Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 44 for “"Condensation Particle Counter"”
-
Numerical Simulation of Nano-scale to Micro-scale Particle Growth in Condensation Particle Counter
Condensation particle counters are used to measure the concentration of nano-scale particulates in air or gas. A small amount of air/gas is introduced in the particle counter and is mixed with a supersaturated mixture of vapor and a non-condensable gas. Due to the supersaturated conditions, vapor …
-
Evaporation Enhancement for Condensational Nanoparticle Growth in Hydrophobic Evaporation - Condensation Tube
… an alternative method has been utilized. A Condensation Particle Counter (CPC) structure, which benefits from meniscus evaporation of a porous media to make vapor for water droplet growth, has been introduced to analyze the production water droplet. By analyzing the size and concentration of …
-
Monitoring and Measurement of Electronic Nicotine Delivery Systems Using Improved Detection Sensor and Novel Vaping Machine
… capabilities of VM-FRIENDS were combined with a condensation particle counter to enable characterization of vape aerosol production under controlled conditions. This work facilitates further ENDS research by enabling deployment of the FRIENDS sensor in real-world studies and offering VM-FRIENDS …
-
A Lab-based Study for the Generation and Characterization of Particle Emission from Composite Materials Containing Carbon Nanotubes
… to measure and characterize the emission of particles during the sanding of composite materials containing carbon nanotubes (CNTs). The experimental setup consisted of a sand-blasting cabinet with HEPA-filtered air intakes. An electrical motor outside the cabinet was connected to a pulley …
-
Instrument Artifacts Lead to Uncertainties in Parameterizations of Cloud Condensation Nucleation
The concentrations of cloud condensation nuclei (CCN) modulate cloud properties, rainfall location and intensity, and climate forcings. This work assesses uncertainties in CCN measurements and the apparent hygroscopicity parameter (kvapp) which is widely used to represent CCN populations in climate …
-
Atlanta automotive particulate matter exposure and evaluation
… Matter (PM) were made using compact Optical Particle Counters (OPC), a Condensation Particle Counter, and a MicroAethalometer. The time-integrated measurements for Elemental Carbon (EC), Organic Carbon (OC), Water Soluble Organic Carbon (WSOC), particulate elemental concentrations, and …
-
Continued development of a fixed-frequency Albedometer
… sample volume. By comparing optical results to particle concentrations using a condensation particle counter (CPC), we were able to calculate the values of the scattering and extinction cross section (σscat and σext) and compare these to the accepted values calculated from Mie theory. These …
-
Characterization of Scanning Mobility Particle Sizers For Use With Nanoaerosols
… to evaluate the performance of scanning mobility particle sizers in the characterization of nanoaerosols. A sampling chamber was constructed from aluminum and tempered glass, had a volume of 4.6 cubic feet, and was designed for the introduction of aerosols and dilution air, maintenance of aerosol …
-
Atmospheric nucleation : development and application of nanoparticle measurements to assess the roles of ion-induced and neutral processes
… was to enhance our current understanding of new particle formation (NPF) processes in the atmosphere. My contributions include: (1) performing field measurements of atmospheric aerosols and subsequent data analysis of nucleation events, and (2) improving the performance of instruments commonly …
-
Reentrainment of Submicron Solid Particles
… method is developed to study the effects of particle size, flow rate, pulsation, particle/substrate material, and temperature on the short-term reentrainment of submicron particles. The particles tested are in the size range of 10-900 nm and are deposited by wetting the inside of capillary …
-
Evaluation of Ultra Fine Cigarette Smoke Particles Penetration on 3M 6200 Half Mask Respirators with P-100 Filters
… determining the penetration of cigarette smoke particles. In this study, faceseal leakage of a breathing manikin donned a 3M 6200 half mask elastomeric respirator with double P-100 filters was determined at various test conditions. A full factorial test conditions of 4 sealing conditions …
-
Effects of a Manikin on the Capture Efficiency and Protection Efficiency of a Small Rectangular Hood
… of the capture envelope were obtained by particle image velocimetry (PIV) at three orientations (0°, 90°, 180°), with respect to the cross drafts (30, 60, and 120 fpm) generated inside a large wind tunnel. The capturing hood fan speed was set to maintain the Q of nominal Vx values of 50, …
-
A real-world approach to in-vitro lung epithelial cell toxicology of atmospheric air pollutants : from lab to field
… and 2B Technologies Models 714 and 205), and particle sizers and counters covering the inhalable particulate matter size range (fast mobility particle sizer (FMPS, TSI 3091), water condensation particle counter (WCPC, TSI 3789)); all within a mobile setting. With these instruments within the …
-
Molecular and Physicochemical Characterization of Aerosols Relevant to Their Atmospheric Formation and Growth
… composition of nano- to sub-micrometer-sized particles and to obtain kinetic data and physiochemical properties of SOA. The first part of this dissertation describes the development, calibration, and application of Thermal Desorption Chemical Ionization Ion Drift Mass Spectrometry (TD-ID-CIMS) …
-
Miniaturization of Electrical Ultrafine Particle Sizers
Nanoparticles, or ultrafine particles, have potential risks for human health, and the adverse health effects caused by ultrafine particles have been proven to be size related. To meet the increasing demanding for personal exposure monitoring and spatial distribution measurements of ultrafine …
-
ASSESSMENT OF THE RELATIONSHIP BETWEEN OUTDOOR AND INDOOR CONCENTRATIONS OF AIRBORNE PARTICULATES IN RESIDENTIAL BUILDINGS IN SINGAPORE
… comprehensive indoor, outdoor and personal particle characterization study was conducted in a non-smoking apartment for a period of 2 to 10 days during April, 2003 to May, 2003. Concurrent indoor, outdoor and personal particle number measurements were recorded using a handheld condensation …
-
LIGHT ABSORBING AEROSOLS: CALIBRATION, MEASUREMENTS, AND EMISSIONS FOR NEW YORK CITY
… at 300 nm mobility diameter, and then the particle mass, mp, was determined with an aerosol particle mass analyzer (APM). A condensation particle counter (CPC) served as a reference method for measurement of number concentration, Np; when multiplied by mp, Np gives the mass concentration. I …
-
Direct injection gasoline engine particulate emissions
… number concentration and size distribution of particles in the 5-1000 nm size range and b) the factors affecting the PM emissions from spark ignition engines with direct fuel injection. The first objective is achieved by evaluation and comparison of a differential mobility spectrometer; …
-
Penetration, pressure drop, and wickering characteristics of NIOSH certified P-100 and P95 filters under heavy DOP loading.
… is considered as potential health hazards. These particles if ingested/inhaled have long term effects on the health of human beings. The best technique to prevent these harmful particles from reaching the respiratory tract is physical interception. Personal protective equipment such as respiratory …
-
On the spatio-temporal distribution of aerosol particles in the upper troposphere and lowermost stratosphere
… von drei Kondensationspartikelzählern (CPC, Condensation Particle Counter) und einem optischen Partikelgrößenspektrometer (OPSS, Optical Particle Size Spectrometer) verwendet. Zunächst wurde im Labor eine umfangreiche Charakterisierung des IAGOS-CARIBIC OPSS hinsichtlich der Zähleffizienz …
Page 1 of 3