Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 19 of 19 for “"Compressed Sensing reconstruction"”

  1. Compressed Sensing Reconstruction Using Structural Dependency Models

    Compressed sensing (CS) theory has demonstrated that sparse signals can be reconstructed from far fewer measurements than suggested by the Nyquist sampling theory. CS has received great attention recently as an alternative to the current paradigm of sampling followed by compression. Initial CS …

    arizona-thes Repository record for Compressed Sensing Reconstruction Using Structural Dependency Models (opens in a new tab)

  2. Accelerated Imaging Using Partial Fourier Compressed Sensing Reconstruction

    … been formalized in recent years, and is known as Compressed Sensing (CS). In this dissertation, we developed a new image reconstruction method, Partial Fourier Compressed Sensing (PFCS), which combines the advantages of partial Fourier transform and compressed sensing techniques. Then, we explore …

    maryland Repository record for Accelerated Imaging Using Partial Fourier Compressed Sensing Reconstruction (opens in a new tab)

  3. Subspace informed compressed sensing reconstruction techniques for diffusion tensor imaging

    … that voxel. There is increasing use of iterative reconstruction algorithms of MRI data using the principles of compressed sensing (CS) that rely on the sparsity of information in the image domain to improve reconstructions of undersampled MRI data. Further refinements to the CS algorithm not only …

    ubc Repository record for Subspace informed compressed sensing reconstruction techniques for diffusion tensor imaging (opens in a new tab)

  4. An Efficient Framework for Compressed Sensing Reconstruction of Highly Accelerated Dynamic Cardiac MRI

    … resolution as well as the image quality of the reconstruction cine images. This work focuses primarily on image reconstruction techniques utilized in cine imaging; however, the techniques discussed are also relevant to other dynamic and static imaging techniques based on cardiac magnetic …

    ohiolink Repository record for An Efficient Framework for Compressed Sensing Reconstruction of Highly Accelerated Dynamic Cardiac MRI (opens in a new tab)

  5. Nonlocal and Randomized Methods in Sparse Signal and Image Processing

    … non-local data models to perform tasks such as compressed-sensing reconstruction, image compression, and image denoising. The contributions in this thesis are: (1) a fast, approximate minimum mean-squared error (MMSE) estimation algorithm for sparse signal reconstruction, called Randomized …

    arizona-thes Repository record for Nonlocal and Randomized Methods in Sparse Signal and Image Processing (opens in a new tab)

  6. Towards Comprehensive Mapping of Lung Function Using Hyperpolarized 129Xe MRI: Developments and Applications

    … digital phantom simulations to fine-tune keyhole reconstruction methods and establish robust healthy reference values. The refined methods are then applied to patients with chronic thromboembolic pulmonary hypertension (CTEPH) before and after pulmonary thromboendarterectomy (PTE), a surgical …

    duke Repository record for Towards Comprehensive Mapping of Lung Function Using Hyperpolarized 129Xe MRI: Developments and Applications (opens in a new tab)

  7. Improved methods for preclinical 4D flow magnetic resonance imaging of the aortic arch

    … each other. A combined parallel imaging and compressed sensing reconstruction was implemented that allows to reduce measurement time to 32 minutes with an isotropic resolution of 138 μm. An interactive application was developed to analyze and quantify the acquired velocity data. As a proof of …

    freiburg-diss Repository record for Improved methods for preclinical 4D flow magnetic resonance imaging of the aortic arch (opens in a new tab)

  8. Imaging cerebrovascular health using 7T MRI

    … acquisition of high-resolution MRA using compressed sensing reconstruction. This facilitates the visualization of the small intracranial arteries which are involved in lacunar infarcts and vascular dementia, which can be achieved within clinical scan times.</p> <p>The final parts of this …

    oxford Repository record for Imaging cerebrovascular health using 7T MRI (opens in a new tab)

  9. Predictive Motion Observation and Tracking for Dynamic and Real-Time Cardiac Magnetic Resonance Imaging

    … and tracking (PMOT) that ensures cardiac image reconstruction fidelity without sacrificing spatial resolution, temporal resolution, or volume coverage. In Chapter 1, we define dynamic and real-time rapid cardiac CINE MRI. We subsequently identify the inability of established methods to …

    toronto-retro Repository record for Predictive Motion Observation and Tracking for Dynamic and Real-Time Cardiac Magnetic Resonance Imaging (opens in a new tab)

