Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 18 of 18 for “"Combined Chlorine"”
-
Wall Decay Coefficient of Combined Chlorine in a Drinking Water Distribution System
… to calibrate a wall decay coefficient for combined chlorine. Using the least squares method, a unique wall decay coefficient, 0.0295 m/d, was obtained. Using the same method it was found that the wall decay coefficient was 0.0455 m/d for a sub-section of the studied area with predominately …
-
Effects of Activated Carbon on Reactions of Free and Combined Chlorine With Phenols (Chlorination, Gac)
… water treatment results in contact of free or combined chlorine with activated carbon, which is used to remove organic compounds from water. Free chlorine reacts with a group of phenols (phenol, guaiacol, catechol, 2,6-dimethoxyphenol, p-chlorophenol) in dilute aqueous solutions (10('-5)M), to …
-
Modelling the effect of pipe material, water quality and time on chlorine dissipation
… the parameters that influence the rate of chlorine residual dissipation in distribution systems and develop empirical models to predict chlorine residual with time based on those parameters. Groundwater and surface waters were treated utilizing seven different treatment systems (aeration (G …
-
A Comparative Study of Synergistic Effects in Sequential Inactivation of Cryptosporidium Parvum Oocysts and Bacillus Subtilis Spores With Chemical Disinfectants
… of interest for this study were ozone, chlorine dioxide, free chlorine and monochloramine, and the combinations of interest were ozone (or chlorine dioxide) followed by either free or combined chlorine. It is believed that understanding the process of oocyst inactivation by chemical …
-
Formation of (halo)acetamides and (halo)acetonitriles from the reaction of monochloramine and (halo)acetaldehydes in water
… unregulated nitrogen-containing DBPs formed by combined chlorine, such as haloacetonitriles and haloacetamides, might be more toxic than regulated DBPs. Monochloramine has been shown to react with aldehydes, common DBPs formed from ozone and free chlorine disinfection, to form carbinolamines …
-
Impact of Chloramination on the Development of Oligotrophic Biofilms
… reactor, chloramination at 8.5 ± 0.2 mg Cl2/L as combined chlorine was applied after two weeks of biofilm growth till the end of week 10. Confocal laser scanning microscopy combined with quantitative analysis using COMSTAT program revealed that disinfection resulted in a reduction of average …
-
Bacteriophage PRD1 as a potential surrogate for adenovirus in drinking water disinfection with free chlorine, low pressure ultraviolet light, and sunlight
… technologies such as ultraviolet (UV) light, combined chlorine, and solar disinfection. A potential surrogate for adenovirus is the bacteriophage PRD1 because of its similar size, morphology, and genome replication mechanism. The objective of this research was to compare the inactivation …
-
Formation and removal of pesticides and pesticide transformation products during water treatment
… were examined for reactivity including free and combined chlorine, chlorine dioxide, permanganate, ozone, hydrogen peroxide, ultraviolet radiation, and high pH (alkaline hydrolysis). Due to the broad nature of the study, pesticide compounds were analyzed as multiple mixes broken into two groups …
-
Chlorination and Bromination of Nucleobases: the Role of Cytosine and Adenine on the Formation of Disinfection Byproducts
… unregulated nitrogen-containing DBPs (N-DBPs). Chlorine, in the form of hypochlorous acid (HOCl), and in situ disinfectants in the form of hypobromous acid (HOBr or bromine), can react with nitrogenous compounds to produce N-halamines which may serve as precursors to N-DBPs. The present work …
-
Quantifying intra- and extra-cellular Legionella in first-draw and flushed drinking water samples collected across the U.S.
… Legionella spp. concentration was greater in combined chlorine systems than in free chlorine systems, in systems sourced from surface waters than from groundwaters, in first-draw samples than in flushed samples, and putatively extra-cellular to FLA than intra-cellular. To better understand the …
-
An Evaluation on the Chlorine Contact Tank at the Sioux Falls Wastewater Treatment Plant
… to accomplish disinfection of wastewater, chlorine is most commonly used. Chlorine is potent, easily applied and measured, and economical to use. However, some plants utilizing chlorination have had difficulty controlling effluent bacterial quality. This is primarily due to poorly conceived …
-
An Integrated Field-Scale Assessment of Chloramine Dynamics, By-Product Formation, and Nitrification Modeling
… analysis included measurements for: total and combined chlorine, ammonia, nitrite, nitrate, pH, alkalinity, and organic carbon (chloramine dynamics); sulfate (as a pseudo-tracer); N-nitrosodimethylamine (DBP formation); and the absence/presence of ammonia-oxidizing bacteria (AOB) and anaerobic …
-
Innovative Treatment Technologies for Reclaimed Water
… compounds, recently-promulgated regulations on chlorine-resistant microorganisms such as Cryptosporidium parvum, and growth in population and water demand have driven an interest in alternatives to chlorination. The WateReuse Foundation has funded WRF 02-009 (Innovative Treatment Technologies …
-
The Effects of PET-Lined and Epoxy-Coated Lead and Copper Service Lines on Metals Leaching, Total Organic Carbon, and Chlorine Residual in Drinking Water
… on water quality through chemical leaching and chlorine consumption. Fill-and-dump experiments were performed to determine the impact of a commercially available epoxy coating and poly(ethylene terephthalate) (PET) liner on water quality in lead and copper pipes. Forty-five-inch-long pipe …
-
Comparative mechanistic study of Coxsackievirus B5 and Human Adenovirus Serotype 2 inactivation by chlorine
Submission published under a 24 month embargo labeled 'Closed Access', the embargo will last until 2024-12-01
-
Modeling Free Chlorine And Chloramine Decay In A Pilot Distribution System
… inhibitors would have on the rate of free chlorine and chloramine decay in distribution systems. Empirical models were developed to predict the disinfectant residual concentration with time based on the parameters that affected it. Different water treatment processes were used to treat …