Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 32 for “"Closed conduit"”

  1. Safe closed conduit fish passage

    … understanding of potential fish injuries in closed conduit systems more broadly. Systematic experiments assessed risk arising from hydrodynamic effects at pipe components including smooth entrances, expansions, contractions and 90-degree bends. Using Lagrangian sensors complemented with live …

    unsw Repository record for Safe closed conduit fish passage (opens in a new tab)

  2. Automatic Control of a Closed Conduit Cutback Irrigation System

    The total supply of water on the earth today is about the same as it was thousands of years ago. It is estimated that by the year 2020, 1,380 billion gallons of water will be used every day to satisfy the needs of 468 million people in the United States. Priorities will therefore have to be …

    sdstate Repository record for Automatic Control of a Closed Conduit Cutback Irrigation System (opens in a new tab)

  3. Laboratory Investigation of a Model Multi-tube Closed Conduit Spillway

    Renewed interest in the hydraulic performance of closed conduits is evidenced by the number of studies reported since 1950. The hydraulics of closed conduit spillways is not as simple as previous thoughts had indicated and is a reason for the renewed interest. Another reason is that many of these …

    sdstate Repository record for Laboratory Investigation of a Model Multi-tube Closed Conduit Spillway (opens in a new tab)

  4. Comparison of Theoretical, Laboratory and Field Discharge Ratings for a Closed Conduit Spillway

    … metal end section on the precast concrete conduit. (3) To investigate the three types of flow; weir flow, slug flow, and full-pipe flow; generally assumed to exist in this type of structure. (4) To make theoretical, laboratory, and field comparisons of the existing closed conduit spillway …

    sdstate Repository record for Comparison of Theoretical, Laboratory and Field Discharge Ratings for a Closed Conduit Spillway (opens in a new tab)

  5. The Effect of Wave Formation on Open Channel Flow in a Triangular Closed Conduit

    … for water to be delivered by means of open or closed conduits. Analysis of the flow within these conduits is decided into two categories, open-channel flow and pipe flow. Lembke observed the transition from part-flow to full-flow in steep circular drains; he noted five flow regimes for this …

    sdstate Repository record for The Effect of Wave Formation on Open Channel Flow in a Triangular Closed Conduit (opens in a new tab)

  6. Modeling Flow Dynamics in a Closed Conduit Cave System:Model Cave, Baker Creek Cave System, Nevada

    Flood flow in a closed-conduit cave system is difficult to directly measure, requiringalternative approaches to reconstruct hydraulic conditions, such as using a closed-conduithydraulic model. In this study, cave survey data and scallop measurements were collectedin an epiphreatic lift passage in …

    ohiolink Repository record for Modeling Flow Dynamics in a Closed Conduit Cave System:Model Cave, Baker Creek Cave System, Nevada (opens in a new tab)

  7. Design of the Distribution Portion for an Automated Closed Conduit Cut-back Furrow Irrigation System

    The research presented herewith was undertaken to define more accurately the design components for the distribution system. The specific objectives of this research are as follows: 1. To investigate the discharge characteristics for nonregulating bored outlets. 2. To determine the factors …

    sdstate Repository record for Design of the Distribution Portion for an Automated Closed Conduit Cut-back Furrow Irrigation System (opens in a new tab)

  8. Generation of Supersaturated Total Dissolved Gas at Submerged Hydropower Low-level Outlets

    … bubbles, air demand of a hydraulic jump in a closed conduit with a submerged outlet, and the TDG generation of low-level outlets and its influencing factors. Dissolution of gases from air bubbles to water (mass transfer from air bubbles to water) directly leads to the generation of TDG. To …

    alberta Repository record for Generation of Supersaturated Total Dissolved Gas at Submerged Hydropower Low-level Outlets (opens in a new tab)

  9. Characteristics of dividing and combining flows

    … lateral slot located in a rectangular conduit. Existing theoretical solutions to this problem are based on free streamline theory. The test results provide data to verify the predictions of the theoretical model related to the dependence of the slot discharge coefficient on discharge …

    concordia

  10. Air Demand in Free Flowing Gated Conduits

    … physical experimental setup of a circular, gated closed conduit was built at the Utah Water Research Laboratory (UWRL). Setup configurations were modified and data were measured to aid in the study of physical variables on air demand. It was determined that gate opening, gate and water surface …

    utahstate Repository record for Air Demand in Free Flowing Gated Conduits (opens in a new tab)

  11. Modeling of hydraulic transients in closed conduits

    … variations in the flow field in pressurized (closed-conduit) systems. For example, changes in velocity from valve closures or pump operations cause pressure surges that are propagated away from the source throughout the pipeline. The elasticity of the pipe boundaries and the compressibility of …

    colostate Repository record for Modeling of hydraulic transients in closed conduits (opens in a new tab)

  12. Constrained entropy inequality in water hammer

    <p>A rapid change in the rate of flow in a closed conduit is accompanied by spatial and temporal changes in mass, momentum, energy and entropy. Conventional water-hammer models consist of the one-dimensional mass and momentum equations. This thesis undertakes a rigorous derivation of the …

    hkust Repository record for Constrained entropy inequality in water hammer (opens in a new tab)

  13. Theoretical Determination of Subcritical Sequent Depths for Complete and Incomplete Hydraulic Jumps in Closed Conduits of Any Shape

    … sequent depth from momentum theory. In closed conduits, however, outlet submergence may fill the conduit entirely before the expected sequent depth is reached. This is called an incomplete or pressure jump (as opposed to a complete or free-surface jump), because pressure flow conditions …

    byu Repository record for Theoretical Determination of Subcritical Sequent Depths for Complete and Incomplete Hydraulic Jumps in Closed Conduits of Any Shape (opens in a new tab)

  14. Operation of the water control structures

    … to the downstream parts by assuming that closed conduit at the exit of İncesu Detention Pond can safely convey resultant flood discharges.

    metu Repository record for Operation of the water control structures (opens in a new tab)

  15. Microbial Communities in Septic Tank Anaerobic Digesters and Their Interactions with Digester Design and Chemical Environment

    … tanks and septic tanks equipped with a novel closed-conduit tube called the InnerTubeTM. Wastewater was sampled along the length of each digester to explore the microbial community stratification during the anaerobic digestion treatment process. Additionally, the effect of effluent, aerobic …

    mcmaster Repository record for Microbial Communities in Septic Tank Anaerobic Digesters and Their Interactions with Digester Design and Chemical Environment (opens in a new tab)

  16. The Effects of Upstream Straight Pipe Length on Magnetic Flow Meter Accuracy

    In closed conduit water systems, being able to accurately measure flow is absolutely essential. For many meter designs, including electromagnetic induction meters (also known as magnetic flow meters), the greatest accuracy is achieved when the device is calibrated correctly. Optimal meter accuracy …

    utahstate Repository record for The Effects of Upstream Straight Pipe Length on Magnetic Flow Meter Accuracy (opens in a new tab)

  17. Damping in Transient Pressurized Flows

    … closure in a simple piping system in pressurized closed conduit using Bayesian inference is quantified. The joint probability density of the model parameter is estimated based on experimental results published in the literature as well as from experiments performed at the University of South …

    south-carolina Repository record for Damping in Transient Pressurized Flows (opens in a new tab)

Page 1 of 2