  1. The effects of carrier gas viscosity on column efficiency in capillary gas chromatography

    … carrier gas viscosity of hydrogen and helium on column efficiency; particularly when employing thin films. When using thin films, mass transfer in the stationary phase becomes negligible and mass transfer in the mobile phase predominates. It was envisioned that when employing thin films hydrogen …

    vt Repository record for The effects of carrier gas viscosity on column efficiency in capillary gas chromatography (opens in a new tab)

  2. The determination of HETP and column efficiency for an annular preparative-scale gas-liquid chromatographic column

    … to design, build, and test a preparative-scale column which contained a blocked-off center tube, thus forming an annular space for the packing. The chromatographic system for this study consisted of 1-methylnaphthalene injections with helium carrier gas and a liquid phase of Craig polyester …

    vt Repository record for The determination of HETP and column efficiency for an annular preparative-scale gas-liquid chromatographic column (opens in a new tab)

  3. Optimization of the column efficiency and production rate for displacement chromatography : an application of the shock layer theory

    <p>Although there has been constant efforts to solve the contradicted experimental reports about the optimum linear velocity for the minimum overlap in the mixed zone of the isotactic train in displacement chromatography, all the attempts are not successful since they are based on the not realistic …

    utk-theses Repository record for Optimization of the column efficiency and production rate for displacement chromatography : an application of the shock layer theory (opens in a new tab)

  4. Mass Transfer Studies In A 'Finpak' Distillation Column

    … as to not only provide a measure of 'Finpak' column efficiency under a variety of such conditions, but also to illustrate the effect such variables have on the overall distillation efficiency.<br/><br/>The results of the research indicate that the 'Finpak' fractionating column is a suitable …

    southwales Repository record for Mass Transfer Studies In A 'Finpak' Distillation Column (opens in a new tab) Download PDF for Mass Transfer Studies In A 'Finpak' Distillation Column (opens in a new tab)

  5. Microchip Thermal Gradient Gas Chromatography

    … power consumption have been achieved, losses in column efficiency and resolution, complex construction processes and difficulties experienced in recovering damaged columns have also become problematic for routine use of resistively heated columns. To solve these problems, a new resistively heated …

    byu Repository record for Microchip Thermal Gradient Gas Chromatography (opens in a new tab) Download PDF for Microchip Thermal Gradient Gas Chromatography (opens in a new tab)

  6. Retention trends of chemical classes using CCl₄ as a carrier solvent in normal-phase HPLC

    … (NH₂), cyano (CN) and polar amino-cyano (PAC)) columns were investigated with CCl₄ and refractive index (RI) detection. The sample capacity and column efficiency of each of the NH₂ and PAC columns were measured and compared. Besides, a method of determining unmeasurable capacity factors (k' …

    vt Repository record for Retention trends of chemical classes using CCl₄ as a carrier solvent in normal-phase HPLC (opens in a new tab)

  7. Computer analysis of asymmetric peaks in gas chromatography

    … samples were chromatographed on squalane for columns of 3, 6 and 12 foot lengths and 1/8", 1/ 4" and 1/2" diameters as a function of sample size. Peak symmetry was monitored by measuring skew, γ₁ , and "excess," γ₂ two quantities derived from the higher central moments. Skew was found to …

    vt Repository record for Computer analysis of asymmetric peaks in gas chromatography (opens in a new tab)

  8. On-line multidimensional HPLC: development, theory and applications

    … one coupling two liquid chromatographic columns (LC/LC), and one coupling liquid and gas chromatography (LC/GC). Theoretical equations relating the reproducibility, accuracy and transfer efficiency to system operating variables such as flow rate, retention time, column efficiency and …

    vt Repository record for On-line multidimensional HPLC: development, theory and applications (opens in a new tab)

  9. Radial Heterogeneity and Surface Properties of Columns Used in High Performance Liquid Chromatography

    <p>The radial heterogeneity of some columns used in high performance liquid chromatography (HPLC) was investigated using an on-column microelectrochemical amperometric detector. Such a detector allowed the recording of the elution profiles at different spatial positions throughout the column exit …

    utk-theses Repository record for Radial Heterogeneity and Surface Properties of Columns Used in High Performance Liquid Chromatography (opens in a new tab)

