Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 15 of 15 for “"Computational Phantom"”.
-
Advancement of A 3D Computational Phantom and Its Age Scaling Methodologies For Retrospective Dose Reconstruction Studies
We have used a 3D age-scalable computational phantom for over two decades for retrospective dose reconstruction studies of childhood cancer survivors (CCS) treated with 2D historic radiotherapy (RT). However, our phantom and its age scaling functions (ASF) must be updated so that it can be used in …
-
Assessment of imaging dose from the kilovoltage cone beam computed tomography system on board the Varian Halcyon linear accelerator
… Crossline profiles to those measured in a water phantom using calibrated parallel plate and thimble ionisation chambers. In-phantom dose measurements using Radiochromic film in RANDO pelvic and thoracic phantoms were used to generate a Normalisation Factor to relate the measured and simulated …
-
APPLICATIONS OF HEAT AND MASS TRANSFER ANALYSIS IN BIO-MEDICINE AND MATERIALS
… and materials. In the first part we introduce a computational method to simultaneously estimate size, location and blood perfusion of model cancerous breast lesions from surface temperature data. A 2-dimensional computational phantom of axisymmetric tumorous breast with six tissue layers, …
-
Reconstruction Tools and Techniques for Highly Accelerated MRI
… image. A simulated acquisition using a virtual (computational) phantom with a closed form Fourier transform, i.e. analytical phantom, can conveniently provide this gold standard. However, existing virtual phantoms are comprised of simple geometric primitives which cannot accurately model …
-
Overcoming missing ground truth and multi-vendor dependent problems in cardiac valves quantitative evaluation through cardiac magnetic resonance imaging (CMR)
… segmentation model on multi-site 4D flow MRI. A computational phantom incorporating the dynamic closure of the mitral valve was developed from CT data and used to generate synthetic MRI data with different sampling orientations. Manual segmentations of the mitral valve on these images were …
-
A comparison of three computational phantoms for calibration of a radiation portal monitor used for measurement of internal contamination.
… (personnel) measurement time. Three different computational phantoms were considered for this work: the adult male Bottle Mannequin Absorber (BOMAB) phantom, the University of Florida – Oak Ridge National Laboratories (UF-ORNL) stylized phantom, and the International Commission on Radiological …
-
Personal dosimetry of workers without a physical dosemeter using computational methods
… are even higher. On the other hand, computational techniques are evolving rapidly. In the past, simplified mathematical phantoms were used, while now very detailed voxel and mesh phantoms are available. In addition, with increasing computational power, such calculations can be …
-
Development of fibrous structures for brain phantoms
… where a bone is broken. The inexistence of a phantom that rigorously mimics the human brain hinders the possibility of testing, calibrating and validating these medical imaging techniques. Most research in this area suffers from a huge gap in key points, such as the size limit and geometry …
-
Investigation of Subcellular Damage and Long-term Non-Cancerous Cardiovascular Effects Following Whole-Body Photon Irradiation
… through experimental biomarker analysis and computational microdosimetry. The central hypothesis posits that whole-body photon irradiation results in subcellular non-nuclear damage, specifically increased circulating mitochondrial DNA concentrations, that correlates with radiation dose and …
-
Monte-Carlo Calculations for Patient and Staff Dose Management during Fluoroscopically-Guided Procedures
… changes with different exposure parameters and phantoms. Between CAU 30 to CRA 30 degree, at eye level, Caudal results in 20 % higher dose for exposure in the chest region compared to the abdominal region. In general, for both CRA/CAU and LAO/RAO angles, the chest region produces higher scatter …
-
Development and application of enhanced, high-resolution physiological features in XCAT phantoms for use in virtual clinical trials
… and virtual pathologies. Currently, most computational phantom organs and pathologies are segmented or generated from clinical CT images. With this approach, most computational organs and pathologies are necessarily static, comprising only a single instantaneous representation. Further, …
-
Prospective Estimation of Radiation Dose and Image Quality for Optimized CT Performance
… profiles from major CT vendors, and a library of computational phantoms with representative sizes, ages, and genders. The prospective quantification model is validated by comparing the predicted organ dose with the dose estimated based on Monte Carlo simulations with TCM function explicitly …
-
Risk and Risk Factors For Colorectal Subsequent Malignancies In Survivors of Childhood Cancer: A Report From The Childhood Cancer Survivor Study
Survivors of childhood cancer are at risk for colorectal subsequent malignant neoplasms (SMNs); notably, these cancers are amenable to screening. To identify at-risk survivors that may benefit from early screening, descriptive and risk factor analyses were performed to ascertain risk factors for …
-
Infrastructure Development For Personalized Risk Prediction to Reduce Cardiovascular Disease In Childhood Cancer Survivors
… dosimetry from reconstructing survivors’ RT on computational phantoms with a simple heart model. Thus, the main objective of this research was to expand the dose reconstruction infrastructure for late effects studies and enhance the heart model to improve the accuracy of whole heart dosimetry …