Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 44 for “"Concept device"”

  1. INTEGRATED MICROSYSTEM-BASED APPROACH FOR DETECTION AND TREATMENT OF BACTERIAL BIOFILMS ON URINARY CATHETERS

    … infections in situ. Specifically, a proof-of-concept device comprised of gold interdigitated electrodes on a flexible polyimide substrate is fabricated and characterized in vitro. This substrate allows the device to conform seamlessly with the cylindrical surface of a catheter. Real-time …

    maryland Repository record for INTEGRATED MICROSYSTEM-BASED APPROACH FOR DETECTION AND TREATMENT OF BACTERIAL BIOFILMS ON URINARY CATHETERS (opens in a new tab)

  2. HoneyPhy: A physics-aware CPS honeypot framework

    … dressing networking concerns, but also modeling device actuation fingerprints and how the attached process responds to actuations. In order to create a convincing CPS honeypot, a framework was developed to address the need to present convincing networking, device, and process fingerprints. Two …

    gatech Repository record for HoneyPhy: A physics-aware CPS honeypot framework (opens in a new tab)

  3. Design of a Non-contact Home Monitoring System for Audio Detection of Infant Apnea

    … investigates the construction of a proof of concept device that performs in-home monitoring without skin contact and with commonly available off-the-shelf components. The device constructed used a directional microphone to detect breathing sounds, an omnidirectional microphone to detect …

    calpoly Repository record for Design of a Non-contact Home Monitoring System for Audio Detection of Infant Apnea (opens in a new tab)

  4. A Standoff Approach to Monitoring Infant Apnea

    … and brought together for a final proof-of-concept device. The software was developed using LabView and run on a Netbook. Testing was conducted on healthy adults to fine tune the carbon dioxide sensor and measure its response during simulated apnea events. Overnight testing showed that the …

    calpoly Repository record for A Standoff Approach to Monitoring Infant Apnea (opens in a new tab)

  5. Feasibility Study of Concept Designs for Photonic Radiation Detection

    … study on a photonic-based semiconductor concept design for a radiation detector. The research was funded by the National Science Foundation in conjunction with the Department of Homeland Security. It was a cooperative effort between the Nuclear Engineering Program and the Electrical and …

    ohiolink Repository record for Feasibility Study of Concept Designs for Photonic Radiation Detection (opens in a new tab)

  6. Thermodynamic performance evaluation and experimental study of a Marnoch Heat Engine

    … thesis presents a laboratory-scale, proof-of-concept device, which has been built and tested at the University of Ontario Institute of Technology, Canada. It also presents a thermodynamic analysis of the current system. Based on the MHE results, component modifications are made to improve the …

    uoit Repository record for Thermodynamic performance evaluation and experimental study of a Marnoch Heat Engine (opens in a new tab)

  7. A Fully Printed Flexible Electrochemical Dna Sensor with 3d Printed Microfluidics for Sop Lab-on-chip Applications

    … reimagined as compact, low-cost, and disposable devices. Lab-on-chip (LoC) technology sits at the center of this shift, promising to compress the analytical capability of an entire laboratory bench onto a chip only millimeters in scale. Realizing this promise, however, requires the convergence of …

    gatech Repository record for A Fully Printed Flexible Electrochemical Dna Sensor with 3d Printed Microfluidics for Sop Lab-on-chip Applications (opens in a new tab)

  8. A Robotic Head Stabilization Device for Post-Trauma Transport

    … Robot(SAVER) is introduced. The necessity of a device intended to support the head and cervical spine during transport on a rescue robot is then discussed. The kinematic and dynamic analyses of various candidate differential mechanisms intended for the head stabilization device are described, …

    vt Repository record for A Robotic Head Stabilization Device for Post-Trauma Transport (opens in a new tab)

  9. Compact silicon diffractive sensor: design, fabrication, and functional demonstration

    … was functionally demonstrated. The proof-of-concept device includes a polymer immobilization layer and microfluidic delivery of toluene. Toluene concentrations as low as 100ppm are measured, corresponding to a refractive index change of 3x10⁻⁴ RIU.

    gatech Repository record for Compact silicon diffractive sensor: design, fabrication, and functional demonstration (opens in a new tab)

  10. The development of an adaptive and reactive interface system for lower limb prosthetic application

    … on the cells. To achieve this, a proof-of-concept device was designed and manufactured, a system that allowed the change in displacement of a magnet to be responded to by counterbalancing load. The device was evaluated through experimentation on an able-bodied subject wearing an orthotic …

    strathclyde Repository record for The development of an adaptive and reactive interface system for lower limb prosthetic application (opens in a new tab)

