Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 20 for “"Coded Excitation"”
-
Improving ultrasonic imaging using novel coded excitation techniques
… on the source bandwidth. Recently, a novel coded excitation and pulse compression technique, known as Resolution Enhancement Compression (REC), was developed. REC enhances the -6 dB bandwidth of an ultrasonic imaging system. In this dissertation, the limitations of the REC technique were …
-
Efficient coded excitation beamforming system for medical ultrasound imaging
… electronic circuits onto a single chip. With coded excitation techniques, the necessary drive voltage can be reduced if the duration of the drive signal (coded signal in this case) is increased. Pulse compression techniques are used to compress the returned signal to achieve the high …
-
Deep structure ultrasound imaging using fundamental and third harmonic coded excitation techniques
A novel coded excitation method, combining Golay coding with fundamental and third harmonic 1, 3 chirps with resolution enhancement compression (REC) and frequency compounding, increases the axial resolution, lateral resolution, penetration depth and the contrast-to-noise ratio (CNR) for an …
-
2D and 3D Ultrafast Ultrasound Imaging With Coded Excitation and Aperiodic Apertures
… speed by introducing novel aperiodic temporal excitations and aperiodic apertures that can be used to image fast dynamic processes with enhanced image quality in 3D at hundreds of frames per second. While scanline imaging can be made faster by simply imaging multiple lines of sight in parallel, …
-
Sidelobe Degradation of Complementary Golay Coded Excitation by Nonlinear Effects in Ultrasonic Imaging
… however the interaction of complementary Golay coded excitations with harmonic distortion introduced by nonlinear phenomena, such as propagation through large areas of fluid or fat in the body, has not been fully investigated.<br/><br/>This work is the first use simulated and experimental work …
-
Small lesion detection with resolution enhancement compression: a method of coded excitation/pulse compression
A novel coded excitation method, resolution enhancement compression (REC), increases the axial resolution and the echo signal-to-noise ratio (eSNR) for an ultrasonic imaging system. The REC technique was examined for its ability to improve lesion detectability. In addition to lesion detectability, …
-
Coded excitation with lead-free ultrasonic arrays : from complex structural integrity assessments to intravascular ultrasound imaging
… MHz) ultrasonic arrays in these two settings. Coded excitation strategies in conjunction with Full Matrix Capture (FMC) and Total Focusing Method (TFM) were applied to inspect thick non-planar industrial components. The Golay-based TFM demonstrated superior performance compared to the …
-
Potential for coded excitation to improve the detection of tissue and blood motion in medical ultrasound.
… accurate velocity or displacement estimation. Coded excitation has recently received a growing interest in the medical ultrasound community. The use of these techniques, originally developed in the radar field, makes it possible to increase the depth of penetration in B-mode imaging, while …
-
Applying synthetic aperture, coded excitation, and tissue harmonic imaging techniques to allow ultrasound imaging with a virtual source
… of focus. The second technique examined was coded excitation, a means of improving SNR while maintaining the axial resolution. The third technique was tissue harmonic imaging, which produces a narrower beamwidth and reduced sidelobes, and therefore can improve spatial resolution and contrast …
-
Ultrasound imaging using coded signals
Modulated (or coded) excitation signals can potentially improve the quality and increase the frame rate in medical ultrasound scanners. The aim of this dissertation is to investigate systematically the applicability of modulated signals in medical ultrasound imaging and to suggest appropriate …
-
Use of chirps in medical ultrasound imaging
… attenuation in tissue, which increases with the excitation frequency. The chirp coded excitation however can increase the total transmitted energy using longer pulse durations, while the resolution can be recovered by decoding on receive. Therefore, chirp signals offer potential advantages over …
-
Mathematical Modeling of the Vaporization of Encapsulated Perfluorocarbon Nanodroplets using Chirp Ultrasound
… a larger degree of attenuation within tissues. Coded excitation schemes where the outgoing ultrasound waveform is either frequency-modulated or phase-modulated can be utilized to increase axial resolution without sacrificing transmitted power and penetrative depth. One example of a coded …
-
An Exploration of Methods to increase the speed of Array-based Ultrasound Imaging
… being circular but more<br/>plane-wave like.<br/>Coded Excitation signals have a wide range of use, and have been implemented for ultrasonics<br/>as a means of increasing signal-to-noise ratio (SNR). Following on from the above investigation,<br/>this thesis uses these signals in the form of …
-
Post-beamforming filtering for enhanced contrast resolution in medical ultrasound.
… reverberations. We have investigated the use of coded excitation, together with a 1D post-beamforming pseudoinverse filter, in improving the SNR and reducing reverberation leading to enhanced contrast resolution, especially for deeper target. Experimental demonstration of the algorithm was …
-
Considerations for an in-process ultrasonic phased array inspection method for narrow gap welds
… a data compression technique utilising coded excitation has been developed and demonstrated, allowing single-bit digitisation of ultrasonic data. This has been shown to provide comparable results to standard resolution digitisation when implemented with TFM and Phase Coherence Imaging …
-
Clinical transitions in photoacoustic imaging
… imaging techniques including s-sequence excitation and minimum variance beamforming. The final focus is on clinical applications. We show photoacoustic imaging of gene expression through a tyrosinase reporter gene developed by my colleagues with exciting applications in studying metabolic …
-
Autonomous unmanned aerial vehicle for non-destructive testing
… improved inspection accuracy while applying a coded excitation to the ultrasonic measurement system to increase Signal-to-Noise Ratio. The maximum error was reduced from 0.83 mmto 0.66 mm in scenarios where the transducer was sub-optimally aligned.
-
Real-time imaging of thermal and mechanical tissue response to focused ultrasound.
… shift. Synchronous silencing of ARF beam and coded excitation technique were used to allow the capture of the full dynamics of tissue deformation in response to the ARF pulse. A modulation unit was also designed to control the temporal behavior of the ARF beam to allow for the investigation of …
-
A Study of Wave Propagation and Limited-Diffraction Beams for Medical Imaging
In this dissertation, wave propagation and limited-diffraction beams are further studied to gain a deep understanding of their principles and applications in ultrasonic imaging. With the concept of angular spectrum, the ultrasound fields generated by array transducers are mapped as the summation of …
-
Exploring the effects of coded excitations and pulse compression on the performance of magneto-acousto-electrical tomography with magnetic field measurements in mr magnet
This thesis investigates the effects of coded excitations and pulse compression techniques on the performance of Magneto-Acousto-Electrical Tomography (MAET) with magnetic field measurements in MR magnet. MAET maps conductivity distributions in biological tissues by utilizing the interaction of …