Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 2,003 for “"Conduits"”

  1. Lubricity of biomedical conduits

    … quantify them. Despite the fact that biomedical conduits are routinely made lubricious by a host of different methods, there is an insufficiency in the present state of knowledge with regard to how to precisely quantify conduit bore lubricity. Test methods, newly invented, to characterize tubing …

    umn Repository record for Lubricity of biomedical conduits (opens in a new tab)

  2. Biokompatibilitätsuntersuchung von Conduits für den Pulmonalklappenersatz

    … rechtsventrikulären Ausflusstrakt explantierten Conduits die zelluläre und extrazelluläre Gewebereaktion auf die Implantate untersucht. Die histopathologische Auswertung der Homografts, Rindervenengrafts und Hancock- bzw. PTFE-Conduits erfolgte nach einem einheitlichen Protokoll unter Einsatz …

    goettingen Repository record for Biokompatibilitätsuntersuchung von Conduits für den Pulmonalklappenersatz (opens in a new tab)

  3. Pipe fractional flow through branched conduits

    In the field of multiphase flow, the so-called phase splitting problem is a recurrent topic of discussion. In a branching conduit, it is of practical importance to know a priori how the phases split. Over the years, a variety of models have been developed to predict this and describe the physics …

    texas Repository record for Pipe fractional flow through branched conduits (opens in a new tab)

  4. Polymeric Nanofiber Conduits for Peripheral Nerve Regeneration

    Synthetic polymer nanofiber conduit was fabricated to act as a guiding construct for peripheral nerve gap repair. The conduit consisted of two layers of nanofiber membranes - inner layer of aligned nanofibers to guide axon outgrowth; outer layer of randomly arranged nanofibers to provide mechanical …

    nus Repository record for Polymeric Nanofiber Conduits for Peripheral Nerve Regeneration (opens in a new tab)

  5. Thermomechanical milling of lithics in volcanic conduits

    Pyroclastic deposits resulting from explosive volcanic eruptions commonly contain clasts originating from the conduit wall rocks, which were entrained into the rapidly ascending stream of erupting material. These particles are termed accessory lithic clasts. Previous studies of the relative …

    ubc Repository record for Thermomechanical milling of lithics in volcanic conduits (opens in a new tab)

  6. Air Demand in Free Flowing Gated Conduits

    A physical experimental setup of a circular, gated closed conduit was built at the Utah Water Research Laboratory (UWRL). Setup configurations were modified and data were measured to aid in the study of physical variables on air demand. It was determined that gate opening, gate and water surface …

    utahstate Repository record for Air Demand in Free Flowing Gated Conduits (opens in a new tab)

  7. Modeling of hydraulic transients in closed conduits

    Hydraulic transients (often known as 'water hammer') occur as a direct result of rapid variations in the flow field in pressurized (closed-conduit) systems. For example, changes in velocity from valve closures or pump operations cause pressure surges that are propagated away from the source …

    colostate Repository record for Modeling of hydraulic transients in closed conduits (opens in a new tab)

  8. Fissures and fountains: magma dynamics in basaltic conduits

    Basaltic volcanoes are responsible for the bulk of the planet’s magma output. Their eruptions are often spectacular and can have serious impacts on a local scale (through lava flows) and regional scale (through emission of ash and toxic gases). However, hazard planning and mitigation is challenging …

    durham Repository record for Fissures and fountains: magma dynamics in basaltic conduits (opens in a new tab)

  9. REPEATED BIPHASIC CONDUCTING CONDUITS FOR PERIPHERAL NERVE REPAIR

    Each year 400,000 Americans sustain nerve transection injuries which require surgical intervention for repair. Due to rapid scar formation which blocks nerve outgrowth, there are no treatment options for the approximately 90% of patients who have gaps greater than 3 cm. Resultantly, researchers …

    wfu Repository record for REPEATED BIPHASIC CONDUCTING CONDUITS FOR PERIPHERAL NERVE REPAIR (opens in a new tab)

  10. Mixing in axisymmetric gravity currents and volcanic conduits

    … as occurs in the near surface region of volcanic conduits connected to surface lava lakes. We derive a theoretical model to estimate the heat flux associated with such a system using the empirical law for the dispersive mixing. The predicted heat flux associated with the bubbles is found to be …

    cambridge Repository record for Mixing in axisymmetric gravity currents and volcanic conduits (opens in a new tab)

  11. An equivalent orifice for short conduits in SWMM5+

    Model time steps in the US EPA Storm Water Management Model (EPA SWMM) are typically controlled by the shortest links in the network. This problem is exacerbated in the finite-volume SWMM5+ hydraulic solver due to the need to provide at least three computational elements in each link. In EPA SWMM, …

    texas Repository record for An equivalent orifice for short conduits in SWMM5+ (opens in a new tab)

  12. Modeling particulate flows in conduits and porous media

    Particulate flows exist in a wide range of engineering applications such as drilling and completion operations—from hole-cleaning to well stimulation to sand control. The operations involving particulate flows typically focus on achieving either (1) efficient particle transport or (2) effective …

    texas Repository record for Modeling particulate flows in conduits and porous media (opens in a new tab)

  13. Multiphysics Topology Optimization of Small-Scale Hydraulic Conduits

    This dissertation focuses on the application of thermal-fluid-structure topology optimization to small-scale hydraulic systems for robotic exoskeletons. The primary goal was to develop optimization capabilities that can simultaneously consider fluid flow, heat transfer, and structural integrity …

    umn Repository record for Multiphysics Topology Optimization of Small-Scale Hydraulic Conduits (opens in a new tab)

  14. Some aspects of stratified flow in closed conduits

    … of stratified flow were conducted in closed conduits, which included, l. numerical solution of velocity distribution by using a digital computer, 2. analytical solution and experimental verification of the internal surge wave velocity, 3. experimental observation on the mutual intrusion …

    vt Repository record for Some aspects of stratified flow in closed conduits (opens in a new tab)

  15. Exploring fast drying and evaporation from nanofluidic conduits

    Drying and evaporation from nanoscale conduits are two ubiquitous phenomena found in nature. As these two nanoscale liquid-vapor phase change phenomena are significantly “accelerated” compared with the corresponding ones at micro- and macro-scales, various industrial applications, including oil …

    bu Repository record for Exploring fast drying and evaporation from nanofluidic conduits (opens in a new tab)

  16. Advanced Manufacturing of Microfiber Conduits for Tissue Engineering

    This thesis investigates the application of high-resolution additive manufacturing, specifically melt electrowriting (MEW), for the fabrication of bioengineered scaffolds designed for tissue engineering (TE). The research spans the scientific, technological, and translational dimensions of MEW, …

    oregon Repository record for Advanced Manufacturing of Microfiber Conduits for Tissue Engineering (opens in a new tab)

  17. Analysis and stability of large-span flexible conduits

    Thesis (Ph. D.)--Michigan State University. Department of Civil and Sanitary Engineering, 1982

    msu Repository record for Analysis and stability of large-span flexible conduits (opens in a new tab)

Page 1 of 101