Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 88 for “"CoCrMo"”.

  1. Nano-scale tribocorrosion of CoCrMo biomedical alloys

    … or pH), the role played by the microstructure of CoCrMo alloys and the contact conditions or the wear mode (sliding, fretting, scratching). However, no work has been undertaken into the interaction of plastic deformation and corrosion mechanisms at the nano-scale. For a better understanding of the …

    soton Download PDF for Nano-scale tribocorrosion of CoCrMo biomedical alloys (opens in a new tab)

  2. The effects of cathodic polarization and simulated infection on the electrochemical properties of CoCrMo and coupled Ti6Al4V+CoCrMo alloy

    … properties of cobalt-chromium-molybdenum (CoCrMo), as well as, titanium-6%aluminum-4%vanadium (Ti6Al4V) coupled with cobalt-chromium-molybdenum. A coupled coupon of Ti6Al4V+CoCrMo was made by using an EPOXY resin to hold the two metals onto the same sample. Normal conditions consisted of …

    buffalo Repository record for The effects of cathodic polarization and simulated infection on the electrochemical properties of CoCrMo and coupled Ti6Al4V+CoCrMo alloy (opens in a new tab)

  3. The corrosion of CoCrMo alloys for biomedical applications

    CoCrMo alloys have been used for biomedical implants for a number of years. They are now frequently used for the metal-on-metal hip resurfacing joints due to their high corrosion and wear performance. The present project was carried out to investigate the feasibility of taking electrochemical …

    birmingham Download PDF for The corrosion of CoCrMo alloys for biomedical applications (opens in a new tab)

  4. CoCrMo alloys in hip and knee replacements application

    CoCrMo alloys have been widely used in hip replacements. On the one hand, they have exhibited excellent long-term survival rates, but recently high failure rates have been observed, associated with adverse local tissue reactions. It is still a puzzle why CoCrMo alloys sometimes work very well, …

    whiterose Download PDF for CoCrMo alloys in hip and knee replacements application (opens in a new tab)

  5. Nitriding of medical grade CoCrMo alloys using HIPIMS discharge

    … a plasma nitriding process for a bio-grade CoCrMo alloy using a High Power Impulse Magnetron Sputtering (HIPIMS) discharge. An industrial-sized PVD machine (Hauzer techno Coating 1000-4, The Netherlands) machine equipped with two HIPIMS and two DC power supplies was utilised for this …

    sheffield-hallam Repository record for Nitriding of medical grade CoCrMo alloys using HIPIMS discharge (opens in a new tab) Download PDF for Nitriding of medical grade CoCrMo alloys using HIPIMS discharge (opens in a new tab)

  6. Synthesis and characterization of Ta-DLC coatings over CoCrMo alloy

    … Ta doped DLC (Ta-DLC) coatings were prepared on CoCrMo alloy and Si (100) wafers using the direct current (DC) magnetron sputtering technique. Ta doping concentration was varied in the DLC matrix by altering the DC power to Ta target from 6 W to 12 W. The structure of the deposited coatings was …

    sask Repository record for Synthesis and characterization of Ta-DLC coatings over CoCrMo alloy (opens in a new tab)

  7. Abrasion-corrosion of cast CoCrMo in simulated hip joint environments

    … and tribo-corrosion performance of a cast CoCrMo (F75) in simulated hip joint environments. The effects of third body particles have been studied in the MoM context using 4 ?m SiC, 1 ?m and 300 nm Al2O3, as well as sub-micron BaSO4. Modified tribo-testers (micro-abrasion, …

    soton Download PDF for Abrasion-corrosion of cast CoCrMo in simulated hip joint environments (opens in a new tab)

  8. Corrosion associated failure mechanisms of CoCrMo alloys in total hip replacements

    … worldwide to restore hip mobility every year. CoCrMo alloys are widely used in hip implants because of their excellent corrosion resistance and mechanical properties. However, some complications related to corrosion of CoCrMo alloys emerged, leading to unexpected clinical failures such as …

    ubc Repository record for Corrosion associated failure mechanisms of CoCrMo alloys in total hip replacements (opens in a new tab) Download PDF for Corrosion associated failure mechanisms of CoCrMo alloys in total hip replacements (opens in a new tab)

  9. Synthesis, characterisation and corrosion studies of CoCrMo nanoparticles for hip implants

    CoCrMo Metal on Metal (MoM) hip implants were designed to be durable, targeting a better quality of life for young, active patients. However, evidence suggests that such implants can release wear particles and metal ions due to a bio-tribocorrosion process. Metallic particles, produced by wear, at …

    whiterose Download PDF for Synthesis, characterisation and corrosion studies of CoCrMo nanoparticles for hip implants (opens in a new tab)

  10. Wear and Corrosion Resistance Improvement of CoCrMo alloy by Tantalum Based Coatings

    … short lifetime of the prosthesis. Medical grade CoCrMo alloy is one of the most common materials used for femoral head fabrication. Unfortunately, the implant fails usually after 15 years of service due to the excessive wear of the polyethylene liner and corrosion of the metallic ball which …

    sask Repository record for Wear and Corrosion Resistance Improvement of CoCrMo alloy by Tantalum Based Coatings (opens in a new tab)

