Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"Commutation Failure"”.

  1. Commutation Failure Prevention for HVDC Improvement in algorithm for commutation failure prevention in LCC HVDC

    … of such HVDC systems is the high risk of commutation failures when AC disturbances arise. These failures normally develop in the inverter station. When failed commutation occurs, the LCC HVDC system is greatly disturbed resulting in loss of power transmission. Moreover, the rapid increase …

    chalmers Repository record for Commutation Failure Prevention for HVDC Improvement in algorithm for commutation failure prevention in LCC HVDC (opens in a new tab)

  2. Voltage interactions and commutation failure phenomena in multi-infeed HVDC systems

    … with regard to the voltage interactions and the commutation failure phenomena. The in-depth analysis of multi-infeed HVDC systems discussed in this research shows the application of several indices such as the MIIF, MIESCR, and CFII, that can provide researchers and planning engineers in the area …

    manitoba Repository record for Voltage interactions and commutation failure phenomena in multi-infeed HVDC systems (opens in a new tab)

  3. Commutation failure prediction and interaction mechanism of Multi-Infeed LCC-HVDC systems under asymmetrical faults

    … dynamic event in LCC-HVDC inverters, the Commutation Failure (CF) is mostly caused by AC side faults, 70% of which are asymmetrical Single-Line-Ground (SLG) faults, and may cause power transmission cessation, cascading trips, and even blackout. Researchers have studied CF mechanism for …

    birmingham Download PDF for Commutation failure prediction and interaction mechanism of Multi-Infeed LCC-HVDC systems under asymmetrical faults (opens in a new tab)

  4. Modeling line-commutated converter HVDC transmission systems using dynamic phasors

    … of operations such as unbalanced operation and commutation failure. In order to develop the dynamic phasor model of a line-commutated converter, the concept of switching functions is utilized. The developed model is capable of capturing large-signal transients of the system as well as steady …

    manitoba Repository record for Modeling line-commutated converter HVDC transmission systems using dynamic phasors (opens in a new tab)

  5. Investigation of Reactive Power Control and Compensation for HVDC systems

    … fault recovery, Temporary Overvoltage (TOV), and commutation failure. How to quantify the system strength when reactive compensators are connected to the converter bus is investigated. A new series of indices are developed based on the Apparent Short Circuit Ratio Increase (ASCRI). The inertia of …

    manitoba Repository record for Investigation of Reactive Power Control and Compensation for HVDC systems (opens in a new tab)

  6. Extended-frequency dynamic phasor modelling of LCC-HVDC systems for electromagnetic transient simulations

    … operating modes, such as system imbalances and commutation failure, by automatically adjusting its parameters based upon converter terminal quantity measurements. The model offers a high level of accuracy with reduced computational burden as a suitable replacement for conventional switch-based …

    manitoba Repository record for Extended-frequency dynamic phasor modelling of LCC-HVDC systems for electromagnetic transient simulations (opens in a new tab)

  7. •Commutation Methods for SCR-Based Square-Wave Link Inverter

    … need for a dc bus, hence eliminate the need for failure-prone aluminum electrolytic capacitors. Furthermore, SCRs are robust, reliable and cost-effective semiconductor switch devices that needs only a simple gate-pulse to turn on. The SCR device is a rugged device, so the SCR device is well …

    tamu Repository record for •Commutation Methods for SCR-Based Square-Wave Link Inverter (opens in a new tab)

  8. Control and application of VSC-HVDC systems for grid connection

    … as well, such as facing the risk of commutation failure, power reversal taking place by reversal of current direction, reactive power, and active power being not able to be controlled independently, and requirements of costly DC-side and AC-side filters. In order to address those …

    ets-quebec Download PDF for Control and application of VSC-HVDC systems for grid connection (opens in a new tab)

  9. Series / Parallel Hybrid VSC-LCC for HVdc Transmission Systems

    This thesis investigates the feasibility of hybrid converter based arrangements for High Voltage direct current (HVdc) transmission systems. The conventional HVdc transmission systems, which use Line Commutated Converter (LCC) technology, require ac voltage and large amounts of reactive power to …

    manitoba Repository record for Series / Parallel Hybrid VSC-LCC for HVdc Transmission Systems (opens in a new tab)