Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 6 of 6 for “"Cone-plate viscometer"”.
-
Μορφοποίηση και μελέτη κολλοειδών διαπορών (μικρογαλακτώματα - γέλες - γαλακτώματα) για καλλυντική χρήση
… of microemulsion gels was measured by means of cone-plate viscometer, whereas that of microemulsions and emulsions by Ubbelohde viscometers. Microemulsion gels performed a pseudoplastic behavior and on the other hand emulsions and microemulsions a newtonian one. Emulsion stability was tested by …
-
Estudos reológicos de cimentos asfálticos
… tests on asphalt cement samples using cone-plate viscometer and dynamic mechanical thermal analyser; comparison with properties of a standard sample, derived from Venezuelan crude; and correlation with mechanical properties. The weathering effect is compared to the ageing in-situ, …
-
Rheology, phase morphology and processing of polymer blends
… static mixer system, (b) samples removed from a cone-plate viscometer, (c) extrudates from capillary dies, (d) melt spun fibers, and (d) biaxially stretched films. Disperse phase dimensions were measured. The values varied from 1-5μ in the products from static mixers. The dimensions of the …
-
Comparative Evaluation of the Performance of Synthetic Polymer and Biopolymer as a Means of Enhanced Oil Recovery Method
… For rheological studies of both polymers, a cone/plate viscometer was introduced to investigate the apparent viscosity of polymer solutions over varying influential factors at various shear rates. The findings show that the biopolymer solution demonstrated a much larger viscosity loss …
-
A Bench Top Study Of The Optimization Of Lvad Cannula Implantation To Reduce Risk Of Cerebral Embolism
… match blood viscosity measured with a rotating cone-plate viscometer. The Reynolds number in the ascending aorta is matched in the flow model. A closed loop mock circulatory system is then realized. In order to match the Reynolds number in the ascending aorta and LVAD cannula with that of the …
-
The effect of fluid shear stress on growth plate chondrocytes
… be affected by mechanical forces. The growth plate is a small layer of cartilage that functions to facilitate longitudinal growth of the long bones from in utero through post-adolescent development. The growth plate maintains distinct regions of chondrocytes at carefully regulated stages of …