Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 44 for “"Connection behavior"”
-
Two novel techniques to study multiple bolted wood connection behavior
… were evaluated for studying multiple-bolted wood connection behavior. The instrumented shear bolts output an electronic signal proportional to the shear forces transmitted through the bolt in a double-shear connection during loading. The digital image correlation method combines digital image …
-
Screw-Fastened Cold-Formed Steel-to-Steel Shear Connection Behavior and Models
… single-fastened cold-formed steel-to-steel shear connections. Predictions are validated through an experimental study considering ply configuration and a single Hex #10 -washer head fastener, centered in a 102 mm by 102 mm three boundary window. The fastener tilting angle is captured using an …
-
The Connection Behavior of Precast Prestressed Piles to Cast-In-Place Bent Caps
The state of South Carolina employs a unique connection detail between precast prestressed piles to cast in place bent caps. This detail is constructed by plainly embedding piles to a specified depth into bent caps. Typically in regions of high seismicity such as South Carolina connections between …
-
Initial Investigation of Connection Behavior for Buckling-Restrained Braces (BRBs) in Precast Concrete Frames
… an extensive review of potential brace-to-frame connection designs for precast BRBFs and to experimentally test a connection design through representative seismic loads. To complete the first objective many potential connection designs were examined, including some that had the advantage of …
-
Finite Element Analysis of the Connection Behavior of Precast Prestressed Piles to Cast-In-Place Bent Caps
… perform a parametric study used to determine the connection behavior of precast prestressed pile to cast in place bent caps for various pile sizes and bent cap embedment depths. Current construction practice in South Carolina involves a plain pile embedment to a depth equal to a single pile …
-
Analysis of the effect of hysteretic relationships in beam-column connections on the earthquake response of precast reinforced concrete frame systems
… and other factors, exhibit diverse hysteretic behaviors when subjected to strong lateral forces. This study examines the effect that different hysteretic models for beam-column connections have on the behavior of a 5-story and a 15-story precast reinforced concrete frame building subjected to …
-
Seismic Design Studies of Low-Rise Steel Frames
In this investigation, the inelastic behavior of low-rise buildings with steel moment-resisting frames providing the lateral resistance for strong ground motions was examined. The inelastic behavior of frames is dependent on several parameters such as design base shear, beam-to-column strength …
-
Vulnerability assessment of extended end-plate connections under mainshock-aftershock sequences
… seismic events in the mid 90s where welded connections performed poorly, bolted beam-to-column connections were investigated as a potential alternative. Extensive experimentation was performed to better understand the behavior of the joints, and models were developed in order to simulate …
-
Effect of strain softening on the ultimate strength and stability of flexible frames.
The principal role of any structural connection is to transfer forces safely between the various components meeting at that joint. Therefore, it is important for these connections to provide adequate structural strength to resist the loads and possess the necessary ductility to deform as the …
-
Development of a Phenomenological Model For Beam–to–Column Connections in Moment Resisting Frames Subjected to Seismic Loads
… January 17, 1994 based on the premise that these connections are fully rigid and stiff enough to transfer any magnitude of seismic loads. But, the wide range brittle fracture failures of beam–to–column connections in WSMF proved that the idealization of these connections as fully rigid need to be …
-
A contribution to the computer aided design of optimized structures for the steel industry
… method of incorporating realistic flexible connections including the effect of connection sizes and shear deflection in plane frame analysis is presented. The general algorithm can be easily implemented in a standard plane frame analysis program and once implemented it can be an ideal tool …
-
Investigation of the effects of dynamic loads on reinforced concrete flat-plate buildings under collapse scenarios
… on the floors below. Furthermore, while the behavior of RC members under static and high-rate (blast) loads are well researched, there is less information about the response under medium rate loads that occur during collapse. This research first looks specifically at flat-plate slab column …
-
Cyclic Behavior of a Hybrid Light Gauge and HSS Mezzanine Structural System
… limited experimental data outlining the behavior of these structures is available and design criteria is very limited. Thus, there is a need to conduct reliable experimental tests to understand fundamental behavioral mechanisms for migration into effective design criteria. A full analysis …
-
Design of frames with partially restrained connections.
… consider the partial restraint (PR) in a steel connection. The success of efforts to include connection effects in the design will depend greatly on the development of reliable and practical analytical methods for the prediction of connection behavior. The moment-rotation relationships for 31 …
-
Experimental Investigation of Group Action Factor for Bolted Wood Connections
… yield and capacity of single-shear bolted wood connections loaded parallel to grain. The single and multiple-bolt connections tested represent common connection geometries used in wood construction in the United States. The results of both monotonic and cyclic loading of connections are …
-
Double Angle Framing Connections Subjected to Shear and Tension
The double angle connection (sometimes referred to as a cleat connection) is one of the most commonly used simple shear connections, and many investigations have been conducted on this type of connection. However, most of these investigations have focused on either the strength or the …
-
Behavior of Prestressed Pile to Bent Cap Connections and Damage Evaluation with Acoustic Emission
The state of South Carolina employs a unique connection detail between precast prestressed piles to cast in place bent caps. This detail is constructed by plainly embedding piles to a specified depth into bent caps. Typically in regions of high seismicity such as South Carolina connections between …
-
Cyclic Testing of Special Moment Frame Connections With Buckling-Restrained Fuse Plates
… evaluation of a new special steel moment frame connection that employs replaceable buckling-restrained fuse plates that can enhance seismic performance and post-earthquake repairability. A total of eight unique specimens were tested on two series of beam-to-column subassemblies (W36 and W24) to …
-
Elastic Rotational Stiffness of an Embedded Steel Plate-Timber Connection A Simplified Solution, Based on an Analytical Study Verified by Numerical Modeling
Connections are among the most complex elements to analyze and design within struc tural engineering. They consist of multiple interacting components, involve intricate load-transfer mechanisms, and exhibit nonlinear behavior that is difficult to capture us ing simple assumptions. Although …
-
The Effects of Bolt Spacing on the Performance of Single-Shear Timber Connections Under Reverse-Cyclic Loading
… raised interest in the response of structural connections to dynamic loads. This increased interest led the Consortium of Universities for Research in Earthquake Engineering (CUREE) to develop a testing protocol for reverse-cyclic loading, which involves cycling loads through zero in order to …
Page 1 of 3