Infrared thermography for non-destructive identification of reinforcement in concrete
… specimens containing bars of various sizes and clear cover. The temperature measurements with infrared probes on the surface of the specimens clearly identified the bars up to one inch clear cover. More refined processing and imaging technique are needed to identify bars at larger depth.
-
Impact of Specification Changes on Chloride Induced Corrosion Service Life of Virginia Bridge Decks
… apparent diffusion coefficient, and clear cover depth. Several ranges of the chloride corrosion initiation concentration, as determined from the available literature, were investigated. The time to first repair and subsequent rehabilitation predicted by the stochastic model is shorter …
-
Application of Ultra-High Performance Concrete in Prefabricated Bridge Element Connections for Accelerated Bridge Construction
… in the 54 tested pull-out specimens include clear cover, embedment length, and strand diameter (dPT). It was observed that specimens that experienced strand failure had an embedment length of at least 24×dPT or clear cover distance of 2.17×dPT. The third study investigates the behavior of …
-
Subsidence Cracking of Concrete Over Steel Reinforcement Bar in Bridge Decks
… reinforcing steel resulting in spalling of the cover concrete. Concrete specimens with 16 mm (# 5) diameter bars were cast with various cover depths, bar spacing and two concrete mixture types to determine the influence that epoxy coated reinforcement, cement type and bar spacing may have on the …
-
Effect of Environmental Conditions and Structural Design on Linear Cracking in Virginia Bridge Decks
… M.C., 2002). Since linear cracking in concrete cover can potentially accelerate chloride ingress to the depth of the reinforcing steel, there is reason to believe that severity of deck cracking can significantly influence the time to first repair and/or rehabilitation of the bridge deck. Surface …
-
Finite element modeling of thin fiber reinforced concrete pavements
… the thin concrete pavement due to insufficient clear cover. For such pavements, structural fibers are a good option for increasing joint performance or load transfer efficiency, as well as reducing faulting. However, only limited studies are available in understanding the contribution of …
-
Service and Ultimate Limit State Flexural Behavior of One-Way Concrete Slabs Reinforced with Corrosion-Resistant Reinforcing Bars
… Grade 60 with CRR, a reduction of concrete top clear cover, and a reduction in bar quantities in the bridge deck top mat influences flexural performance at service and ultimate limit states. Moment-curvature predictions from the computer-based sectional analysis program Response 2000 were …
-
Structural health monitoring of Attridge Drive overpass
… of the bridge deck, resembling the spalled clear cover of concrete deck of the overpass. Five different VBDD techniques were evaluated, including the Change in Mode Shape, Change in Flexibility, Change in Mode Shape Curvature, Change in Uniform Flexibility Curvature and Damage index methods. …
-
Designing and Testing Connections for Precast Ultra-High-Performance Concrete Structural Components for Modular Houses
… embedment lengths (6db, 8db, and 10db) and clear covers (0.75db through 1.75 db). In the analysis, the general behaviour of the specimens is examined to determine whether any of the varying parameters affect the behaviour. A more thorough analysis of the relationship between the embedment …
-
ANCHORAGE OF HEADED REINFORCING BARS IN CONCRETE
… bars was 1.67, 2.33, or 3.53 bar diameters db; clear concrete cover to the bars was 2 in.; concrete compressive strengths averaged 6,360 and 10,950 psi; and stresses in the bars at failure ranged from 75,010 to 83,560 psi. For the beam-column joints subjected to reversed cyclic loading, headed …
-
Development of an Economical Ultra-High-Performance Concrete Mix Using Local Materials
… in critical infrastructure projects, such as nuclear waste containment facilities, precast structural connection joints, bridge girders, and bridge deck systems. However, the high cost of commercially available, pre-bagged UHPC remains a significant obstacle. This study aims to develop a …
-
Experimental Study of Novel BCSA SCC Repair Materials and Implications on Corrosion in BCSA Concrete Structures
… decreasing the water to cement ratio, increasing cover, and the use of surface sealers. The study found that durability testing of alternative cement concrete should be done considering the maturity of the concrete, rather than arbitrarily selecting a testing age based on PC based standards. …
-
Correlation of corrosion measurements and bridge conditions with NBIS deck rating
… subjective application by the field inspectors. Clear cover depths, resistance, corrosion potentials, linear polarization data, as well as environmental exposure and structural data were collected from a sample of 38 bridge decks in the Commonwealth of Virginia. These structures were further …
-
Repair and strengthening of Pre-1970 reinforced concrete corner beam-column joints using CFRP composites
… by adding a #7 reinforcing bar within the clear cover at the column inside corner and by externally bonding multiple layers of carbon fabric to form a carbon-epoxy retrofit system. Two other specimens, one of which had a significantly lower concrete compressive strength, were strengthened …
-
Lap Splicing of Large High-Strength Steel Reinforcing Bars
… bars is advantageous in large structures like nuclear power plants. Nevertheless, ACI 318-19 prohibits tension lap splices for bars larger than No. 11 [36 mm] because limited test data are available. Eleven large-scale reinforced concrete beams with tension lap splices were tested under …
-
Hybrid structures using ultra high performance concrete and normal concrete for bridge applications
… of 8 db (db -diameter of rebar) in UHPC with 3db clear cover was found to be sufficient to yield a Grade 60 mild steel reinforcement. A hybrid prestressed girder concept utilizing UHPC in the end zones of the girder with normal concrete in the remainder of the girder was proposed for a long-span …