Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 585 for “"Cone Beam computed tomography"”
-
Statistical Image Analysis in Cone-beam Computed Tomography
Cone-beam computed tomography (CBCT) is used to verify the patient’s position prior to commencing radiotherapy treatment. Soft tissues such as the prostate are hard to distinguish, and so gold markers may be implanted. These markers cause artefacts in the 3D reconstruction.In this thesis, we apply …
-
Cone-Beam Computed Tomography For Neuro-Angiographic Imaging
… small footprint, and adaptable geometry, cone-beam computed tomography (CBCT) systems have shown to be valuable for point of care applications that require timely diagnosis. However, image quality in CBCT scanners are potentially limited by slow rotation speed and are therefore challenged …
-
Cone-Beam Computed Tomography and Orthodontics: Awareness Assessment
… community's knowledge and understanding of Cone-Beam Computed Tomography (CBCT) technology as well as awareness of the implications of CBCT use, including risk assessment, radiation dose estimation, diagnostic utility, and issues of informed consent. It is incumbent on the profession to …
-
Efficacy of cone beam computed tomography use in endodontics
IINTRODUCTION: This study’s aims were to: 1) evaluate whether or not there was a treat- ment plan change, if CBCT is used; and 2) evaluate if the use of CBCT as diagnostic tool improves the treatment outcome. We hypothesized that 1. the use of CBCT as diagnostic tool changes the treatment plan; and …
-
Geometrical Calibration and Filter Optimization for Cone-Beam Computed Tomography
… the requirements of a software library for tomography and will derive a framework which can be used to realize various applications in cone-beam computed tomography (CBCT). The presented framework is self-contained and is realized using the MATLAB environment in combination with native …
-
Cone Beam Computed Tomography - radiation dose and image quality assessments
… technologies are available to the dental field, cone beam computed tomography (CBCT) as one of the most important. CBCT is a catch-all term for a technology comprising a variety of machines differing in many respects: patient positioning, volume size (FOV), radiation quality, image capturing and …
-
The Clinical Applications of Cone Beam Computed Tomography in Endodontics
… of 5 investigations assessed the application of cone beam computed tomography (CBCT) for the management of endodontic problems. Cone beam computed tomography improved the detection of the presence and absence of simulated periapical lesions in human dry mandibles. The overall sensitivity was …
-
Deep Autofocus for Motion Compensation in Cone-Beam Computed Tomography
Cone-beam computed tomography (CBCT) is increasingly used in interventional radiology, providing 3D imaging for procedure planning, guidance, and outcome assessment. In neuroradiology, CBCT is a critical tool for various applications, including brain perfusion, radiotherapy, and stroke diagnosis. …
-
Applications of cone beam computed tomography in radiotherapy treatment planning.
… capable of 2D planar imaging, fluoroscopy and 3D Cone Beam Computed Tomography (CBCT) imaging. With CBCT imaging, the treatment plan can be modified based on patient’s anatomy just before the treatment session. This method of Adaptive Radiotherapy (ART) helps in managing a patient’s treatment by …
-
Investigation of Imaging Capabilities for Dual Cone-Beam Computed Tomography
<p>A bench-top dual cone-beam computed tomography (CBCT) system was developed consisting of two orthogonally placed 40x30 cm<super>2</super> flat-panel detectors and two conventional X-ray tubes with two individual high-voltage generators sharing the same rotational axis. The X-ray source to …
-
Effect of Scanning Conditions on Cone Beam Computed Tomography Gray Value
Cone beam computed tomography (CBCT) produces a three-dimensional image that allows for precise diagnosis and better treatment planning of various dental complications. However, reliability of CBCT to measure bone mineral density (BMD) measurement has not fully evaluated. Thus, the objective of the …
-
Iterative Reconstruction Technique for Cone-beam Computed Tomography with Limited Data
X-ray cone-beam computed tomography (CBCT) has been extensively used in various applications, especially in medical analysis and the image-guided radiation therapy (IGRT). There have been on-going attempts to reconstruct images using a reduced number of projection data, in order to reduce the …
-
X-ray Scatter Computation and Simulation in Cone Beam Computed Tomography
In cone beam computed tomography (CBCT) with a large subject volume within the x-ray field, the measured signal can be contaminated by a large amount of scattered photons due to x-ray interactions with the irradiated object. The photon scatter can severely degrade the quality of the reconstructed …
-
Algorithms for Quantitative Imaging with Advanced Cone-Beam Computed Tomography Configurations
Cone-Beam Computed Tomography (CBCT) is an emerging technology that offers several potential advantages over conventional multi-detector CT, including superior spatial resolution, point-of-care accessibility, and flexible mechanical designs enabling application-specific scanner configurations. When …
-
Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy
Kilovoltage cone-beam computed tomography (kV CBCT) has important applications in image guided radiation therapy (IGRT). In its current state, CBCT is suboptimal for these applications due to its considerable radiation dose, poor soft-tissue contrast and inaccurate Hounsfield Units as a result of …
-
A Digitized Comparison using Cone Beam Computed Tomography and Intraoral Scanning
… a missing tooth in area #19 were examined. Cone beam computed tomography .STL files were used as the first test group. Intraoral scans were used as the second test group. Desktop scans of each model and the .STL file was used as a control. The .STL files were then superimposed onto each …
-
CONE BEAM COMPUTED TOMOGRAPHY (CBCT) DOSIMETRY: MEASUREMENTS AND MONTE CARLO SIMULATIONS
<p>Cone beam computed tomography (CBCT) is a 3D x-ray imaging technique in which the x-ray beam is transmitted to an object with wide beam geometry producing a 2D image per projection. Due to its faster image acquisition time, wide coverage length per scan, and fewer motion artifacts, the CBCT …
-
CONE-BEAM COMPUTED TOMOGRAPHY (CBCT) SEGMENTATION BY ADVERSARIAL LEARNING DOMAIN ADAPTATION
Cone-beam computed tomography (CBCT) is increasingly used in radiotherapy for patient alignment and adaptive therapy where organ segmentation and target delineation are often required. However, due to the poor image quality, low soft tissue contrast, as well as the difficulty in acquiring …
Page 1 of 30