Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"Connection response"”.

  1. Development and assessment of response and strength models for bolted steel connections using refined nonlinear 3D finite element analysis

    The difficulty in developing bolted connection designs lies in the limitations in existing methods to characterize their strength and typically nonlinear response due to the complex interaction of the bolts and structural components. Yet it is necessary for the engineer to be able to determine the …

    gatech Repository record for Development and assessment of response and strength models for bolted steel connections using refined nonlinear 3D finite element analysis (opens in a new tab)

  2. The influence of semi-rigid connections on the performance of steel framed structures in fire.

    … LBTF have suggested that even nominally `simple' connections are capable of providing significant restraint at elevated-temperatures. As most frames are designed assuming pinned response at ambient-temperature, with no account being taken of the reduction in mid-span moments, this is an aspect of …

    whiterose Download PDF for The influence of semi-rigid connections on the performance of steel framed structures in fire. (opens in a new tab)

  3. Robustness of Steel Connections Loaded at High Rates

    … through the remaining structure. For this reason connections are important in enabling the structure to bridge over the lost column. Connections also need to be capable of resisting high strain rates arising from the dynamic redistribution of moments and tension loads which means they require high …

    whiterose Download PDF for Robustness of Steel Connections Loaded at High Rates (opens in a new tab)

  4. Capacity Resistance and Performance of Single-Shear Bolted and Nailed Connections: An Experimental Investigation

    … the behavior of single-shear, laterally-loaded connections when loaded up to and beyond capacity (i.e., maximum resistance). Specimens included a wide array of connection configurations common in wood construction. All connections were tested monotonically in tension under …

    vt Repository record for Capacity Resistance and Performance of Single-Shear Bolted and Nailed Connections: An Experimental Investigation (opens in a new tab)

  5. The Abaqus/CAE Plug-in for Premium Threaded connection 3D parameter Finite Element Model

    … Analysis (FEA) is proposed to simulate the connection response of practical in-service conditions and test the performance of Oil Country Tubular Goods (OCTG) premium threaded connections. A plug-in is developed in Abaqus/CAE for creating the 360-degree full 3D parametric finite element …

    vt Repository record for The Abaqus/CAE Plug-in for Premium Threaded connection 3D parameter Finite Element Model (opens in a new tab)

  6. Computational Finite Element Analysis Of Extreme Loading Response Of Structural Insulated Panel (Sip) Building Subsystems

    … and FMS Engineering, LLC, Mobile, Alabama. The connections between the sip panels, including a cam-locking device comto sip panel construction, were identified as vulnerable under high velocity wind loads. At that time, there were no published guidelines for performing a computational finite …

    mississippi Repository record for Computational Finite Element Analysis Of Extreme Loading Response Of Structural Insulated Panel (Sip) Building Subsystems (opens in a new tab)

  7. Characterization of polymer-fiber composite sheet retrofits for blast mitigation

    … analysis methodology for predicting the dynamic response of a PFCS and CMU wall system. Therefore, the engineering properties of the composite sheets, the connection details, and a preliminary static resistance function for the PFCS are evaluated experimentally in this thesis. The research has …

    missouri Repository record for Characterization of polymer-fiber composite sheet retrofits for blast mitigation (opens in a new tab)

  8. A framework for fire performance assessment of mass timber structures : numerical and machine-learning approaches

    … exposure. A component-based glulam beam-column connection model is proposed using nonlinear springs to represent the responses of shear planes, simplifying the modelling procedure and improves the computational efficiency. A multi-fidelity neural network (MFNN) is then introduced to integrate …

    ubc Repository record for A framework for fire performance assessment of mass timber structures : numerical and machine-learning approaches (opens in a new tab) Download PDF for A framework for fire performance assessment of mass timber structures : numerical and machine-learning approaches (opens in a new tab)

  9. The behaviour of steel and composite beam-to-column connections in fire.

    … real fires have demonstrated the significance of connections in fire, when they can have beneficial effects on the survival time of the structure. The lack of experimental data on the behaviour of steel and composite connections in fire means that this is insufficiently addressed in current design …

    whiterose Download PDF for The behaviour of steel and composite beam-to-column connections in fire. (opens in a new tab)

  10. Design of moment end-plate connections for seismic loading

    … and experimental research into the seismic response of four-bolt extended moment end-plate connections was conducted. Full-scale connections, ranging in size from moderate to large, were designed, fabricated and tested under cyclic loading until connection failure was observed. The design …

    vt Repository record for Design of moment end-plate connections for seismic loading (opens in a new tab)

  11. Seismic Behaviour of Grouted Connections in Precast Concrete Panels

    … a considerable number of precast concrete panel connection failures. This observation prompted a review of more than 4700 panel details to establish representative details used in both existing and new multi-storey and low rise industrial precast concrete buildings. The detailing and quantity of …

    auckland-ms Repository record for Seismic Behaviour of Grouted Connections in Precast Concrete Panels (opens in a new tab)

  12. Behaviour of Blind Bolted Moment Connections for Square HSS Columns

    … of a simple and practical field-bolted moment connection between a W-shape beam and an HSS column.</p> <p>The objectives of this research study are to develop a practical bolted moment connection between a W-shape beam and a square HSS column and to evaluate its behaviour experimentally under …

    mcmaster Repository record for Behaviour of Blind Bolted Moment Connections for Square HSS Columns (opens in a new tab)

  13. Wind load sharing and vertical load transfer from roof to wall in a timber-framed house

    … and that failures take place at inter component connections; hence there is a need to study the load sharing and structural response of these timber-framed house structural systems to assess their performance. Contemporary houses in many parts of Australia are brick veneer structures with metal …

    jamescook Download PDF for Wind load sharing and vertical load transfer from roof to wall in a timber-framed house (opens in a new tab)

  14. On the Seismic Performance of Skewed Special Moment Frame Reduced Beam Section Connections

    … features. Reduced beam section (RBS) connections are popular SMF connection details developed following the Northridge earthquake to limit brittle fractures within connection welds. Current American Institute of Steel Construction (ASIC) provisions (i.e. AISC 341-16) provide …

    arkansas Repository record for On the Seismic Performance of Skewed Special Moment Frame Reduced Beam Section Connections (opens in a new tab)

  15. Fire behaviour of blind-bolted connections to concrete filled tubular columns under tension

    … the designers. Nonetheless, how to solve the connection with I-beams is still a handicap and requires a specific study. One of the most common and popular solution to connect open section steel beams (I-beams) to open section steel columns are endplate connections. In the cases of columns with …

    upv Repository record for Fire behaviour of blind-bolted connections to concrete filled tubular columns under tension (opens in a new tab)

  16. Steel fracture modeling at elevated temperature for structural-fire engineering analysis

    … to accurately predict thermal and structural response to fire. For steel structures, significant advances have been made in using finite element models for predicting the response of members, connections and entire structural systems exposed to fire. However, predicting the initiation and …

    texas Repository record for Steel fracture modeling at elevated temperature for structural-fire engineering analysis (opens in a new tab)

  17. The behaviour of steel fin plate connections in fire

    … frames by taking advantage of realistic connection moment-rotation response. This has necessitated the development of an effective and practicable methodology to describe steel connection behaviour, despite its inherent complexity. Although, the evaluation of steel connections' …

    whiterose Download PDF for The behaviour of steel fin plate connections in fire (opens in a new tab)