  10. Transition between Flow Regimes in Porous Media Using Magnetic Resonance Velocimetry: From Laminar to Turbulent

    … further accelerated by combining subsampling and compressed sensing reconstruction. In a random sphere packing column with column-to-diameter ratio of 3.44, the inertial effect and the onset of unsteady regime were examined with respect to the principal flow characteristics: the inertial …

    cambridge Repository record for Transition between Flow Regimes in Porous Media Using Magnetic Resonance Velocimetry: From Laminar to Turbulent (opens in a new tab)

  11. Experimental characterisation of bubbly flow using MRI

    … to a Reynolds number of 12,000. By employing a compressed sensing reconstruction, images were acquired at a rate of 188 fps. Images were then acquired of bubbly flow for the entire range of voidages for which bubbly flow was possible (up to 40.8%). Measurements of bubble size distribution and …

    cambridge Repository record for Experimental characterisation of bubbly flow using MRI (opens in a new tab)

  12. Compressed Sensing Based Reconstruction Algorithm for X-ray Dose Reduction in Synchrotron Source Micro Computed Tomography

    … degrade the image quality. According to the compressed sensing theory, a signal can be accurately reconstructed from highly undersampled data by solving an optimization problem, provided that the signal can be sparsely represented in a predefined transform domain. Therefore, this thesis is …

    sask Repository record for Compressed Sensing Based Reconstruction Algorithm for X-ray Dose Reduction in Synchrotron Source Micro Computed Tomography (opens in a new tab)

  13. Digital Rock: Understanding the mechanism of Enhanced Oil Recovery (EOR) Core Floods

    … under-sampling of the k-space. The parameters of compressed-sensing reconstruction were optimised giving results of high quality. Combining the velocity maps with 3D spatially-resolved propagators without pore-scale resolution enabled the identification of the mechanisms of mechanical and …

    cambridge Repository record for Digital Rock: Understanding the mechanism of Enhanced Oil Recovery (EOR) Core Floods (opens in a new tab)

  14. Distributed image and video coding based on compressed sensing : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Computer Engineering at Massey University, New Zealand

    … coding which is based on the theory of compressed sensing and distributed coding. Compressed sensing is a relatively new theory for the acquisition of sparse signals that allows the sampling rate to be much lower than the Nyquist limit. Distributed coding is based on the theorem by …

    massey Repository record for Distributed image and video coding based on compressed sensing : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Computer Engineering at Massey University, New Zealand (opens in a new tab)

  15. On-board Image Augmentation Using Prior Image and Deep Learning for Image-guided Radiation Therapy

    … from repeated 3D/4D CBCT scans. Low dose CBCT reconstruction is changeling because of streak artifacts caused by limited projection and increased noise by low exposure. Previous methods such as compressed sensing method can successfully remove streak artifacts and reduce noise. However, the …

    duke Repository record for On-board Image Augmentation Using Prior Image and Deep Learning for Image-guided Radiation Therapy (opens in a new tab)

  16. Ultra-fast magnetic resonance imaging for small animal models

    … time sequence with ultra-fast acquisition and compressed sensing reconstruction is developed. The method successfully removed the flow turbulence artifacts in the mouse cardiac images at the early diastolic period. In this study, the ultra-short echo time sequence is further improved with …

    missouri Repository record for Ultra-fast magnetic resonance imaging for small animal models (opens in a new tab)

  17. Patient-specific prospective respiratory motion correction in cardiovascular MRI.

    … down sampled and reconstructed with compressed sensing at R = 4. Frames were then registered (PROCO-R and FB-R) using non-rigid image registration, and an ROI was placed in the basal-anterior, basal-lateral and mid inferolateral segments for the 2-chamber, 4-chamber and short axis …

    ohiolink Repository record for Patient-specific prospective respiratory motion correction in cardiovascular MRI. (opens in a new tab)

  18. Techniques d'acquisitions et reconstructions IRM rapides pour améliorer la détection du cancer du sein

    … d’une séquence IRM permettant à la fois la reconstruction classique d’images, telle que celle utilisée en routine clinique pour le diagnostic, ainsi qu’une reconstruction accélérée d’images avec une plus haute résolution temporelle permettant ainsi l’application de modèles …

    star-france Repository record for Techniques d'acquisitions et reconstructions IRM rapides pour améliorer la détection du cancer du sein (opens in a new tab)