Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 5 of 5 for “"Compton Edge"”

  1. Gamma Calibration of Scintillators for the MUon Scattering Experiment

    … likelihood in an energy range that covers the Compton edge in the distribution. Final calibration demonstrates the accuracy of this method to within 2 % for the various source measurements at the threshold of the detectors (around 2 MeV).

    south-carolina Repository record for Gamma Calibration of Scintillators for the MUon Scattering Experiment (opens in a new tab)

  2. Electron Dynamics in High-Intensity Laser Fields

    … a substantial redshift of the usual kinematic Compton edge of the photon emission spectrum, caused by the large, intensity dependent effective mass of the electrons inside the laser beam. In addition, we find that the notion of a centre-of-mass frame for a given harmonic becomes intensity …

    plymouth Repository record for Electron Dynamics in High-Intensity Laser Fields (opens in a new tab)

  3. Ραδιολογικός χαρακτηρισμός ενεργοποιημένων τμημάτων αντιδραστήρων

    … based on the analysis of the photopeak and the Compton edge. The first method is based on the net counts of the detector in the photopeak and the Compton edge region arising from the contribution of activities in the volume (due to activation) as well as on the surface (due to radioactive …

    greece Repository record for Ραδιολογικός χαρακτηρισμός ενεργοποιημένων τμημάτων αντιδραστήρων (opens in a new tab)

  4. Evaluation of Thallium Bromide as a Room Temperature Gamma-ray Detector

    … could not be resolved, but the shifting Compton edge illustrated the energy sensitivity of the device. These findings demonstrate that this thesis’ technique for developing energy sensitive TlBr detectors was successful. However, further work needs to be taken to improve charge collection …

    liverpool Repository record for Evaluation of Thallium Bromide as a Room Temperature Gamma-ray Detector (opens in a new tab)

  5. Neutron Spectroscopy in Proton Therapy

    … detector, which was 17% at 477keV (Cs^137 Compton edge). Using a Figure of Merit to evaluate the obtained PSD methods, the best PSD method performance was found to be the charges ratio. Thus, the charges ratio PSD method was applied to the collected data from the measurements at the proton …

    ucl Repository record for Neutron Spectroscopy in Proton Therapy (opens in a new tab)