Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"Computational phantoms"”.

  1. A comparison of three computational phantoms for calibration of a radiation portal monitor used for measurement of internal contamination.

    … (personnel) measurement time. Three different computational phantoms were considered for this work: the adult male Bottle Mannequin Absorber (BOMAB) phantom, the University of Florida – Oak Ridge National Laboratories (UF-ORNL) stylized phantom, and the International Commission on Radiological …

    uoit Repository record for A comparison of three computational phantoms for calibration of a radiation portal monitor used for measurement of internal contamination. (opens in a new tab)

  2. Application development for personalized dosimetry in pediatric examinations of nuclear medicine based on Monte Carlo simulations and the use of computational models

    … based on Monte Carlo simulations and the use of computational models”, aims to develop and certify innovative personalized dosimetry tools in pediatric nuclear medicine examinations (SPECT, PET, multimodal SPECT/PET/CT), as well as to optimize therapeutic approaches, using Monte Carlo simulations …

    greece Repository record for Application development for personalized dosimetry in pediatric examinations of nuclear medicine based on Monte Carlo simulations and the use of computational models (opens in a new tab)

  3. Quantification and computational modelling of radiation doses while handling Neutron Activation Analysis samples

    … transport. The MCNP 6.2 model is used to computationally irradiate sample materials in several positions in the TRIGA reactor core using various NIST standard reference materials and typical NAA samples. In a second MCNP 6.2 model, two different computational phantoms are modeled: 1) …

    texas Repository record for Quantification and computational modelling of radiation doses while handling Neutron Activation Analysis samples (opens in a new tab)

  4. Infrastructure Development For Personalized Risk Prediction to Reduce Cardiovascular Disease In Childhood Cancer Survivors

    … dosimetry from reconstructing survivors’ RT on computational phantoms with a simple heart model. Thus, the main objective of this research was to expand the dose reconstruction infrastructure for late effects studies and enhance the heart model to improve the accuracy of whole heart dosimetry …

    uthsc Repository record for Infrastructure Development For Personalized Risk Prediction to Reduce Cardiovascular Disease In Childhood Cancer Survivors (opens in a new tab)

  5. Rapid acute dose assessment using MCNP6

    … effects from such doses. Using the reference computational phantoms defined by the International Commission on Radiological Protection (ICRP) and the Monte Carlo N-Particle transport code (MCNP6), dose rate coefficients are calculated to assess doses for common acute doses due to beta and …

    colostate Repository record for Rapid acute dose assessment using MCNP6 (opens in a new tab)

  6. Endorectal Digital Prostate Tomosynthesis

    … to prostate imaging. Experiments using computational phantoms, physical phantoms, and canine prostate specimens were conducted. Initial system design was performed computationally and three methods of endoDPT image reconstruction were developed: shift and add (SAA), backprojection (BP), …

    lsu-thes Repository record for Endorectal Digital Prostate Tomosynthesis (opens in a new tab)

  7. A Method to Determine Patient Eye-Lens Dose During Fluoroscopically-Guided Neuro-Interventional Procedures

    … using National Cancer Institute of CT (NCICT) computational phantoms to create a dataset of lens dose values for the right and left eyes to train the deep learning (DL) models. The dataset was obtained for a range of geometric and exposure parameters used in neuro-interventional procedures …

    buffalo Repository record for A Method to Determine Patient Eye-Lens Dose During Fluoroscopically-Guided Neuro-Interventional Procedures (opens in a new tab)

  8. Dose and Risk Assessment Methods for Epidemiologic Studies Investigating Long-term Side Effects of Proton Therapy

    … combined with the library of body size-dependent computational human phantoms, methods were created to generate a full-body patient-specific phantom. This allows for full-body neutron dose calculations using Monte Carlo radiation transport methods. Second, a computer simulation model was developed …

    tamu Repository record for Dose and Risk Assessment Methods for Epidemiologic Studies Investigating Long-term Side Effects of Proton Therapy (opens in a new tab)

