Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 27 for “"Coded aperture imaging"”.
-
Possibilities and limitations of coded aperture imaging
We have simulated the performance of various apertures used in Coded Aperture Imaging - optically. Coded pictures of extended and continuous-tone planar objects from the Annulus, Twin Annulus, Fresnel Zone Plate and the Uniformly Redundant Array have been decoded using a noncoherent correlation …
-
Coded Aperture Imaging: Digital Decoding and Tomographic Artifacts
Made available in DSpace on 2014-12-12T20:54:34Z (GMT). No. of bitstreams: 1 7709189.pdf: 4576715 bytes, checksum: a01295fbefe6961b97ab6b87b5d1330d (MD5) Previous issue date: 1976
-
Quantification of Fast-Neutron Sources with Coded Aperture Imaging
… or within the measurement device. In prior work, coded-aperture fast neutron imaging has been developed to demonstrate the imaging of neutron emitting radiation sources in a qualitative fashion, where the sources may be located meters to tens of meters away. Building upon prior work, this work …
-
A Compact Neutron Scatter Camera Using Optical Coded-Aperture Imaging
… (meter scale) and not portable. Using optical coded-aperture imaging, fast plastic scintillator, and fast photodetectors that were sensitive to single photons, a portable neutron scatter camera was designed and simulated. The design was optimized, an experimental prototype was constructed, and …
-
Coded aperture imaging application in one-sided imaging of visually obscured objects
… and reveal their contents. However, traditional imaging techniques require a two-sided apparatus with a radiation source and a detector on opposite sides of the concealed object. One-sided imaging of concealed objects is made possible by a technique called backscatter imaging, utilizing high …
-
Coded Aperture Imaging: novel approaches to high-energy high-resolution laboratory imaging
… need to be complimented with development of imaging capabilities, in order to fully characterise and utilise the new source potential. Here, coded apertures are used to investigate novel approaches to high-energy high-resolution aperture based imaging. Firstly, coded aperture theory is …
-
Coded aperture imaging with a HURA coded aperture and a discrete pixel detector
An investigation into the gamma ray imaging properties of a hexagonal uniformly redundant array (HURA) coded aperture and a detector consisting of discrete pixels constituted the major research effort associated with this thesis. Such a system offers distinct advantages for the development of …
-
Shape Dynamical Models for Activity Recognition and Coded Aperture Imaging for Light-Field Capture
… this dissertaion, we investigate computational imaging, an emerging field where the process of image formation involves the use of a computer. The current trend in computational imaging is to capture as much information about the scene as possible during capture time so that appropriate images …
-
SIMULATED ANNEALING AND ESTIMATION THEORY IN CODED-APERTURE IMAGING (RECONSTRUCTION, MONTE CARLO, WIENER FILTER).
Coded-aperture imaging without detector motion can be used to reconstruct three-dimensional radionuclide distributions in the context of nuclear medicine. This approach offers several advantages over the rotating gamma-ray camera systems presently employed in the clinic. These advantages include …
-
MOBILE, HYBRID COMPTON/CODED APERTURE IMAGING FOR DETECTION, IDENTIFICATION AND LOCALIZATION OF GAMMA-RAY SOURCES AT STAND-OFF DISTANCES
… truck-based, hybrid gamma-ray spectroscopic and imaging system able to quickly detect, identify and localize, radiation sources at standoff distances through improved sensitivity provided by multiple detection modes while minimizing the false alarm rate. Reconstruction of gamma-ray sources is …
-
USE OF A PRIORI INFORMATION FOR IMPROVED TOMOGRAPHIC IMAGING IN CODED-APERTURE SYSTEMS
Coded-aperture imaging offers a method of classical tomographic imaging by encoding the distance of a point from the detector by the lateral scale of the point response function. An estimate, termed a layergram, of the transverse sections of the object can be obtained by performing a simple …
-
FlatCam: Lensless Imaging, Principles, Applications and Fabrication
… is a thin form-factor camera that consists of a coded mask placed on top of a bare, conventional sensor array. The design is inspired by coded aperture imaging principles; each sensor pixel records a linear combination of the scene in front of the camera, and a computational algorithm …
-
Machine Learning and Neutron Sensing in Mobile Nuclear Threat Detection
… at standoff distance using neutron and gamma ray coded aperture imaging. A major research goal of the project was to understand the benefit of neutron sensing in the mobile threat search scenario. To this end, a series of mobile measurements were conducted with the completed DDLI PoC. These …
-
Event Localization In Bulk Scintillator Crystals Using Optical Coded Apertures
… phototransducer. This method uses principles of coded-aperture imaging to localize an event to approximately a 1-cubic-mllimeter voxel in three dimensions inside a large crystal. This work explores all aspects of the concept including current state of the art event localization capabilities, …
-
Hard X-ray Super-Survey: Combining Swift/BAT and INTEGRAL/IBIS
… by the large systematic errors intrinsic to coded aperture imaging. Treating this as a pilot to lay the groundwork for future expansion, we also implemented new wavelet filtering techniques to reduce the large-scale structure which has shown to increase the number of detections. A source …
-
Gamma ray imaging in industrial and medical applications
… and development of solutions for gamma-ray imaging problems in Nuclear Medicine and nuclear decommissioning. The designs presented are: a compact gamma camera for locating the sentinel lymph node, a near-field coded aperture imager for <i>in-vivo</i> imaging of the distribution of a …
-
A position-sensitive detector for hard X-ray astronomy
… required performance of the next generation of imaging telescopes are reached. Imaging in this waveband is made difficult by; the penetrating nature of the X- ray photons, which makes the use of conventional optics impossible. The techniques applicable to hard X-ray imaging are reviewed, with …
-
GAMMA-RAY IMAGING OBSERVATIONS OF THE CRAB AND CYGNUS REGIONS
… keV to 9.3 MeV. It utilizes a technique known as coded aperture imaging in order to obtain spatially resolved images of the sky with an angular resolution of $3.8\sp\circ.$ This detector is the first flight-ready instrument of this type operating at energies above 160 keV. The first successful …
Page 1 of 2