Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"Composite fouling"”.

  1. Composite fouling of calcium sulfate and calcium carbonate in a dynamic seawater reverse osmosis unit

    … in batch systems. The present work evaluates composite fouling behavior of CaSO4 and CaCO3 in a dynamic RO unit. The fouling experiments were performed at constant pressure and velocity by a partial recycling mode which permeate was withdrawn from the system during the recirculation of …

    unsw Repository record for Composite fouling of calcium sulfate and calcium carbonate in a dynamic seawater reverse osmosis unit (opens in a new tab)

  2. The mechanisms of composite fouling in Australian sugar mill evaporators by calcium oxalate and amorphous silica

    … because conventional studies only address fouling by individual components. The present work evaluates their interactions using two experimental approaches: batch tests for assessing kinetic and thermodynamic behaviour, and fouling-loop experiments for examining composite fouling behaviour …

    unsw Repository record for The mechanisms of composite fouling in Australian sugar mill evaporators by calcium oxalate and amorphous silica (opens in a new tab)

  3. The study of pretreatment options for composite fouling of reverse osmosis membranes used in water treatment and production

    … calcium sulphate and silica. However, silica fouling is the recovery limiting factor in RO system. Silica chemistry is complex and its degree of fouling strongly depends on the silica solubility and its polymerization under different operating conditions of RO process. In several studies …

    unsw Repository record for The study of pretreatment options for composite fouling of reverse osmosis membranes used in water treatment and production (opens in a new tab)

  4. Prediction, Diagnosis and Prevention of Fouling in Seawater Reverse Osmosis Membrane Systems.

    … plant was evaluated using both in-situ fouling monitoring methods and theoretical standardisation and normalisation methods. The results showed that overall performance of the plant deteriorated after 6 months of operation due to fouling. In order to determine the identity and cause of …

    whiterose Download PDF for Prediction, Diagnosis and Prevention of Fouling in Seawater Reverse Osmosis Membrane Systems. (opens in a new tab)

  5. Inorganic scaling and its mitigation in geothermal systems

    … which is the formation of the so-called “composite fouling”. It is composed of more than one scaling salts and its composition becomes more complex in more challenging water systems, such as geothermal waters. There have been numerous studies on the inhibition of a single scaling salt and …

    greece Repository record for Inorganic scaling and its mitigation in geothermal systems (opens in a new tab)

  6. CFD modeling of heat exchange fouling

    Heat exchanger fouling is the deposition of material onto the heat transfer surface causing a reduction in thermal efficiency. A study using Computational Fluid Dynamics (CFD) was conducted to increase understanding of key aspects of fouling in desalination processes. Fouling is a complex …

    unsw Repository record for CFD modeling of heat exchange fouling (opens in a new tab)