Results 1 to 8 of 8 for “"Condensing heat exchanger"”
-
Process-Level Investigation of the Flue Gas Latent Heat Recovery Using a Condensing Heat Exchanger in a Biomass-Fired Boiler
… the energy used for evaporation as latent heat. Unrecovered latent heat ultimately decreases the overall boiler efficiency. One way to recover a portion of this latent heat is to cool the flue gas below its dew point temperature using a condensing heat exchanger (CHE). This study develops a …
-
Economic analysis of water recovery from flue gas: A South African case study
… Eskom’s Medupi Power Station as a case study; condensing heat exchanger technology, desiccant drying systems and membrane technology using membrane modules developed by other students in this project. The water vapour selective membrane technology turned out to be superior.
-
Low temperature heat and water recovery from supercritical coal plant flue gas
… original thermodynamic model to estimate waste heat and water recovery from the flue gas of a supercritical coal plant burning lignite, subbituminous, or bittuminous coal. This model was written in MATLAB as a list of linear equations based on first and second law analyses of the power plant …
-
A Closed-Loop, Forced-Convection Drying Process For Water Recovery And Microbial Stabilization Of Astronaut Cabin Waste
… are solved by a closed-loop, forced-convection, heat-pump drying system which stops microbial activity by both pasteurization and desiccation, and recovers moisture in a gravity-independent porous media condensing heat exchanger (PMCHX). Detailed transport models were developed for the two major …
-
Prediction and control of frost formation in an air to air heat exchanger
Air-to-air heat exchangers can be used to preheat ventilating air and hence increase the winter ventilation rate in livestock barns; however, frost accumulation is a major problem in this application. Currently available frost control systems operate based on some combination of time, core pressure …
-
Visualization of dropwise condensation on vertical plate and horizontal tube geometry
… dropwise condensation. Dropwise condensation heat transfer may be modeled by combining an expression for the single droplet heat transfer rate with the droplet size distribution. The ability to measure this distribution is integral to the validation of such models. An example study is …
-
Evaluation of Grundfos CRE 15-3 Variable Speed Centrifugal Pump and Worthington Constant Speed Centrifugal Pump Applications in KU Steam Power Plant
… is the deaerator tank, whose function is to preheat and deaerate the condensate water, before it is supplied to the boiler. This deareator tank is located in the basement of the steam power plant. The second component is the vent condensing heat exchanger, which is located on the first floor of …