Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 14 of 14 for “"Compression plates"”.

  1. A Comparison of Dynamic Compression Plates and Locking Compression Plates Using Cantilever Bending in a Canine Ilial Fracture Model

    … and stabilized with either a 6-hole Dynamic Compression Plate applied in compression or a 6-hole Locking Compression Plate. Pelves were tested in cantilever bending to failure and construct stiffness, yield load, ultimate load at failure, displacement at failure, and mode of failure compared. …

    guelph Repository record for A Comparison of Dynamic Compression Plates and Locking Compression Plates Using Cantilever Bending in a Canine Ilial Fracture Model (opens in a new tab)

  2. Ex vivo biomechanical comparison of reinforced locking plate design and locking compression plates applied in comminuted tibial fractures

    … of study was to compare four designs of locking plates at biomechanical characteristics for the stabilization of experimentally induced comminuted tibial fractures in dog. Material and Methods: Pelvic limbs were harvested from sixteen dog cadavers. Paired tibiae were stripped of all soft tissues, …

    brazil-ufv Repository record for Ex vivo biomechanical comparison of reinforced locking plate design and locking compression plates applied in comminuted tibial fractures (opens in a new tab)

  3. Dynamisierung der Cis-Kortex durch Einsatz von "Dynamic Locking Screws" in einer mit "Locking compression plates" fixierten Tibiaquerosteotomie: eine experimentelle Studie an Schafen

    Bei der vorliegenden Tierstudie wurden zwei dynamische Kopfverriegelungsschrauben (DLS und FCL) evaluiert und mit einer herkömmlichen Kopfverriegelungsschraube (LS) verglichen. Die 5.0 DLS Schraube ermöglicht durch ihr Design eine Mikrobewegung von 0.35mm und beeinflusst dadurch die Steifigkeit des …

    zurich

  4. Análisis de costo efectividad del uso de la placa de compresión dinámica versus clavo intramedular bloqueado para la fractura proximal de humero en adultos en Colombia

    … in older adults. Fixation through the dynamic compression plate is the most common surgical treatment, but it is associated with high complication rates. Intramedullary blocked nails become an attractive treatment alternative; However, its effectiveness is not yet clear. In order to feed the …

    rosario Repository record for Análisis de costo efectividad del uso de la placa de compresión dinámica versus clavo intramedular bloqueado para la fractura proximal de humero en adultos en Colombia (opens in a new tab)

  5. The Effect of Locking Head Inserts on the Biomechanical Properties of a 3.5 mm Broad Locking Compression Plate when used in an Open Fracture Gap Model

    Locking compression plates (LCP) have gained increasing popularity in veterinary and human medicine for their versatility, combining the functions of both locking and conventional plating systems. LCP are frequently used in minimally invasive plate osteosynthesis (MIPO). MIPO aims to preserve …

    guelph Repository record for The Effect of Locking Head Inserts on the Biomechanical Properties of a 3.5 mm Broad Locking Compression Plate when used in an Open Fracture Gap Model (opens in a new tab)

  6. Finite Element Studies of an Embryonic Cell Aggregate under Parallel Plate Compression

    … embryonic cells is compressed between parallel plates, the cell mass and the cells of which it is composed flatten. Over time, the cells typically move past one another and return to their original, spherical shapes, even during sustained compression, although the profile of the aggregate …

    waterloo Repository record for Finite Element Studies of an Embryonic Cell Aggregate under Parallel Plate Compression (opens in a new tab)

  7. MODEL-BASED DEFORMABLE REGISTRATION OF MRI BREAST IMAGES WITH ENHANCED FEATURE SELECTION

    … domain using the method of finite elements. The compression of the preoperative image is modeled by applying smooth forces on the surface of the breast where compression plates are placed. Image registration is accomplished by formulating and solving an optimization problem. The cost function is …

    mcmaster Repository record for MODEL-BASED DEFORMABLE REGISTRATION OF MRI BREAST IMAGES WITH ENHANCED FEATURE SELECTION (opens in a new tab)

  8. Cold-formed steel compression members with perforations

    … steel (CFS) members subjected to axial compression loading.</p> <p>Cold-formed steel sections are widely used nowadays as primary and secondary framing members in low-rise steel buildings. Although CFS members are essentially thin-walled framing elements, with a major susceptibility to …

    mcmaster Repository record for Cold-formed steel compression members with perforations (opens in a new tab)

  9. Biomechanical Evaluation of Two Methods of Humeral Shaft Fixation

    Biomechanical evaluations of fracture fixation devices attempt to determine implant performance by approximating the in vivo conditions. This performance is affected by many factors and relies on the complex bone-implant interface. Biomechanical tests can be designed in a variety of ways in order …

    clemson Repository record for Biomechanical Evaluation of Two Methods of Humeral Shaft Fixation (opens in a new tab)

  10. Exploration of strategies to promote fracture healing and prevent atrophic non-union in a clinical relevant model

    … nails were stronger and stiffer than compression plates and external fixators. Next, a model of tibial atrophic non-union was established using intramedullary nail fixation, in which a non-critical gap of 1 mm was created in the tibial mid-shaft. To maintain this gap, a specialised …

    edinburgh Repository record for Exploration of strategies to promote fracture healing and prevent atrophic non-union in a clinical relevant model (opens in a new tab)

  11. Tissue Stabilization in MRI-Guided Breast Biopsy

    … by firmly compressing it between two parallel plates. However, high compression forces causes significant patient discomfort and can reduce the intake of the contrast agent, which negatively impact the image quality.</p> <p>This thesis introduces devices and control methodologies for active …

    mcmaster Repository record for Tissue Stabilization in MRI-Guided Breast Biopsy (opens in a new tab)

  12. The Tissue Response to Infectious Burden and Implantable Devices in Healthy and Diabetic Animal Models

    … healthy animal model, control stainless steel compression plates and plates coated with a nitric-oxide releasing xerogel (20% AHAP) were attached to the femurs of 12 adult rabbits. Both femurs were inoculated with 3x106 CFU MSSA (methicillin-sensitive Staph aureus) for a period of 20 minutes …

    duke Repository record for The Tissue Response to Infectious Burden and Implantable Devices in Healthy and Diabetic Animal Models (opens in a new tab)

  13. The Buckling of a Uniformly Compressed Plate with Intermediate Supports

    This problem has been selected from the mathematical theory of elasticity. We consider a rectangular plate of thickness h, length a, and width b. The plate is subjected to compressive forces. These forces act in the neutral plane and give the plate a tendency to buckle. However, this problem …

    unt Repository record for The Buckling of a Uniformly Compressed Plate with Intermediate Supports (opens in a new tab)