Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 31 for “"Collision cross section (CCS)"”.

  1. Development of Modular High-Resolution Ion Mobility Orbitrap Platforms for Native Mass Spectrometry

    … can be inferred by the rotationally-averaged collision cross-section (CCS) measurements. Native IM-MS is complementary to nuclear magnetic resonance (NMR) spectroscopy, X-Ray crystallography (XRD), cryogenic-electron microscopy (CryoEM), as well as surface plasmon resonance (SPR) and …

    tamu Repository record for Development of Modular High-Resolution Ion Mobility Orbitrap Platforms for Native Mass Spectrometry (opens in a new tab)

  2. DEVELOPMENT OF A COMPUTATIONAL COLLISION CROSS SECTION DATABASE FOR SINGLY AND DOUBLY CHARGED POLYALANINE CATIONS

    … of a universally applicable and comprehensive Collision Cross Section (CCS) database. This necessity is driven by the goal to eliminate experimental discrepancies due to lab-specific or instrument-specific conditions, and to strengthen the robustness of experimental outcomes. Using the POMICS …

    msu Repository record for DEVELOPMENT OF A COMPUTATIONAL COLLISION CROSS SECTION DATABASE FOR SINGLY AND DOUBLY CHARGED POLYALANINE CATIONS (opens in a new tab)

  3. Utility of Ion Mobility – Mass Spectrometry in Peptidoglycan Structural Determination

    … Potential isomers, modifications, and cross-linking patterns within whole cell digests lead to complex samples that typically require manual analysis. The introduction of a method for streamlining the identification of peptidoglycan components (muropeptides) is needed to develop a …

    vt Repository record for Utility of Ion Mobility – Mass Spectrometry in Peptidoglycan Structural Determination (opens in a new tab)

  4. Ion Mobility and Gas-Phase Covalent Labeling Study of the Structure and Reactivity of Gaseous Ubiquitin Ions Electrosprayed from Aqueous and Denaturing Solutions

    … with selective covalent structural probes. Collision cross-section (CCS) distributions were measured prior to ion/ion reactions to ensure the ubiquitin ions were not unfolded when they were introduced to the gas phase. Ubiquitin ions were electrosprayed from aqueous and methanolic solutions …

    iupui Repository record for Ion Mobility and Gas-Phase Covalent Labeling Study of the Structure and Reactivity of Gaseous Ubiquitin Ions Electrosprayed from Aqueous and Denaturing Solutions (opens in a new tab)

  5. Rapid Exposure Assessment of Complex Environmental Samples in Disaster Research Using Traditional and Novel Methods

    … based on unique mass-to-charge (m/z) and collision cross section (CCS). This proposal’s objective is to compare and develop methods for rapid exposure assessment of complex environmental samples in disaster research with the use of traditional and novel methods. Foremost, we will perform a …

    tamu Repository record for Rapid Exposure Assessment of Complex Environmental Samples in Disaster Research Using Traditional and Novel Methods (opens in a new tab)

  6. Development of mass spectrometry strategies for intact protein applications

    … shape in the gas phase. This parameter (known as collision cross section, CCS) can be measured in an Orbitrap by monitoring the rate at which an ion signal decays at very low pressures (and very few collisions). This decrease in signal correlates with the CCS of an ion as larger ions are more …

    texas Repository record for Development of mass spectrometry strategies for intact protein applications (opens in a new tab)

  7. Determining Molecular Physicochemical Properties Using Differential Mobility Spectrometry

    … predict physicochemical properties such as the collision cross section (CCS) and single solvent binding energies (BEs) using experimental DMS data. Chapter 3 shows the ability of DMS to separate derivatized amphetamines and methamphetamine isomers and uses calculated BEs to identify the …

    waterloo Repository record for Determining Molecular Physicochemical Properties Using Differential Mobility Spectrometry (opens in a new tab)

  8. Protein complexes in the gas phase: structural insights from ion mobility-mass spectrometry and computational modelling

    … (IM-MS) is explored. An assessment of collision cross section (CCS) measurement accuracy using travelling-wave IM (TWIMS) instrumentation was carried out (Chapter 3). Through the collation of a protein complex CCS database and the development of a calibration framework for TWIMS, …

    oxford Repository record for Protein complexes in the gas phase: structural insights from ion mobility-mass spectrometry and computational modelling (opens in a new tab)

  9. High-Resolution Ion Mobility Analysis of Isomeric Bile Acids Using Structures for Lossless Ion Manipulations (SLIM) IM-MS

    … and shape of the molecules by calculating the collision cross-section (CCS). In this study, we aim to analyze different bile acids using Structures for Lossless Ion Manipulations (SLIM) ion mobility and comparing nitrogen and helium buffer gas to determine the best method of separation. The …

    clemson Repository record for High-Resolution Ion Mobility Analysis of Isomeric Bile Acids Using Structures for Lossless Ion Manipulations (SLIM) IM-MS (opens in a new tab)

  10. Complex Mixture Analysis Using Ion Mobility Spectrometry-Mass Spectrometry (IMS-MS) and Computational Techniques

    … deuterium scrambling (HD scrambling), and collision-induced dissociation (CID) were coupled with IMS-MS measurements to assist in the characterization of metabolites, lipids, and peptides. Unique mass spectral patterns were obtained for different classes of biological molecules upon HDX. …

    wvu Repository record for Complex Mixture Analysis Using Ion Mobility Spectrometry-Mass Spectrometry (IMS-MS) and Computational Techniques (opens in a new tab)

