Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 15 of 15 for “"Components and Cladding"”

  1. Gust effect factors of components and cladding wind loads for low-slope roofs on low-rise buildings

    Accurately predicting the wind loads on components and claddings (C&C) on roofs are important to enhance the resilience of buildings. Wind loads on structures can be estimated by mainly two methods in the prevalent building codes. The first method is to provide peak pressure coefficients which have …

    uwo Repository record for Gust effect factors of components and cladding wind loads for low-slope roofs on low-rise buildings (opens in a new tab)

  2. REEVALUATION OF ASCE 7-10 EXTERNAL PRESSURE COEFFICIENTS ON THE COMPONENTS AND CLADDING OF LOW-RISE BUILDINGS USING MODERN WIND TUNNEL TESTING DATA

    … the external pressure coefficients (GCp) on the components and cladding of low-rise buildings using modern aerodynamic wind tunnel databases. Pressure tap time history data is used to calculate the peak pressure coefficients for a comprehensive sweep of arbitrarily selected grid areas, over all …

    maryland Repository record for REEVALUATION OF ASCE 7-10 EXTERNAL PRESSURE COEFFICIENTS ON THE COMPONENTS AND CLADDING OF LOW-RISE BUILDINGS USING MODERN WIND TUNNEL TESTING DATA (opens in a new tab)

  3. Finite Element Analysis of Carbon Fiber Reinforced Polymer Emergency Shelters

    … materials, sustainable mobile design solutions, and analysis of extreme wind forces on an emergency shelter. The goal of this research is to develop a versatile, lightweight, strong, and economic emergency shelter which could withstand category five hurricane forces using linear finite element …

    ohiolink Repository record for Finite Element Analysis of Carbon Fiber Reinforced Polymer Emergency Shelters (opens in a new tab)

  4. Economical design considerations for one-way 300 foot span, steel, parallel top & bottom chord warren trusses

    … is a parametric study of the different design and construction aspects for a 300’-0” span, steel, Warren type truss. The study specifically examines the vertical loading on the truss, including components and cladding wind loading. The engineering variables investigated are panel point …

    ksu Repository record for Economical design considerations for one-way 300 foot span, steel, parallel top & bottom chord warren trusses (opens in a new tab)

  5. Sensitivity of Steel Purlins to Changes in Application of Wind Loads

    … loading provisions. The National Institute of Standards and Technology (NIST) database of low-rise building wind tunnel test data, which was collected at the University of Western Ontario (UWO) boundary layer wind tunnel, was used to model a realistic wind load scenario. Pressure coefficient data …

    vt Repository record for Sensitivity of Steel Purlins to Changes in Application of Wind Loads (opens in a new tab)

  6. The performance of low-rise open span heavy steel structures in extreme winds

    … to extreme wind events such as hurricanes and tornadoes. The wind velocities in these events either approached or slightly exceeded the normal design values specified in ASCE 7-95. This report focuses specifically on the performance of heavy steel structures and does not include …

    nps Repository record for The performance of low-rise open span heavy steel structures in extreme winds (opens in a new tab)

  7. Post-Charley Evaluation of Undamaged Homes in Punta Gorda Isles

    Hurricane Charley was the third named storm and the second major hurricane of the 2004 Atlantic hurricane season. At that time, it was also the strongest hurricane to strike the US coast since 1992. Charley made landfall on Friday, August 13, 2004 on the barrier islands off Lee County, Florida …

    usf Repository record for Post-Charley Evaluation of Undamaged Homes in Punta Gorda Isles (opens in a new tab)

  8. Experimental Evaluation of ABL and Downburst Wind Loads on an Elevated Building

    Elevated low-rise buildings are vulnerable to cladding damage underneath the structure due to extreme winds and the absence of proper wind loading codes and standards such as the National Building Code of Canada (NBCC). The space between the ground and the horizontal base surface of an elevated …

    uwo Repository record for Experimental Evaluation of ABL and Downburst Wind Loads on an Elevated Building (opens in a new tab)

  9. Comprehensive study of wind loads on parapets

    The current thesis aims at defining and evaluating the local (components and cladding) wind loads on parapets. For the first time, it was attempted to measure such loads in full-scale, in order to address the issues encountered in previous wind tunnel studies. Field testing was carried out using …

    concordia

  10. Atmospheric Boundary Layer Processes To Mimic Peak Pressures on Low-Rise Buildings: CFD Versus Full-Scale and Wind Tunnel Measurements

    … was employed to obtain wind loads on buildings and other structures. However, there is still doubt in the wind engineering community regarding the adequacy of wind tunnels to predict accurately full-scale pressures on low-rise buildings and small-size structures. The recommendations of the …

    lsu-thes Repository record for Atmospheric Boundary Layer Processes To Mimic Peak Pressures on Low-Rise Buildings: CFD Versus Full-Scale and Wind Tunnel Measurements (opens in a new tab)

  11. Finite element analysis and field observation of a residential roof subjected to hurricane winds

    … disasters take a great toll on the economy and infrastructure of the United States. When specifically considering the insured property losses of U.S. natural disasters, seven out of ten highest natural disasters are caused by a hurricane event. Hurricane seasons have increased in activity …

    iastate Repository record for Finite element analysis and field observation of a residential roof subjected to hurricane winds (opens in a new tab)

  12. A Damage Assessment and Wind Loading Analysis of Residential Structures Built Post-1996 in Punta Gorda in the Wake of Hurricane Charley

    … assessment could be made of the area’s homes, and how they stood up to the storm. This study focused further on homes built after major changes to the local/state building codes went into effect (starting in 1996) after the devastation left in south Florida by Hurricane Andrew in 1992. After …

    usf Repository record for A Damage Assessment and Wind Loading Analysis of Residential Structures Built Post-1996 in Punta Gorda in the Wake of Hurricane Charley (opens in a new tab)

  13. Considerations for the Tornado-Resilient Structural Design of Low-Rise Buildings

    Building codes and standards have begun to incorporate tornado-specific loads to help protect community infrastructure against these potentially devastating storms, with a specific focus on low-rise buildings. The current tornado design loads are derived from atmospheric boundary layer (ABL) winds, …

    uwo Repository record for Considerations for the Tornado-Resilient Structural Design of Low-Rise Buildings (opens in a new tab)

  14. Wind Loading Analysis of Standing Seam Metal Roofs on Low-Rise Buildings

    Standing seam metal roofs (SSMR) are a roofing system made up of prefabricated panels secured to the underlying structural purlins using concealed clips. The present study sought to develop a simplified code-approach for evaluating SSMRs. A model of the wind field and wind loads was validated using …

    uwo Repository record for Wind Loading Analysis of Standing Seam Metal Roofs on Low-Rise Buildings (opens in a new tab)

  15. Analysis of Standing Seam Metal Roofs Subjected to Extreme Wind Loads

    Standing seam metal roof (SSMR) systems are widely used in low-rise buildings. This study aims to understand the behavior of SSMR systems, especially the failure mechanisms, under severe wind loads. Full-scale experiments conducted at Insurance Research Lab for Better Homes make it possible to …

    uwo Repository record for Analysis of Standing Seam Metal Roofs Subjected to Extreme Wind Loads (opens in a new tab)