  11. In-situ Electrochemical Surface Engineering in Additively Manufactured CoCrMo for Enhanced Biocompatibility

    … parameters in laser directed energy deposited CoCrMo biomedical alloy. The influence of such a unique microstructural evolution in laser directed energy deposited CoCrMo on electrochemical response in physiological media was elucidated and compared with a conventionally manufactured, …

    unt Repository record for In-situ Electrochemical Surface Engineering in Additively Manufactured CoCrMo for Enhanced Biocompatibility (opens in a new tab)

  12. Small Laser-Textured Dimples for Improved Tribological Performance of CoCrMo in Artificial Hip Joints

    Total hip replacement is a highly successful surgical intervention that restores mobility and improves quality of life for patients with severe joint degeneration. However, the long-term durability of artificial hip joints remains limited by tribological challenges, particularly wear-related …

    arkansas Repository record for Small Laser-Textured Dimples for Improved Tribological Performance of CoCrMo in Artificial Hip Joints (opens in a new tab)

  13. SYNTHESIS AND CHARACTERIZATION OF TANTALUM AND DIAMOND-LIKE CARBON THIN FILMS ON CoCrMo ALLOY SHEETS

    … a biomedical Cobalt-Chromium-Molybdenum alloy (CoCrMo alloy) and investigated to improve the surface functionality of this alloy as femoral heads for artificial hip joints. Ta thin films were deposited on the CoCrMo alloy sheets by magnetron sputtering and the effect of deposition parameters on …

    sask Repository record for SYNTHESIS AND CHARACTERIZATION OF TANTALUM AND DIAMOND-LIKE CARBON THIN FILMS ON CoCrMo ALLOY SHEETS (opens in a new tab)

  14. Effect of powder characteristics and layer thickness on the densification of Selective Laser Melted CoCrMo

    … and layer thickness on selective laser melted CoCrMo parts. The research investigates the effect on final part density by firstly, using two CoCrMo powders with different particle size distributions, secondly, varying layer thickness with constant laser energy densities and lastly, measuring …

    nwu-za Repository record for Effect of powder characteristics and layer thickness on the densification of Selective Laser Melted CoCrMo (opens in a new tab)

  15. Crevice Corrosion Mechanisms of CoCrMo Alloys in Orthopedic Implants: Retrieval Analysis, Nano-tribocorrosion and Cellular Responses

    … implants using cobalt-chromium-molybdenum (CoCrMo) alloys remain clinical concerns and may contribute to implant failure. The underlying corrosion mechanisms are not yet fully understood, leaving a critical research gap. We hypothesized that corrosion in modular junctions may be driven by …

    clemson Repository record for Crevice Corrosion Mechanisms of CoCrMo Alloys in Orthopedic Implants: Retrieval Analysis, Nano-tribocorrosion and Cellular Responses (opens in a new tab)

  16. Improvement of Diamond-Like Carbon Adhesion on CoCrMo by Microdiamond and Nitrogen Incorporation for Wear Resistant Applications

    … the service lifetime of hip joints made of CoCrMo alloy. DLC thin films have been attracted the most interest because of its extreme smoothness, low coefficient of friction, high hardness and excellent biocompatibility. One of the key issues that limit the use of DLC is its poor adhesion to …

    sask Repository record for Improvement of Diamond-Like Carbon Adhesion on CoCrMo by Microdiamond and Nitrogen Incorporation for Wear Resistant Applications (opens in a new tab)

  17. Cellular Corrosion of CoCrMo Total Knee Implants: Understanding Underlying Mechanisms Through Retrieval Analysis and Simulated Inflammatory Conditions

    … board approval, 41 Cobalt-Chromium-Molybdenum (CoCrMo) cadaveric primary total knee arthroplasty specimens were collected. After removal and cleaning, light microscopy was utilized to identify areas of ICIC-like damage scares. CoCrMo, zirconium nitride (ZrN)coated, and Oxinium knee implants were …

    tenn-hsc Repository record for Cellular Corrosion of CoCrMo Total Knee Implants: Understanding Underlying Mechanisms Through Retrieval Analysis and Simulated Inflammatory Conditions (opens in a new tab)

  18. Effect of hot isostatic pressing on the corrosion behaviour of additive manufactured CoCrMo in simulated human body fluid

    … alloys such as cobalt–chromium–molybdenum (CoCrMo). Some of the challenges of using AM include parts that are susceptible to porosity, material anisotropy and high residual stresses, which degrade the mechanical properties of the components. However, these issues can be resolved through hot …

    manitoba Repository record for Effect of hot isostatic pressing on the corrosion behaviour of additive manufactured CoCrMo in simulated human body fluid (opens in a new tab)

  19. Analysis and Modulation of In Vitro Cell Response to Metal Ions From CoCrMo Alloys Used in Orthopaedic Applications

    … the effects of Co2+ and Cr3+ released from CoCrMo alloys used in hip implants on macrophage chemokine release; 2.) To determine if Co2+, Cr3+, and the chemokines in cultures of macrophages exposed to Co2+ and Cr3+ can induce migration of T and B lymphocytes; and 3) To analyze the potential …

    ottawa-retro Repository record for Analysis and Modulation of In Vitro Cell Response to Metal Ions From CoCrMo Alloys Used in Orthopaedic Applications (opens in a new tab)

Page 1 of 5