Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"Common mode current."”.

  1. Common mode current estimation for cable bundle inside a vehicle

    … 1, it introduces a methodology to simulate the currents and fields during an air discharge ESD into a product by combining a linear description of the behavior of the DUT with a non-linear arc resistance equation. The most commonly used test standard IEC 61000-4-2 requires using contact mode …

    must-thes Repository record for Common mode current estimation for cable bundle inside a vehicle (opens in a new tab)

  2. Innovative applications of TEM cell measurements in predicting radiated emissions due to common-mode current on printed circuit boards

    "Signal voltages and currents in integrated circuits (ICs) and on printed circuit board (PCB) traces produce electric and magnetic fields that can induce common-mode currents on larger radiating structures. In the first part of this dissertation, a TEM cell measurement method employing a hybrid to …

    must-thes Repository record for Innovative applications of TEM cell measurements in predicting radiated emissions due to common-mode current on printed circuit boards (opens in a new tab)

  3. Neutral Point Voltage of Electric Motor for Multilevel Drive in Electric Vehicle

    … in an Electric Vehicle, a high-frequency current is drawn by the electric machine from the inverter which causes conducted emissions. In this thesis, common-mode current and voltage at the AC side of a two-level inverter and a three-level neutral point clamped inverter that are coupled to …

    chalmers Repository record for Neutral Point Voltage of Electric Motor for Multilevel Drive in Electric Vehicle (opens in a new tab)

  4. Switch-mode active EMI filtering

    … amplifiers when designed to filter large ripple currents. This work proposes two different approaches for active EMI filters with a switch-mode amplifier to achieve reduced size and low loss penalty: a high-frequency AEF and a synchronous AEF. The high frequency AEF features a switching amplifier …

    texas Repository record for Switch-mode active EMI filtering (opens in a new tab)

  5. Electromagnetic compatibility in power inverter design

    … emissions. Methods were studied to model these systems and to reduce their emissions. Three topics are presented in this dissertation. Methods were developed to obtain simple SPICE models for complex systems which relate circuit components to physical geometry within the system. …

    must-thes Repository record for Electromagnetic compatibility in power inverter design (opens in a new tab)

  6. Modeling strategies for estimating and suppressing electromagnetic interference and improving power integrity

    … board. Here, simple and accurate inductance models of 2- and 8-terminal capacitors including connections to the power and return plane are developed. Circuit models of the capacitors and layout are created using the partial equivalent element circuit method which provide options for …

    must-thes Repository record for Modeling strategies for estimating and suppressing electromagnetic interference and improving power integrity (opens in a new tab)

  7. Passive Cancellation of Common-Mode Electromagnetic Interference in Switching Power Converters

    It is well known that common-mode (CM) conducted electromagnetic interference (EMI) is caused by the common-mode current flowing through the parasitic capacitance of transistors, diodes, and transformers to ground in the power circuit. Because of the potential for interference with other systems as …

    vt Repository record for Passive Cancellation of Common-Mode Electromagnetic Interference in Switching Power Converters (opens in a new tab)

  8. Multiple Output Power Supply using Toroidal Transformers for Medium Voltage Active Gate Drivers

    … to secondary coupling capacitance to avoid high common mode current, which leads to control signal distortion. For this, a multi-objective optimization design has been performed for the magnetic components of the topology. In this paper, a single input and three output power supply design is …

    arkansas Repository record for Multiple Output Power Supply using Toroidal Transformers for Medium Voltage Active Gate Drivers (opens in a new tab)

  9. Modeling strategy for EMI filter and flyback transformer

    “The switch-mode power supply is key to miniaturizing power adapters. However, the switching nature of the circuit introduces issues in conducted emissions. In a flyback converter, the transformer serves as the path for common mode current flowing from the primary side to the secondary side. …

    must-thes Repository record for Modeling strategy for EMI filter and flyback transformer (opens in a new tab)

  10. Multi-Layer Ultra-Wideband Wilkinson Combiner for Arrays

    … combiner possesses a multilayer design reducing common mode current problems caused by vias. The Wilkinson combiner covers 500 MHz to 3.28 GHz and provides a 6.56:1 bandwidth. It achieves tight impedance matching through stripline coupling. The proposed design provides minimal phase error, equal …

    tamu Repository record for Multi-Layer Ultra-Wideband Wilkinson Combiner for Arrays (opens in a new tab)