  9. FETUS PHANTOM CONSTRUCTIONS FOR OVERWEIGHT AND OBESE PREGNANT FEMALES FOR RADIOLOGICAL APPLICATIONS

    … project related to the construction of hybrid computational phantoms, including the fetus and the pregnant female with the focus on overweight and obese patients, which can be used in radiological applications. In detail, a series of three hybrid computational fetus phantoms corresponding to a …

    ecu Repository record for FETUS PHANTOM CONSTRUCTIONS FOR OVERWEIGHT AND OBESE PREGNANT FEMALES FOR RADIOLOGICAL APPLICATIONS (opens in a new tab)

  10. Cardio-respiratory motion compensation for radiation dose reduction in X-ray guided cardiac interventions

    … X-ray sequences generated from realistic XCAT computational phantoms with cardio-respiratory motion were first investigated. The simulated motion included the beating heart and respiratory motion. We simulated 56 different patients (32 male and 24 female) and 112 sequences (2 sequences per …

    ets-quebec Download PDF for Cardio-respiratory motion compensation for radiation dose reduction in X-ray guided cardiac interventions (opens in a new tab)

  11. Development and Application of Realistic Anatomical and Imaging Models for Virtual Clinical Trials in Computed Tomography

    … limited clinical trials or simplistic physical phantoms. This projection was outlined in three sections: 1) modeling high-resolution human models with intra-organ heterogeneities, 2) modeling a scanner-specific and realistic computed tomography simulator, and 3) performing a virtual clinical …

    duke Repository record for Development and Application of Realistic Anatomical and Imaging Models for Virtual Clinical Trials in Computed Tomography (opens in a new tab)

  12. Dosimetric investigations of Kilovoltage Cone Beam Computed Tomography (kV-CBCT) utilized in Image Guided Radiation Therapy (IGRT) using Monte Carlo simulations

    … are performed within standard head and body phantoms made of polymethyl methacrylate (PMMA) that are only 150 cm long, which is less than or similar to beam widths used for CBCT scans. Therefore, much of the scatter that would contribute to the dose received by a patient is not recorded. …

    glasgow Download PDF for Dosimetric investigations of Kilovoltage Cone Beam Computed Tomography (kV-CBCT) utilized in Image Guided Radiation Therapy (IGRT) using Monte Carlo simulations (opens in a new tab)

  13. Prospective Estimation of Radiation Dose and Image Quality for Optimized CT Performance

    … profiles from major CT vendors, and a library of computational phantoms with representative sizes, ages, and genders. The prospective quantification model is validated by comparing the predicted organ dose with the dose estimated based on Monte Carlo simulations with TCM function explicitly …

    duke Repository record for Prospective Estimation of Radiation Dose and Image Quality for Optimized CT Performance (opens in a new tab)

  14. Advancement of A 3D Computational Phantom and Its Age Scaling Methodologies For Retrospective Dose Reconstruction Studies

    We have used a 3D age-scalable computational phantom for over two decades for retrospective dose reconstruction studies of childhood cancer survivors (CCS) treated with 2D historic radiotherapy (RT). However, our phantom and its age scaling functions (ASF) must be updated so that it can be used in …

    uthsc Repository record for Advancement of A 3D Computational Phantom and Its Age Scaling Methodologies For Retrospective Dose Reconstruction Studies (opens in a new tab)

  15. Hybrid Reference Datasets for Quantitative Computed Tomography Characterization and Conformance

    … of two distinct modes, (a) anthropomorphic phantoms and (b) clinical images.</p><p>As an alternative to the MTF, the first aspect of this project aimed at validating the task transfer function (TTF), which is a quantitative measure of system resolution. TTF was used as a means to account for …

    duke Repository record for Hybrid Reference Datasets for Quantitative Computed Tomography Characterization and Conformance (opens in a new tab)