Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 134 for “"Concrete Block"”.
-
Seismic behavior of concrete block masonry buildings
… to medium rise residential buildings, based on concrete block masonry units and truss type reinforcement, the main objective of the present work is to study the seismic behavior of masonry buildings built with this system. For this, an enlarged experimental campaign and numerical analysis were …
-
Concrete block masonry construction to resist severe winds
Unreinforced masonry is a common construction system for low-rise commercial buildings. It is often used as load-bearing wall system in large low-rise buildings such as malls, warehouse and industrial buildings. Failure of such construction type is prevalent during severe windstorm events such as …
-
Numerical Modelling of Hollow Concrete Block Masonry Mechanics
… masonry elements causes the mechanics of hollow concrete masonry to not be fully understood. To gain a better understanding of hollow concrete masonry mechanics, this thesis presents three numerical models to describe these mechanics from the micro to the macro level.The Smeared Area Compression …
-
Capacity of Eccentrically Loaded Slender Concrete Block Walls
<p> The behavior of concrete block walls subjected to vertical compressive loads with out-of-plane eccentricities was investigated both experimentally and analytically. Particular attention was devoted to the effect of wall slenderness on capacity.</p> <p> In the experimental study, 14 full scale …
-
Short and Long Term Capacities of Slender Concrete Block Walls
<p>Short and long term capacities of slender concrete block masonry walls subject to eccentric axial loads were investigated. A finite element model was developed to include both the geometric and the material nonlinearities. To analyze large members, a combined macro-micro finite element model for …
-
Seismic Performance Assessment of Ductile Reinforced Concrete Block Structural Walls
… investigated the seismic performance of six concrete block structural walls in an effort to evaluate their force-, displacement- and performance- based seismic design parameters. The walls fall under the ductile shear wall/special reinforced wall seismic force resisting system (SFRS) …
-
Behaviour of Reduced-Scale Fully-Grouted Concrete Block Shear Walls
… a decision was made to make use of scaled concrete blocks and proportionately scaled walls to conduct shear wall research over a range of wall sizes representative of walls in buildings. Half scale units have been used at McMaster University for the past 6 years and the research presented …
-
Behaviour of Reduced-Scale Fully Grouted Concrete Block Masonry Building
… test program, testing utilizes one-third scale concrete blocks.<br /><br />This thesis focuses on the ductile response of a one-third scale reinforced, fully grouted, concrete block shear wall building. As the name implies, the lateral load resisting system consists solely of reinforced masonry …
-
Out-of-plane behaviour of concrete block walls with unbonded reinforcement
… span between lateral support levels. Reinforced concrete block walls constructed in this manner can typically span at least two stories in constrast to the limited single storey capacity of unreinforced walls. However, the use of grout as needed for the construction of these walls increases their …
-
In-Plane Core Fill Strengthening of Concrete Block Masonry Shear Walls
… the observed poor performance of unreinforced concrete block masonry walls in recent earthquakes, there is significant demand in Canada and internationally for economical methods to improve the seismic performance of such walls. Common retrofit methods such as the application of external fibre …
-
Investigation on the Shear Strength and Capacity of Concrete Block Masonry
Partially grouted concrete masonry shear walls are widely used because they provide a balance between structural performance and construction efficiency. However, the effects of material properties, grouting, and reinforcement on their shear resistance are not fully understood, and existing design …
-
Concrete block weir and orifice discharge characteristics for stormwater detention outlet control
… outlet control structures constructed of concrete block. The use of such concrete block structures In conjunction with detention storage appears to be growing because of apparent practical, economic, and esthetic advantages over other types of structures. However, lack of published orifice …
-
Evaluation of Mitigative Techniques for Non-Contact Lap Splices in Concrete Block Construction
A previously completed study in the field of concrete block construction by Ahmed and Feldman (2012) indicated that, on average, the reinforcing bars in non-contact lap splices, where the lapped bars are located in adjacent cells, only develop 71% of the tensile resistance of spliced bars which are …
-
Evaluation of contact and non-contact lap splices in concrete block masonry specimens
… and non-contact lap spliced bars in reinforced concrete block masonry using double pullout and wall splice specimens. A total of 32 specimens were tested, consisting of an equal number of double pullout specimens and full-scale wall splice specimens. Both specimen types had the identical …
-
Enhanced Ductility of Masonry Shear Walls Using Laterally Confined (Self-Reinforced) Concrete Block
… method, referred to as Self-Reinforced Concrete Block (SR Block) employs a previously untried technique of molding lateral confining devices into concrete block. This internal reinforcement provides lateral confinement to the enclosed volume of block and grout material. The resulting …
-
ANALYTICAL AND EXPERIMENTAL ASSESSMENT OF REINFORCED CONCRETE BLOCK STRUCTURAL WALLS RESPONSE TO BLAST LOADS
… as threat level, reinforcement ratio, available block width, wall height, and material characteristics. In general, brittle behavior was observed in the walls with a reinforcement ratio higher than 0.6%. This is attributed to the fact that seismically detailed structural masonry walls designed to …
Page 1 of 7