  10. Monolithic and perfusive packings: A study of surface chemistry and mass transfer in protein separation

    … size distribution which contributes to higher column throughput and higher column efficiencies compared to conventional particulate stationary phases. In this research, a systematic comparative study on these two types of column media was performed to elucidate the similarities and differences …

    nus Repository record for Monolithic and perfusive packings: A study of surface chemistry and mass transfer in protein separation (opens in a new tab) Download file for Monolithic and perfusive packings: A study of surface chemistry and mass transfer in protein separation (opens in a new tab)

  11. Preparative high performance liquid chromatography

    … was developed and used to pack sixteen HPLC columns having different lengths and internal diameters with 10 µm Lichrosorb Sl-100. The evaluation of these columns led to several conclusions: the column efficiency, expressed in plates per meter, is a function of the ratio of column internal …

    vt Repository record for Preparative high performance liquid chromatography (opens in a new tab)

  12. The Development And Study Of Chelating Substrates For The Separation Of Metal Ions In Complex Sample Matrices

    … the separation of trace metals using a single column under both isocratic and gradient elutions were investigated. Neutral polystyrene based resins from a variety of manufacturers including a hypercrosslinked resin (MN 200) were functionalised via impregnation with chelating dyestuffs or …

    plymouth Repository record for The Development And Study Of Chelating Substrates For The Separation Of Metal Ions In Complex Sample Matrices (opens in a new tab)

  13. A fundamental study of simulated moving bed chromatography under linear condition

    … satisfies the same safety margin; (3) the column efficiencies are moderate.</p> <p>The performance of SMB depends not only on the chromatographic behavior of the two components but also on the configuration of SMB and the switching of the ports. Two different configurations were studied in …

    utk-theses Repository record for A fundamental study of simulated moving bed chromatography under linear condition (opens in a new tab)

  14. A two-case study of band broadening in liquid chromatography

    … axial dispersion.</p> <p>In the second study, column efficiency and plate height were calculated for polystyrene (MW: 1.87 x 10<sup>6</sup>) on a silica column at several flow rates between 1.0 and 100 ml/min. Reduced linear velocities up to 1,000,000 were achieved. The classical Van Deemter …

    ut-knoxville Repository record for A two-case study of band broadening in liquid chromatography (opens in a new tab)

  15. In-column polymer modifications: Advancing polymer bonded phases

    … disease biomarkers and quality control. The efficiency of glycoprotein separations is limited by the bonded phases, requiring advances in chromatographic materials. Such advances would improve resolution, allowing for more species to be isolated from a mixture and studied. Our group found …

    purdue-thes Repository record for In-column polymer modifications: Advancing polymer bonded phases (opens in a new tab)

  16. Application of soil mechanics and the finite element method (FEM) to High Performance Liquid Chromatography (HPLC) columns

    <p>The efficiency of High Performance Liquid Chromatography columns is often reduced due to radial variations of the density or void ratio of the silica packing material. This heterogeneity is due to wall friction effects during column preparation, and although the friction reduces the column …

    ut-knoxville Repository record for Application of soil mechanics and the finite element method (FEM) to High Performance Liquid Chromatography (HPLC) columns (opens in a new tab)

  17. The Fabrication And Study Of Metal Chelating Stationary Phases For The High Performance Separation Of Metal Ions

    … of chelating sorbents suitable for the high efficiency separation of trace metals in complex samples, using a single column and isocratic elution, is described. Hydrophobic, neutral polystyrene divinylbenzene resins were either impregnated with chelating dyes or dynamically modified with …

    plymouth Repository record for The Fabrication And Study Of Metal Chelating Stationary Phases For The High Performance Separation Of Metal Ions (opens in a new tab)

  18. Characterization of Mobile Phase Flow Inhomogeneity in Micro-structured Fibres: Towards the Development of Multi-channel Supports for Open Tubular Liquid Chromatography

    Despite the prominent role played by open tubular columns in gas chromatography, they have enjoyed comparatively little success as supports for open tubular liquid chromatography (OTLC), owing to impractical channel diameters (3-5 μm) required to facilitate retention in the liquid phase. In an …

    queens Repository record for Characterization of Mobile Phase Flow Inhomogeneity in Micro-structured Fibres: Towards the Development of Multi-channel Supports for Open Tubular Liquid Chromatography (opens in a new tab)

  19. Investigation of column and instrumental parameters for fast gas chromatography analysis

    … actually being spent on the analysis. Capillary columns are known to be very efficient due to the long lengths and thin stationary phase films. However, analysis can be done much faster if shorter column lengths and thinner stationary phases are used because the retention time is a function of …

    vt Repository record for Investigation of column and instrumental parameters for fast gas chromatography analysis (opens in a new tab)