Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"Closed Conduit"”.

  1. Safe closed conduit fish passage

    … understanding of potential fish injuries in closed conduit systems more broadly. Systematic experiments assessed risk arising from hydrodynamic effects at pipe components including smooth entrances, expansions, contractions and 90-degree bends. Using Lagrangian sensors complemented with live …

    unsw Repository record for Safe closed conduit fish passage (opens in a new tab)

  2. Automatic Control of a Closed Conduit Cutback Irrigation System

    The total supply of water on the earth today is about the same as it was thousands of years ago. It is estimated that by the year 2020, 1,380 billion gallons of water will be used every day to satisfy the needs of 468 million people in the United States. Priorities will therefore have to be …

    sdstate Repository record for Automatic Control of a Closed Conduit Cutback Irrigation System (opens in a new tab)

  3. Laboratory Investigation of a Model Multi-tube Closed Conduit Spillway

    Renewed interest in the hydraulic performance of closed conduits is evidenced by the number of studies reported since 1950. The hydraulics of closed conduit spillways is not as simple as previous thoughts had indicated and is a reason for the renewed interest. Another reason is that many of these …

    sdstate Repository record for Laboratory Investigation of a Model Multi-tube Closed Conduit Spillway (opens in a new tab)

  4. Comparison of Theoretical, Laboratory and Field Discharge Ratings for a Closed Conduit Spillway

    … metal end section on the precast concrete conduit. (3) To investigate the three types of flow; weir flow, slug flow, and full-pipe flow; generally assumed to exist in this type of structure. (4) To make theoretical, laboratory, and field comparisons of the existing closed conduit spillway …

    sdstate Repository record for Comparison of Theoretical, Laboratory and Field Discharge Ratings for a Closed Conduit Spillway (opens in a new tab)

  5. The Effect of Wave Formation on Open Channel Flow in a Triangular Closed Conduit

    … for water to be delivered by means of open or closed conduits. Analysis of the flow within these conduits is decided into two categories, open-channel flow and pipe flow. Lembke observed the transition from part-flow to full-flow in steep circular drains; he noted five flow regimes for this …

    sdstate Repository record for The Effect of Wave Formation on Open Channel Flow in a Triangular Closed Conduit (opens in a new tab)

  6. Design of the Distribution Portion for an Automated Closed Conduit Cut-back Furrow Irrigation System

    The research presented herewith was undertaken to define more accurately the design components for the distribution system. The specific objectives of this research are as follows: 1. To investigate the discharge characteristics for nonregulating bored outlets. 2. To determine the factors …

    sdstate Repository record for Design of the Distribution Portion for an Automated Closed Conduit Cut-back Furrow Irrigation System (opens in a new tab)

  7. Characteristics of dividing and combining flows

    … lateral slot located in a rectangular conduit. Existing theoretical solutions to this problem are based on free streamline theory. The test results provide data to verify the predictions of the theoretical model related to the dependence of the slot discharge coefficient on discharge …

    concordia Download PDF for Characteristics of dividing and combining flows (opens in a new tab)

  8. Air Demand in Free Flowing Gated Conduits

    … physical experimental setup of a circular, gated closed conduit was built at the Utah Water Research Laboratory (UWRL). Setup configurations were modified and data were measured to aid in the study of physical variables on air demand. It was determined that gate opening, gate and water surface …

    utahstate Repository record for Air Demand in Free Flowing Gated Conduits (opens in a new tab)

  9. Modeling of hydraulic transients in closed conduits

    … variations in the flow field in pressurized (closed-conduit) systems. For example, changes in velocity from valve closures or pump operations cause pressure surges that are propagated away from the source throughout the pipeline. The elasticity of the pipe boundaries and the compressibility of …

    colostate Repository record for Modeling of hydraulic transients in closed conduits (opens in a new tab)

  10. Theoretical Determination of Subcritical Sequent Depths for Complete and Incomplete Hydraulic Jumps in Closed Conduits of Any Shape

