Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 12 of 12 for “"Clean Air Delivery Rate"”
-
Experimental Testing and Performance Analysis of “Room Air Cleaners”
“HMI industries” are the manufacture of the air cleaners and vacuum cleaners, in which a solution is adapted for the current model of the volute to the new design of the volute in order to calculate the “Clean Air Delivery rate” and qualify for the “Energy Star requirements”. For the above model to …
-
Multizone Modeling of Airborne Quanta Transmission and CO2-based Ventilation Designs for Assessing Indoor Exposures
… the critical role of ventilation in controlling airborne respiratory infections indoors. During this period, inadequate ventilation systems and improper operations in densely populated public spaces were frequently linked to outbreaks and superspreading events, heightening concerns over indoor …
-
Indoor air purification using heterogeneous photocatalytic oxidation
… encountered when implementing PCO for indoor air purification include ineffective immobilization, low degradation efficiency and lack of UV light source indoors. This project experimentally investigated the photocatalyst immobilization method as well as visible-light induced PCO of gaseous …
-
Air quality in care facilities: Possibly infectious particles
This study investigates how air cleaning reduces airborne particle and bacterial concentrations in healthcare environments, aiming to lower infection risk without increasing mechanical ventilation rates. The study combines laboratory experiments, infection risk modelling, and field measurements in …
-
Evaluation on the performance of portable air cleaners by particle sizes in residences
<p>Nowadays, with the increased concern of Indoor Air Quality, portable air cleaner is commonly utilized to treat air in indoor environments. Testing standards for air cleaner in evaluating their performances are also in response to their rapid development. However, all of them are chamber test …
-
Efficiency of Portable HEPA Air Purifiers against Traffic Related Ultrafine Particles
… conditions such as asthma. HEPA filtered air purifiers can reduce the concentrations of these particles, and therefore provide health benefits to the users. The Association of Homeowner Appliance Manufacturers (AHAM) tests the purifiers in terms of Clean Air Delivery Rate (CADR) for …
-
Mitigation of airborne contaminants in classrooms and meeting rooms with ventilation, air cleaning, and structural measures
Airborne contaminant transmission in indoor environments poses challenges to occupant health, safety, and comfort, particularly in densely occupied spaces. This dissertation investigates ventilation- and air-cleaning-based strategies to reduce airborne contaminant exposure, with a focus on …
-
Reducing Workers' Exposures to Chemicals and Dust in Nail Salons Using Local Exhaust Ventilation Systems
… acetone vapor and acrylic nail dust were generated at finger level using realistic work activities in a lab setting and exposures measured in the technician's breathing zone using real-time air monitoring. The dust was generated by grinding acrylic nails using a standard salon tool and typical …
-
Improved Method of Evaluating Gas-Phase Air Cleaners Considering Adsorption and Desorption Mechanisms To and From Internal Test Chamber Surfaces
Portable air cleaners are playing an increasingly important role in managing indoor air quality in response to pressing issues like wildfire smoke events. Smoke is a complex mixture of gases and particulate matter; while established test methods exist for particulate matter, the dynamic behavior of …
-
Using Sensors to Investigate the Effectiveness of Portable Air Filtration for Reducing Particle Exposures: Implications for Community Congregate Settings
… This study addresses critical aspects of indoor air quality management with a focus on community congregate settings through a combination of laboratory and field studies. We aimed to 1) Develop a standardized laboratory protocol for characterizing and calibrating the performance of low-cost …
-
Developing and Testing Low-Cost Air Cleaners for Safer Spaces During Wildfires
Air cleaning reduces indoor exposure to fine particulate matter (PM2.5) during wildfire events. However, resource and cost restraints may limit access to air cleaning during such an event, as both commercial devices and the high-rated MERV filters that homemade assemblies typically rely upon tend …
-
PHIREWISE: Public Health Impact and Response on Wildfire Exposure and Health Support and Evaluation
… and Health Support and Evaluation Lilian Liu Chairs of the Supervisory Committee:Elena Austin, ScD, MS Edmund Seto, PhD, MS Department of Environmental and Occupational Health Sciences Background: Extreme events including wildfire (WF) and wildfire smoke (WFS) have increased in frequency, …