  11. Health Monitoring Techniques for High Availability Drives

    … and need for high availability drives in the modern world places high importance on reliability and operational availability. Part of the solution to the increased requirements on availability involves monitoring degradation associated with machine failure, diagnosing the mode of failure and …

    whiterose Download PDF for Health Monitoring Techniques for High Availability Drives (opens in a new tab)

  12. Emulation of Faults in Permanent Magnet Synchronous Machines

    … can suffer from various faults. One of the more common and primarily catastrophic faults in PMSMs is the inter-turn short circuit fault in a stator coil. Hence, PMSM behavior should be studied in the event of this fault. It is essential to have a machine model that is accurate enough to study …

    concordia Download PDF for Emulation of Faults in Permanent Magnet Synchronous Machines (opens in a new tab)

  13. The impact of conventional and wide bandgap semiconductor PWM inverter EDM bearing currents on motor bearings.

    … by electric discharge machining (EDM) bearing currents. This dissertation presents detailed discharge circuit modeling of motor bearing currents, investigates the impact of discharge energy on the damage produced on the bearing race and ball surfaces through the use of a finite element (FE) …

    baylor Repository record for The impact of conventional and wide bandgap semiconductor PWM inverter EDM bearing currents on motor bearings. (opens in a new tab)

  14. Performance Evaluation of Powerline Technology on Low Voltage Distribution Networks

    … data in addition to supplying power. PLT is currently employed to provide data networking in many domestic environments, and is expected to play a major part in the development of the forthcoming Smart Grid. Given that the electrical distribution network was not designed with data …

    the-open-u Download PDF for Performance Evaluation of Powerline Technology on Low Voltage Distribution Networks (opens in a new tab)

  15. INVESTIGATION OF TECHNIQUES FOR REDUCING UNINTENTIONAL ELECTROMAGNETIC EMISSIONS FROM ELECTRONIC CIRCUITS AND SYSTEMS

    … the application of imbalance difference model to various circuit board and cable geometries, and balanced cable interface for reducing common-mode currents from power inverter. The first chapter discusses the importance and the meaning of the connection inductance associated with MLCCs …

    clemson Repository record for INVESTIGATION OF TECHNIQUES FOR REDUCING UNINTENTIONAL ELECTROMAGNETIC EMISSIONS FROM ELECTRONIC CIRCUITS AND SYSTEMS (opens in a new tab)

  16. Design and Validation of a High-Density 10 kV Silicon Carbide MOSFET Power Module with Reduced Electric Field Strength and Integrated Common-Mode Screen

    … ringing and voltage overshoot. An integrated common-mode current screen contains the current that is generated by these fast voltage transients within the power module, rather than flowing to the system ground. This screen connection simultaneously increases the partial discharge inception …

    vt Repository record for Design and Validation of a High-Density 10 kV Silicon Carbide MOSFET Power Module with Reduced Electric Field Strength and Integrated Common-Mode Screen (opens in a new tab)

  17. Design, analysis and operation of hybrid modular multilevel converters for HVDC applications

    … of asymmetrical conditions on the differential-mode current, the common-mode current and sub-module (SM) capacitor voltages, is performed. Based on the analysis, the corresponding control targets and an improved control strategy are designed to improve the operation performance. Considering the …

    strathclyde Repository record for Design, analysis and operation of hybrid modular multilevel converters for HVDC applications (opens in a new tab)

  18. Common Mode Voltage Mitigation Strategies Using PWM in Neutral-Point-Clamped Multilevel Inverters

    … inverters, three-level NPC ASDs produce common-mode voltage (CMV) that can cause motor shaft voltages, bearing currents, and excess voltage stresses on motor windings, resulting in the deterioration of motor bearings and insulation. Furthermore, the CMV and resultant currents can generate …

    marquette Repository record for Common Mode Voltage Mitigation Strategies Using PWM in Neutral-Point-Clamped Multilevel Inverters (opens in a new tab)

Page 1 of 2