Oxide materials as efficient, radiation tolerant and fast scintillators /
… require scintillation detectors with exemplary time resolution that cannot be reached using conventional scintillating crystals. The main goal of this work is revealing processes of excitation transfer in scintillating materials, which are important for developing efficient, radiation tolerant …
-
Production of a well collimated neutron beam using the associated particle technique
… pulse height analysis was used to reduce the coincidence time resolution between the detected neutrons and the associated He³ recoil particle to 4.6 nanoseconds by taking into account the variations in flight times of the He³ particles. A rotating thin film deuterated polyethylene target was …
-
Towards a next-generation preclinical PET/MR insert with improved timing and count rate performance
… circuit. Some limitations include a 2.5ns coincidence time resolution (CTR), a relatively long signal duration of >1.5us, and a 1.3us paralyzable dead time. This thesis focuses on characterizing these limitations and demonstrating a second-generation detector module for improved timing and …
-
INVESTIGATION OF CADMIUM ZINC TELLURIDE DETECTOR FOR MEDICAL IMAGING APPLICATIONS
… number of properties, including superior energy resolution, 3D photon position sensitivity, compact size, direct photon conversion and energy-resolving capability, make CZT a promising candidate for positron emission tomography (PET) and photon-counting X-ray imaging systems. Despite these …
-
Development of a Scintillator Cluster Detector and Microcontroller Integrated Detector Circuit
… were mounted to 2x2 SiPM arrays. The energy and time resolution, energy calibration and linearity of the detector were measured for each detector element as well as add-back being used for each detector pairing. The long-term performance of the hermetic seal was tested over a two-month period and …
-
Development of Novel Scintillation Detection Techniques for Use in Nuclear Physics and Medical Applications
… area studied regarding their characteristics and coincidence time measurement. According to the measurement result, the dependencies of bias voltage, temperature, gain and dark current were consistent with the literature. Coincidence time resolution was gradually improved from 512 ps to 276 ps for …
-
Solid-state single-photon Detectors and CMOS Readaout Circuits for Positron Emission Tomography Applications
… dark count noise, 0.85% afterpulsing for a dead time of 150ns at 3V excess bias. The photon detection probability is about 31% at 450nm wavelength at 5V excess bias. The SPAD exhibits a timing jitter of 82ps (FWHM) under a blue laser, which is potentially suitable for D-SiPMs in PET application. …
-
Timing performance of FBK Silicon Photomultipliers for biomedical applications: ultimate time resolution and analysis of the avalanche build-up
L'abstract è presente nell'allegato / the abstract is in the attachment
-
Characterisation of Silicon Photomultipliers for the detection of Near Ultraviolet and Visible light
… devices are: medical application (e.g. the Time of Flight PET, ToF-PET, scanners), the rare events Physics experiments (e.g. NEXT and DarkSide) and Astroparticle Physiscs experiments (e.g. the Cherenkov Telescope Array Observatory, CTA). The ToF-PET scanners are promising medical techniques …