  11. Optimization of Lennard-Jones potential parameters and benchmark comparison between ion mobility calculators in free molecular regime

    … few decades for calculating Ion Mobility and Collision Cross Section (CCS), still there is a need to develop it in terms of its efficiency and performance, to better understand the dynamics of the collision. The work presented here demonstrates the efficiency and performance of newly developed …

    iupui Repository record for Optimization of Lennard-Jones potential parameters and benchmark comparison between ion mobility calculators in free molecular regime (opens in a new tab)

  12. Ion Mobility Spectrometry Coupled to Mass Spectrometry for Glycoanalysis: Ion-Neutral Collision Cross Section Calibration and Application to Glycopeptides

    … arrival time distributions (ATDs) and subsequent collision cross section (CCS) measurements, which become analytically useful when comparing data to other laboratories. IMSMS has shown significant potential in the field of glycoanalysis. Specifically, traveling wave ion mobility spectrometry …

    nebraska Repository record for Ion Mobility Spectrometry Coupled to Mass Spectrometry for Glycoanalysis: Ion-Neutral Collision Cross Section Calibration and Application to Glycopeptides (opens in a new tab)

  13. Determination of Xenobiotic and Endogenous Metabolites Using Ion Mobility-Mass Spectrometry and Machine Learning

    … unknown metabolites through the measurement of collision cross section (CCS). The diversity of small molecule chemical space necessitates the ability to predict CCS with high accuracy, rather than relying solely upon experimental CCS databases for annotation of unknowns. This dissertation aims …

    washington Repository record for Determination of Xenobiotic and Endogenous Metabolites Using Ion Mobility-Mass Spectrometry and Machine Learning (opens in a new tab)

  14. Fueling advances in ultra performance liquid chromatography – and ion mobility – mass spectrometry as platforms for x-omic analyses.

    … Analyte assignments were supported via IM-MS collision-cross-section (CCS) measurements and trendline analysis. An automated "omics" approach utilizing UPLC-HR-TOF-MS was developed for the identification of previously unknown lignocellulosic degradation products. The approach combines …

    baylor Repository record for Fueling advances in ultra performance liquid chromatography – and ion mobility – mass spectrometry as platforms for x-omic analyses. (opens in a new tab)

  15. Structural analysis of biomolecules using ion mobility and mass spectrometry : exploration of ion rearrangements and conformations.

    … modeling data are presented to demonstrate that collision-induced dissociation (CID) of 5′ phosphorylated DNA can generate rearranged [phosphopurine]- product ions. Limited IM resolving powers may hinder adequate characterization of conformationally similar ions and reduce the accuracy of …

    baylor Repository record for Structural analysis of biomolecules using ion mobility and mass spectrometry : exploration of ion rearrangements and conformations. (opens in a new tab)

  16. Advancements in the characterization of intact proteins by ultraviolet photodissociation and charge detection mass spectrometry

    … for the simultaneous measurement of mass and collision cross section (CCS) for large native-like protein complexes, enabling insights into their topology and size. CDMS excels in the analysis of heterogeneous analytes, where overlapping charge states are not resolved by conventional mass …

    texas Repository record for Advancements in the characterization of intact proteins by ultraviolet photodissociation and charge detection mass spectrometry (opens in a new tab)

  17. Implementation of Liquid Chromatography, Ion Mobility Spectrometry, and Mass Spectrometry for the Analysis of Steroids and Lipids

    … major themes: (1) Increasing the accuracy of IMS collision cross section (CCS) calibration, (2) Enhancing separation of steroid and steroid conjugates through IMS using metal adduction, and (3) Applying these techniques to biological mixtures. The first four chapters focus on increasing the …

    nebraska Repository record for Implementation of Liquid Chromatography, Ion Mobility Spectrometry, and Mass Spectrometry for the Analysis of Steroids and Lipids (opens in a new tab)

  18. Development and Application of an Electrospray Ionization Ion Mobility-mass Spectrometer Using an RF Ion Funnel and Periodic-focusing Ion Guide

    … (R > 56) to separate ions having a small collision cross section (CCS) difference at low-to-intermediate field strength (10 V cm-1 torr-1~19 V cm-1 torr-1), and observation of multiple conformers from isobaric ions at various operation conditions. Gate and transfer ion optic design needed …

    tamu Repository record for Development and Application of an Electrospray Ionization Ion Mobility-mass Spectrometer Using an RF Ion Funnel and Periodic-focusing Ion Guide (opens in a new tab)

  19. Putting the Pieces Together Again: Characterizing Trisaccharides by the Energetics of Their Primary Fragmentation Pathways and Their Ion Mobility

    … the study of the fragment ions formed during collision induced dissociation (CID), the fragments formed depend on the structure and stability of the precursor molecule and can be used to identify the compounds. These fragmentation pathways will be as complex as the species that form them. To …

    ottawa-retro Repository record for Putting the Pieces Together Again: Characterizing Trisaccharides by the Energetics of Their Primary Fragmentation Pathways and Their Ion Mobility (opens in a new tab)

Page 1 of 2