Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 7 of 7 for “"Compton polarimeter"”.
-
Data Analysis for a Balloon Borne Compton Polarimeter
The Gamma RAy Polarimeter Experiment (GRAPE), a balloon borne Compton polarimeter for 50-500 keV gamma rays, was successfully flown for the second time in 2014. GRAPE uses events in which a photon scatters between 2 detector elements to measure the polarization of the measured photons. GRAPE …
-
Design and Fabrication of A Prototype Fabry-Perot Cavity for the Compton Polarimeter Upgrade at Jefferson Lab
… measurement at 0.85 Ge V energy. The Compton polarimeter at Hall A is capable of measuring beam polarization with 3 - 4 % accuracies at this beam energy. Hence it was proposed to upgrade the present Compton by doubling the laser frequency [2]. The present Compton polarimeter operates …
-
Detector development for the MOLLER experiment
… used for both the integrating detector and the Compton polarimeter. Prototypes of the integrating detectors were assembled and tested using the 855 MeV beam at the Mainz Microtron (MAMI) in Mainz, Germany. A new mounting structure with an integrated cooling system is being developed for the …
-
Thermal analysis and performance validation for in-vacuum operation of Compton HV-MAPS electron detector for the MOLLER Experiment
… Active Pixel Sensors (HV-MAPS) in the Hall A’s Compton polarimeter to monitor the polariza- tion of the incoming beam from the Continuous Electron Beam Acceleration Facility (CEBAF). The HV-MAPS based electron detector contains a quad-planar geometry and each plane incor- porates three HV-MAPS …
-
Linear Polarization Measurements on ²²Na
… and 3.059 MeV levels of ²²Na using a Ge(Li) Compton polarimeter. Consistency with previous measurements on parameters characterizing these levels was first checked before assigning J^π = 2⁺ for the 1.984 MeV level and determining that both 2.969 MeV and 3.059 MeV levels have positive parity. …
-
Tests of a silicon strip detector with the QWEAK amplifier discriminator board (QWAD)
The Hall A Compton Polarimeter at Thomas Jefferson National Accelerator Facility (JLab) utilizes a multi-plane silicon strip detector for determining the overall polarization of an electron beam. Techniques such as Compton polarimetry are an essential part of several particle physics experiments, …
-
An Integrated Study of Instrument Performance and Scientific Yield: Evaluation of the GRAPE Design
… validation of the 3-dimensional Gamma-Ray Polarimeter Experiment (GRAPE), a wide-field-of-view (FoV) Compton polarimeter designed for high-energy astrophysics. The primary scientific motivation is to address unresolved questions in the physics of Gamma-Ray Burst (GRB) jets, for which …