  11. A low-cost laser grooved interdigitated back contact solar cell

    … efficiency silicon solar cells. These current devices have yet to become the market leading technology due to the costly and tricky fabrication processes required to keep the doped regions of the p/n junction separate from each other whilst being on the same side of the wafer. This project will …

    soton Repository record for A low-cost laser grooved interdigitated back contact solar cell (opens in a new tab)

  12. DESIGN AND FABRICATION OF AN ADVANCED EXOSKELETON FOR GAIT RESTORATION

    … increasing performance over a previous proof of concept device. The initial device was invented to provide a method of gait restoration to individuals with paraplegia. It combines two different ideas – functional electrical stimulation of the user’s muscles, and an external, hydraulically …

    ohiolink Repository record for DESIGN AND FABRICATION OF AN ADVANCED EXOSKELETON FOR GAIT RESTORATION (opens in a new tab)

  13. A security architecture for medical application platforms

    The Medical Device Coordination Framework (MDCF) is an open source Medical Application Platform (MAP) that facilitates interoperability between heterogeneous medical devices. The MDCF is designed to be an open test bed for the conceptual architecture described by the Integrated Clinical Environment …

    ksu Repository record for A security architecture for medical application platforms (opens in a new tab)

  14. In-vacuum roll-to-roll patterning for functional devices

    … for application to functional organic devices. </p> <p>The integral thermal mechanism of this process, called selective metallization, is modelled, showing its compatibility with functional organics (process temperature <60°C, Al sheet resistance <1.59Ω◻<sup>-1</sup>}). The first …

    oxford Repository record for In-vacuum roll-to-roll patterning for functional devices (opens in a new tab)

  15. Untersuchung des elektronischen Transports an 28nm MOSFETs und an Schottky-Barrieren FETs aus Silizium-Nanodrähten

    … have to be overcome in order to further increase device performance, enabling highspeed and ultra-low-power applications. With progressive scaling of Silicon MOSFETs, charge carrier mobility has dropped significantly and became a critical device parameter over the last decade. Present technology …

    qucosa-diss Repository record for Untersuchung des elektronischen Transports an 28nm MOSFETs und an Schottky-Barrieren FETs aus Silizium-Nanodrähten (opens in a new tab)

  16. Flexible low-cost wireless temperature sensor using thermoresponsive Y5V capacitor chips

    … fabricates, and demonstrates the first proof-of-concept device of a flexible wireless sensor that uses Y5V capacitor chips in combination with planar inductive coils microfabricated on thin polymer film, forming LC-tank-based devices. The physical flexibility and disposable nature of the devices …

    ubc Repository record for Flexible low-cost wireless temperature sensor using thermoresponsive Y5V capacitor chips (opens in a new tab)

  17. Microsystems Integration Towards Point-of-Care Monitoring of Clozapine Treatment for Adherence, Efficacy, and Safety

    … biomarkers in whole blood samples. This proof-of-concept device lays the foundation for a fully integrated and automated lab-on-a-chip for point-of-care or even at-home testing to ensure treatment adherence, efficacy, and safety. This will allow for broader use of clozapine by increasing …

    maryland Repository record for Microsystems Integration Towards Point-of-Care Monitoring of Clozapine Treatment for Adherence, Efficacy, and Safety (opens in a new tab)

  18. Flight Test Data System for Strain Measurement

    … describes the design and evaluation of two devices to be included in the next generation of the family of devices called the Boundary Layer Data System (BLDS). The first device, called the Quasi-Static Strain Data Acquisition System, is a continuation of the BLDS-M series of devices to be …

    calpoly Repository record for Flight Test Data System for Strain Measurement (opens in a new tab)

  19. Investigating magnetisation dynamics in magnetic thin films and micro-structures

    … effects is exploited here to showcase a proof of concept device which can be used as another method to aid in the study of magnetisation dynamics. GMR’s resistance response is dependent on the relative orientations of magnetisation between the free layer and the pinned layer. The AMR’s resistance …

    durham Repository record for Investigating magnetisation dynamics in magnetic thin films and micro-structures (opens in a new tab)

  20. Terahertz difference frequency generation quantum cascade lasers with improved terahertz out-coupling efficiency

    … of Ⅲ-Ⅴ-on-silicon hybrid semiconductor laser concept to Cherenkov THz DFG-QCLs improves THz out-coupling efficiency owing to the smaller refractive index and THz absorption of float-zone high-resistivity silicon (FZ HR Si) substrate used in these devices than S.I. InP substrate. The …

    texas Repository record for Terahertz difference frequency generation quantum cascade lasers with improved terahertz out-coupling efficiency (opens in a new tab)

Page 1 of 3