Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 9 of 9 for “"Column axial load"”.
-
Effect of Column Axial Load on Skewed SMF RBS Connection Demands
… limit the use of non-orthogonal (skewed) beam-column connection geometries. A recent study has investigated laterally skewed moment frame connections, indicating that skew increases the potential for column twist and column flange yielding; however, it is unclear how realistic column axial …
-
Reinforced concrete beam-column joints strengthened in shear with embedded bars
Beam-column (BC) joints play an important role in the seismic performance of moment-resisting reinforced concrete (RC) frame structures. Without adequate joint shear reinforcement, BC joints can be the most vulnerable elements during an earthquake. Several techniques for improving the seismic …
-
Seismic behaviour of deficient exterior RC beam-column joints.
… stiffness and strength deterioration of beam-column joints can have a detrimental effect on the integrity and vulnerability of reinforced concrete frame structures, especially in older buildings in developing countries. As a result, there is a need to develop efficient structural evaluation …
-
Seismic Behaviour of Exterior Beam-Column Joints Reinforced with FRP Bars and Stirrups
Reinforced concrete beam-column joints (BCJs) are commonly used in structures such as parking garages, multi-storey industrial buildings and road overpasses, which might be exposed to extreme weathering conditions and the application of de-icing salts. The use of the non-corrodible fiber-reinforced …
-
Seismic performance of circular columns rehabilitated with sprayed-GFRP composites
… the seismic behaviour of RC circular columns rehabilitated using sprayed-glass fibre reinforced polymer (sprayed-GFRP) composites. Six large-scale RC circular columns were constructed and tested under reversal-cyclic load and constant axial load (equal to 20% of column axial load …
-
On the Seismic Performance of Skewed Special Moment Frame Reduced Beam Section Connections
… orthogonal connections between the beam and column. This dissertation investigates the effect of adding skew within SMF RBS connections and provides insights into allowable skew levels for design, widening the application of SMF RBS connections. The study presented herein involves parametric …
-
EXPERIMENTAL AND NUMERICAL FAILURE ANALYSIS OF DEEP STEEL COLUMN SECTIONS
… limit state of collapse is approached. Exterior columns in perimeter steel moment-resisting frame structures that are exposed to strong earthquakes experience bending moment demands with high levels of axial load due to overturning. Deep wide flange sections can be used as exterior columns to …
-
Seismic performance of GFRP-RC beam-column and beam-column-slab subassemblies
… of individual FRP-RC elements such as beams, columns and slabs under monotonic loading, studies on the integral behaviour of FRP-RC subassemblies where two or more structural elements interact with each other are scarce. The lack of research data is especially evident concerning one of the …
-
Response of Wide Flange Steel Columns Subjected to Constant Axial Load and Lateral Blast Load
The response of wide flange steel columns subjected to constant axial loads and lateral blast loads was examined. The finite element program ABAQUS was used to model W8x40 sections with different slendernesses and boundary conditions. For the response calculations, a constant axial force was first …