Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 24 for “"Closed-loop testing."”
-
Adaptive insole design to prevent foot ulcers in diabetic neuropathy patients
… passive TPU evaluation, actuator displacement testing, localized pneumatic offloading, and closed-loop sensing-and-actuation testing, all under controlled laboratory conditions. Pressure data was converted to kilopascals and evaluated using heat maps, zone-by-zone comparisons, and measures of …
-
Improved models of electric machines for real-time digital simulation
… application of real-time digital simulators to closed-loop testing of protection relays designed to protect synchronous machines during internal faults. To evaluate the inductances of synchronous machines, a winding function approach was developed in this thesis which is capable of taking into …
-
An FPGA-based Real-time Simulator for the Analysis of Electromagnetic Transients in Electrical Power Systems
… prior to installation and commissioning. Closed-loop testing of a physical control/protection platform, in a real-time simulator environment is practically the only option to safely and thoroughly verify the design integrity and evaluate its functionality and performance. Moreover, a …
-
Formation control for autonomous marine vehicles
The development, implementation, and testing of a leader-follower based robust nonlinear formation controller is discussed in this thesis. This controller uses sliding mode control on the length and angle between the leader and follower vessels to produce the desired formation. A boat model, …
-
Prediction of Lateral Instability and Reducing Rearward Amplification of Autonomous Long Combination Vehicles
… against a simulation model and data from real testing of an A-double. The performance of the controller was tested for different manoeuvres as well as compared against the uncontrolled case, a band-stop filter and a low-pass filter. The results showed that the controller reduced rearward …
-
DESIGN OF A REGENERATIVELY COOLED BI-PROPELLANT ROCKET ENGINE USING ADDITIVE MANUFACTURING
… will need to be qualified with future open and closed-loop testing to evaluate the delivered regenerative cooling effectiveness.
-
Testing Autonomy: Hybrid Scenario Synthesis
… assess autonomous performance under multi-factor testing. Multifactor scenarios employ multiple individual stimuli to rigorously test system responses in complex settings. Static Scenario Testing involves scripted test cases that simulate specific conditions or events. These scenarios represent …
-
Design and Implementation of an Adaptive Cruise Control Algorithm
… team conducted a full range of anything-in-the-loop (XIL) testing. Across model, hardware, and vehicle closed-loop testing, Ohio State identified and resolved numerous potential issues in the controller and its implementation in the vehicle. Additionally, the safety and comfort of the ACC …
-
Composite beam analogy fracture model (CBAFM) : a non-linear fracture mechanics model for concrete
… to the unloading characteristics of a beam. The testing machine need not be very stiff. This makes the testing procedure greatly simplified and makes it suitable not only for the testing laboratory but also for work sites where a closed-loop testing machine is not available. A microcomputer based …
-
Parallel design optimization of multi-trailer articulated heavy vehicles with active safety systems
… (vehicle model) and controllers. To simulate the closed-loop testing maneuvers, a driver model is developed and it is used to drive the virtual vehicle following the prescribed path. Case studies indicate that the PDO method is effective for identifying desired design variables and predicting …
-
Closed-loop throttle control of a hybrid rocket motor.
… such as paraffin wax. This study proposes a closed-loop thrust control scheme for paraffin wax/nitrous oxide hybrid rocket motors using a low-cost ball valve as the controlling hardware element. There are a number of advantages to throttling hybrid rocket motors but the most important is to …
-
Acausal Modeling of Wind Turbines with Validation and Control Studies
… research entities. CRAFTS has undergone rigorous testing, with a particular emphasis on comparison against the industry standard OpenFAST platform (developed by the National Renewable Energy Lab (NREL)) as well as experimental data. Open loop testing scenarios scrutinize the wind turbine dynamic …
-
Real time digital simulation and testing of generator protection elements.
… has greatly improved the simulation and testing of protection studies. In the past, mathematical models were not fully compatible for the representation of the complete synchronous generator stator. The Real Time Digital Simulator (RTDS) has developed a synchronous generator phase domain …
-
Predictive Powertrain Management through Driver Behaviour Recognition
… model built in Simulink used for simulation testing and vehicle development. While addressing the needs of incorporating state-of-the-art technology, this report shows how a LiDAR and camera system can function together as ADAS sensors for vehicle detection and range estimation. Lastly, the …
-
Investigating the performance of generator protection relays using a real-time simulator.
… have been utilized to perform hardware-in-loop testing of protection relays and power system controllers for some years. However, hardware-in-loop testing of generator protection relays has until recently been limited by a lack of suitable dynamic models of synchronous generators in the …
-
Stability Control via In-Wheel Motors of a Solar-Electric Vehicle
… moment control through simulation and real-time testing of the Australian Technology of Networks (ATN) solar car. The ATN solar car competed in the Bridgestone World Solar Challenge (BWSC), 2019; an Australian international competition, where teams drive 3,000 km in custom-designed solar-electric …
-
Out-of-step Protection Using Energy Equilibrium Criterion in the Time Domain
… simulation, hardware implementation and its testing. An out-of-step algorithm is proposed based on equal area criterion in time domain. The equal area criterion in time domain is obtained by modifying the traditional equal area criterion in power angle domain. A single machine infinite bus …
-
Flexure shear response in fatigue of fiber reinforced concrete beams with FRP tensile reinforcement
… the 6" cylinders were performed in standard open-loop testing apparatus and provided load and deflection data up to ultimate strength. The 4" cylinders were tested in closed-loop testing apparatus and provided post-peak load deflection data as well as pre-peak data. After the compressive response …
-
Development of an ultraprecision shaping machine for manufacturing of Stavax lens molds
… the X- and Y-axes have been manufactured for testing. Preliminary testing has shown that the X-axis has at least a stiffness of 60 N/µm in both the degrees of constraint. Movement in the parasitic directions while the axis was being actuated was also tested and showed that the only movement in …
-
Frequency Stability Constrained Grid Operation with High Penetration of Renewables
… N 1 contingency analysis and multi timescale closed loop testing that spans from microseconds to months. By employing the phasor domain dynamic simulations, electromagnetic transient (EMT) simulations, and power hardware in the loop (PHIL) testing, the paper verifies the reliability of the …
Page 1 of 2