    … sequent depth from momentum theory. In closed conduits, however, outlet submergence may fill the conduit entirely before the expected sequent depth is reached. This is called an incomplete or pressure jump (as opposed to a complete or free-surface jump), because pressure flow conditions …

    byu Repository record for Theoretical Determination of Subcritical Sequent Depths for Complete and Incomplete Hydraulic Jumps in Closed Conduits of Any Shape (opens in a new tab) Download PDF for Theoretical Determination of Subcritical Sequent Depths for Complete and Incomplete Hydraulic Jumps in Closed Conduits of Any Shape (opens in a new tab)

  11. Microbial Communities in Septic Tank Anaerobic Digesters and Their Interactions with Digester Design and Chemical Environment

    … tanks and septic tanks equipped with a novel closed-conduit tube called the InnerTubeTM. Wastewater was sampled along the length of each digester to explore the microbial community stratification during the anaerobic digestion treatment process. Additionally, the effect of effluent, aerobic …

    mcmaster Repository record for Microbial Communities in Septic Tank Anaerobic Digesters and Their Interactions with Digester Design and Chemical Environment (opens in a new tab)

  12. The Effects of Upstream Straight Pipe Length on Magnetic Flow Meter Accuracy

    In closed conduit water systems, being able to accurately measure flow is absolutely essential. For many meter designs, including electromagnetic induction meters (also known as magnetic flow meters), the greatest accuracy is achieved when the device is calibrated correctly. Optimal meter accuracy …

    utahstate Repository record for The Effects of Upstream Straight Pipe Length on Magnetic Flow Meter Accuracy (opens in a new tab)

  13. Damping in Transient Pressurized Flows

    … closure in a simple piping system in pressurized closed conduit using Bayesian inference is quantified. The joint probability density of the model parameter is estimated based on experimental results published in the literature as well as from experiments performed at the University of South …

    south-carolina Repository record for Damping in Transient Pressurized Flows (opens in a new tab)

  14. Sediment Transport Impacts Upon Culvert Hydraulics

    … sediment transport in both open channel and closed conduit applications is provided to develop a foundation of knowledge to pursue further research in this area. This literature review summarizes the current body of scientific knowledge that is applicable to sediment transport in culverts. …

    utahstate Repository record for Sediment Transport Impacts Upon Culvert Hydraulics (opens in a new tab)

  15. Air Demand in Low-Level Outlet Works

    … dams have a low-level outlet that consists of a closed conduit through the dam with a slide gate or valve to regulate flow. These outlets are used mainly for irrigational purposes but also for flushing the reservoir and controlling the reservoir elevation. When discharging through the low-level …

    utahstate Repository record for Air Demand in Low-Level Outlet Works (opens in a new tab)

  16. Analytic and Experimental Studies of a True Airspeed Sensor

    … in a frequency counter. The measurement for both closed conduit tests and wind tunnel tests were recorded. A computer program was developed for obtaining the numerical solution to the theoretical model. The parameters described the sensor geometry were introduced into the calculations. …

    odu Repository record for Analytic and Experimental Studies of a True Airspeed Sensor (opens in a new tab)

  17. Understanding the largest-scale explosive volcanism at Mt. Taranaki, New Zealand : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Earth Science, Massey University, Palmerston North, New Zealand

    … pumice gradients by magma stalling in upper conduit levels. Three eruption onset scenarios were developed from this work: a) initial closed-conduit decompression by vent unroofing and domecollapse, b) transient open and clogged conduits produced by repeated plugging-and bursting of chilled or …

    massey Repository record for Understanding the largest-scale explosive volcanism at Mt. Taranaki, New Zealand : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Earth Science, Massey University, Palmerston North, New Zealand (opens in a new tab)

  18. Turbulence characteristics of counter flowing free jets

    … used to form the jet located at the center of a closed conduit that had a square cross section. The results show that the penetration length varies linearly with the ratio of the jet velocity to the main flow velocity that is denoted by R. Axial and radial velocity components were measured …

    concordia Download PDF for Turbulence characteristics of counter flowing free jets (opens in a new tab)

Page 1 of 2