Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 21 for “"Compton Camera"”.
-
Optimizing Compton camera performance
… approach is used to study the behavior of the Compton camera in this thesis than previous studies to date. The Compton camera differs from gamma cameras in that the collimator is replaced by a detector known as the ‘scatterer’. Gamma rays may be Compton scattered in the scatterer and …
-
Compton Camera Imaging and the Cone Transform
… inversion of an integral transform (cone or Compton transform) that maps a function to its integrals over conical surfaces with a weight equal to some power of the distance from the cone’s vertex. It arises in various imaging techniques, most prominently, in modeling of the data provided by …
-
Commissioning of a Compton camera for medical imaging
… to develop an in-vivo imaging system based on a Compton camera to verify the particle beam range by detecting (multi-MeV) prompt γ rays, generated as a result of nuclear reactions between the particle beam and biological tissue. In the context of this thesis the prototype of the LMU Compton …
-
Mathematical Problems of Thermoacoustic and Compton Camera Imaging
… a type of emission tomography, called Compton camera imaging is considered. The mathematical problem arising in Compton camera imaging is the inversion of the cone transform. We present three methods for inversion of this transform in two dimensions. Numerical examples of …
-
Coded-Aperture Compton Camera for Gamma-Ray Imaging
… Current designs for large field-of-view gamma cameras suitable for homeland security applications implement either a coded aperture or a Compton scattering geometry to image a gamma-ray source. Both of these systems require large, expensive position-sensitive detectors in order to work …
-
A Compton Camera for In-vivo Dosimetry in Ion-beam Radiotherapy
In dieser Arbeit wird die Bildgebung durch eine Compton-Kamera zur Überwachung der Partikelstrahlentherapie erstmals an der Technischen Universität Dresden untersucht. Die inhärenten Beschränkungen der Methode wurden durch Berechnungen und Monte Carlo Simulationen studiert. Im Zuge dieser …
-
A compton camera prototype with γ-PET imaging capability: from component evaluations to online tests
… der LMU wird ein szintillator-basierter Compton-Kamera-Prototyp mit SiPM-Auslese zur Reichweitenbestimmung von Ionenstrahlen in der Hadronentherapie (mit der Möglichkeit des Einsatzes im γ-PET-Modus) entwickelt. Als Compton-Kamera-Streudetektor wird eine GAGG (Ce:Gd3Al2Ga3O12) …
-
Construction of a compton-camera prototype based on silicon scatterer with analytical image reconstruction for medical imaging
… adopting electronic collimation in the form of a Compton camera configuration. The present PhD study focuses on the construction of a simple prototype imaging device, known as the Compton Camera, free of any mechanical collimation and complying with the Compton kinematic laws. The setup of this …
-
Development and performance evaluation of detectors in a Compton camera arrangement for ion beam range monitoring in particle therapy
… monitoring are worldwide being evaluated. The Compton camera is one of the proposed techniques, which aims at providing real-time, in-vivo proton (or ion) beam range monitoring by means of the detection of secondary prompt gamma rays, resulting from nuclear reactions between the particle beam …
-
Properties of Some Integral Transforms Arising in Tomography
… tomography, photoacoustic tomography, and Compton camera imaging. Each of these tomographic techniques leads to a Radon-type transform: radio tomography brings about an elliptical Radon transform, single scattering optical tomography reduces to the V-line Radon transform, and photoacoustic …
-
Improvement and characterisation of pixelated Cadmium-Zinc-Telluride detectors for use in neutrino-less double-beta decay searches
… the door to operation of the detectors as a ‘Compton Camera’. Accordingly, Geant4 simulations are compared with real-world measurements, to establish the benefits of pixelation upon the operation of the detectors as a ‘Compton Camera’. Finally, comparisons are performed between Geant4 …
-
Instrumentation of CdZnTe detectors for measuring prompt gamma-rays emitted during particle therapy
… be optimized depending on the method (e.g. slit camera, time-of-flight measurement or Compton camera). Regardless of the method, the detector system must have a high count rate capability and a large measuring range (>7 MeV). For a subsequent evaluation of a suitable method for imaging, the …
-
Treatment verification in proton therapy based on the detection of prompt gamma-rays
… spatial prompt gamma-ray emission profile with a Compton camera is investigated with a prototype system consisting of a CdZnTe cross strip detector as scatter plane and three side-by-side arranged, segmented BGO block detectors as absorber planes. In the second part, the novel method of prompt …
-
Reconstructing Functions on the Sphere from Circular Means
… arise in various practical applications like Compton camera imaging, magnetic resonance imaging, photoacoustic tomography, Radar imaging or seismic imaging. Furthermore, we apply our findings about spherical means to the cone-beam transform and prove its singular value decomposition.
-
Nuclear methods for real-time range verification in proton therapy based on prompt gamma-ray imaging
… Gamma-ray Imaging (PGI) are investigated: the Compton camera (Cc) and the Prompt Gamma-ray Timing (PGT). Their applicability in a clinical scenario is discussed and compared. The first method aspires to reconstruct the prompt gamma ray emission density map based on an iterative imaging …
-
Pixel detector with exotic sensors: device characterisation, analysis, and application
… detector with a high-Z sensor as a single-layer Compton camera. Proof of concept was demonstrated in a very thin (1mm thick), 55 µm pitch CdTe bonded to a Timepix3 readout ASIC. Despite limited data, an image depicting the origin of a gamma-ray source was fully reconstructed just by utilising the …
Page 1 of 2