new tab)

  6. Expanding the Performance Envelope of the Total Artificial Heart: Physiological Characterization, Development of a Heart Failure Model, And Evaluation Tool for Mechanical Circulatory Support Devices

    … shortages in available donor hearts, mechanical circulatory support (MCS) has emerged as a life-saving treatment for advanced stage HF. With growth in MCS use, a clinical and developmental need has emerged for a standard characterization and evaluation platform that may be utilized for …

    arizona-thes Repository record for Expanding the Performance Envelope of the Total Artificial Heart: Physiological Characterization, Development of a Heart Failure Model, And Evaluation Tool for Mechanical Circulatory Support Devices (opens in a new tab)

  7. Kardiogeninis šokas: Kada naudoti pagalbinius prietaisus? /

    … of patients, necessitating the use of mechanical circulatory support devices. An ideal mechanical circulatory device is described as a tool that ensures effective and reliable circulatory support, is easily and quickly deployed, is typically managed and monitored during application, and has few …

    vilnius Repository record for Kardiogeninis šokas: Kada naudoti pagalbinius prietaisus? / (opens in a new tab)

  8. Acquired Platelet And Neutrophil Dysfunction Due To High Mechanical Shear Stress

    … complications. LVADs and other mechanical circulatory support devices induce damage to blood cells and plasma components due to the high mechanical shear stress (HMSS) generated. Therefore, there must be a link between LVAD-induced cellular damage and the adverse events experienced in LVAD …

    maryland Repository record for Acquired Platelet And Neutrophil Dysfunction Due To High Mechanical Shear Stress (opens in a new tab)

  9. SURFACE ZETA POTENTIAL AS A BIOMARKER FOR MONITORING HUMAN RED BLOOD CELLS

    … by physiologic circulation and mechanical circulatory support devices. Conventionally, erythrocyte sedimentation rate (ESR) has been used to quantify surface charge-induced RBC aggregation, by measuring the time required for RBCs to settle at the bottom of a glass tube. However, ESR cannot …

    wfu Repository record for SURFACE ZETA POTENTIAL AS A BIOMARKER FOR MONITORING HUMAN RED BLOOD CELLS (opens in a new tab)

  10. Acute myocardial infarction due to left main coronary artery occlusion: state of the art

    … of early reperfusion with PCI and mechanical circulatory support devices use, the mortality rate in this subgroup of patients remains high. This review summarizes the epidemiology, clinical presentation, electrocardiographic and angiographic findings, and revascularization strategies of AMI …

    porto Repository record for Acute myocardial infarction due to left main coronary artery occlusion: state of the art (opens in a new tab)

  11. Ενεργειακή διερεύνηση και προσομοίωση της μηχανικής υποστήριξης της ανεπαρκούσης καρδιάς με αποδοτικό σύστημα

    … transplantation or implantation of a mechanical circulatory support device. Cardiac transplantation is considered the gold standard treatment even though it is accompanied with serious complications. The management of these complications will benefit, however, only the cardiac graft recipients …

    greece Repository record for Ενεργειακή διερεύνηση και προσομοίωση της μηχανικής υποστήριξης της ανεπαρκούσης καρδιάς με αποδοτικό σύστημα (opens in a new tab)

  12. Kardiogeninis šokas ir pagalbinės kraujotakos priemonės /

    … the recent literature on cardiogenic shock and circulatory support. This work reviews the clinical presentation and management of cardiogenic shock, focusing on the use of circulatory support in clinical practice and the benefits on survival. A literature review was performed using PubMed and …

    vilnius Repository record for Kardiogeninis šokas ir pagalbinės kraujotakos priemonės / (opens in a new tab)

  13. Physical Forces-Mediated Platelet Activation: Devices and Effects with an Emphasis on Vibro-Acoustics

    … stimuli originating from snoring or mechanical circulatory support devices (MCSD) or an increase of laminar shear stress due to the narrowing of the vasculature. The extent to which these physical forces stimulate platelets is still unknown. With the development of an in-vitro vibro-acoustic …

    arizona-thes Repository record for Physical Forces-Mediated Platelet Activation: Devices and Effects with an Emphasis on Vibro-Acoustics (opens in a new tab)

  14. Viscoelastic properties of pediatric blood

    The performance of pediatric circulatory support devices depends on the properties of pediatric blood. This study reports the measurement of the viscoelastic properties of pediatric blood at 37°C [body temperature]. The results were compared with adult viscoelastic properties at the same …

    louisville Repository record for Viscoelastic properties of pediatric blood (opens in a new tab)

  15. JOINT MICROFLUIDIC ASSESSMENT OF LOCAL SHEAR AND SHEAR HISTORICAL EFFECTS ON THROMBOSIS: APPLICATIONS TO HEART-ASSIST DEVICES AND HYPERINFLAMMATORY STATES

    … yet undesired feature of heart-assist devices is elevated shear rates throughout the flow circuit. Blood components rely on deviations from physiological shear to sense bleedings events and trigger thrombosis. As a result, thrombotic complications are common in patients with circulatory …

    cornell Repository record for JOINT MICROFLUIDIC ASSESSMENT OF LOCAL SHEAR AND SHEAR HISTORICAL EFFECTS ON THROMBOSIS: APPLICATIONS TO HEART-ASSIST DEVICES AND HYPERINFLAMMATORY STATES (opens in a new tab)

  16. Coronary and myocardial physiology of left ventricular unloading

    … and treatment of cardiogenic shock. Mechanical circulatory support devices deliver varying degrees of ventricular unloading through differing mechanisms of action. Despite their physiological promise of improved myocardial supply and demand, they have failed to make an impact on patient outcomes …

    kings Repository record for Coronary and myocardial physiology of left ventricular unloading (opens in a new tab)

  17. Enhanced implantable device evaluation using a hardware-in-the-loop circulatory simulator

    … does the need and use of implantable mechanical circulatory support devices, such as ventricular assist devices (VADs) and total artificial hearts (TAHs), for patient treatment. These devices assist the failing heart by taking over the blood pumping process either partially or completely and must …

    texas Repository record for Enhanced implantable device evaluation using a hardware-in-the-loop circulatory simulator (opens in a new tab)

  18. Evaluation of a direct systolic cardiac augmentation device on a canine heart during global postischemic dysfunction

    … may be detrimental to the myocardial tissue or circulatory support devices which may be inadequate or require extensive surgical placement;Six mongrel dogs were anesthetized and cardiac fibrillation was induced with a low-voltage alternating current. The subjects were allowed to fibrillate for a …

    iastate Repository record for Evaluation of a direct systolic cardiac augmentation device on a canine heart during global postischemic dysfunction (opens in a new tab)

  19. Feasibility of subcutaneous ECG leads for synchronized timing of a counterpulsation device.

    Background: Emerging circulatory support devices that operate in counterpulsation to the native heart require synchronized timing of device ejection and filling on a beat-to-beat basis with the native heart using a patient's ECG. Surface leads are commonly used for short-term patient monitoring but …

    louisville Repository record for Feasibility of subcutaneous ECG leads for synchronized timing of a counterpulsation device. (opens in a new tab)

  20. Investigation of the use of electro active polymer as a paediatric VAD driver

    … developed to address this issue by providing support to the failing heart, both as a permanent solution and as a bridge to recovery. These options are called Mechanical Circulatory Support Devices, a particular branch of these devices is the Ventricular Assist Devices, which have been under …

    strathclyde Repository record for Investigation of the use of electro active polymer as a paediatric VAD driver (opens in a new tab)

Page 1 of 2