Results
Showing 1 to 20 of 83 for “"Co-60"”.
-
Investigation of Megavoltage Digital Tomosynthesis using a Co–60 Source
The ability for megavoltage computed tomography patient setup verification using a cobalt-60 (Co–60) gamma ray source has been established in the context of cobalt tomotherapy. However, it would be beneficial to establish improved cobalt imaging that could be used on more conventional units. In …
-
The Effects of Heat and Co-60 [Gamma]-Radiation on the Oocysts of Eimeria nieschulzi
… of Eimeria nieschulzi Dieben, 1924, a rat coccidium, were exposed to radiation, to heat, or to both in an effort to attenuate the parasite. In addition, studies were conducted on the excystation capabilities and infectivity of treated sporozoites and on their immunogenic potential. These …
-
Monte Carlo modelling and optimisation of flattening filters for a novel Co-60 total body irradiation unit
… uniform dose throughout the whole patient. Most conventional cancer treatment units are not able to provide a sufficiently large uniform radiation field to enable TBI without complex movement of the beam or the patient. Recently, a dedicated Co-60 TBI unit was developed in Canada by BEST …
-
Cell-by-Cell Monte Carlo Modeling of Chromosome Aberrations and Cell Death Induced by 250-kVp X-Rays and Co-60 Gamma Rays
Employing the In-Silico research methodology developed by the Georgia Institute of Technology, an investigation into the interplay between dose rate, chromosome aberrations, misrepairs, and cell survival is outlined. This computational approach utilizes virtual methodologies to efficiently and …
-
Implementation and Characterization of Cone Beam Computed Tomography Using a Cobalt-60 Gamma Ray Source for Radiation Therapy Patient Localization
Cobalt 60 (Co-60) radiation therapy is a simple and reliable method of treating cancer by irradiating treatment volumes within the patient with high energy gamma rays. Medical linear accelerators (linacs) began to replace Co-60 units during the 1960’s in more developed countries, but Co 60 has …
-
Commissioning of an Upgraded Equinox-100 Cobalt-60 Radiation Therapy Unit in the Varian Eclipse Treatment Planning System
The introduction of Cobalt 60 (Co 60) units in the 1950s established megavoltage radiation therapy worldwide. Unfortunately, advances for the Co 60 radiation treatment units were not heavily pursued over the years and Co 60 units have been steadily replaced by clinical linear accelerators (linacs) …
-
The Role of Cobalt-60 Source in Intensity Modulated Radiation Therapy: From Modeling Finite Sources to Treatment Planning and Conformal Dose Delivery
Cobalt-60 (Co-60) units played an integral role in radiation therapy from the mid-1950s to the 1970s. Although they continue to be used to treat cancer in some parts of the world, their role has been significantly reduced due to the invention of medical linear accelerators. A number of groups have …
-
Advancing an Open-Source Radiation Treatment Planning System for Orthovoltage X-ray and Cobalt-60 Teletherapy
Purpose: A computerized treatment planning system (TPS) plays a crucial role in successful radiation therapy (RT). In recent years the process has evolved from manual planning, where the dose distribution in the target volume was determined using tabulated percent depth dose, to a computerized …
-
Tomographic Imaging on a Cobalt Radiotherapy Machine
… is a global problem, and many people in low-income countries do not have access to the treatment options, such as radiation therapy, that are available in wealthy countries. Where radiation therapy is available, it is often delivered using older Co-60 equipment that has not been updated to …
-
Conformal Radiation Therapy with Cobalt-60 Tomotherapy
… high- precision radiation therapy that utilizes computer-controlled x-ray accelerators to deliver precise radiation doses to malignant tumors. The radiation dose is designed to conform to the three-dimensional (3-D) shape of a tumor by modulating the intensity of the radiation beam to focus a …
-
Coincidence methods for determining scintillation counter efficiency
The efficiency of a 4" x 5" Nal(Tl) scintillation counter for detecting gamma-rays has been measured by a number of experimental techniques, and the results compared with the efficiencies predicted from total absorption cross sections. The experimental techniques involve coincidence measurements of …
-
Gamma-ray energy deposition studies using CaF₂:Mn chip thermoluminescence dosimeters
… chips and the associated readout system using Co-60 and Cs-137 isotopic sources are examined. The resulting procedure for exposure and readout of the CaF<sub>2</sub>:Mn chips is utilized to measure gamma-ray energy deposition distributions in an iron medium. The data from the iron exposures are …
-
Comparing Radiation Shielding Potential of Liquid Propellants to Water for Application in Space
… placing as much material between critical components and the radiation environment as possible. However, with mass and size budgets, it is important to select efficient materials to provide shielding. Currently, NASA and other space agencies plan on using water as a shield against radiation …
-
The Radiation Initiated Polymerization of Styrene
… was studied using gamma radiation from a Co^60 source as the free radical initiator. Conversions up to 50% were obtained and the molecular weight distribution, intrinsic viscosity, bulk viscosity, and osmotic pressure of several samples were measured. A theoretical kinetic model was …
-
Implementação do ensaio cometa para quantificação de dano e reparo do DNA em linfócitos humanos expostos à radiação gama
… ionizante seja amplamente aplicada em áreas como medicina e indústria, seu potencial de induzir danos expressivos ao DNA celular ressalta a importância do monitoramento biológico como estratégia de radioproteção.Dentre as técnicas biodosimétricas disponíveis, o ensaio cometa alcalino …