Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 247 for “"Constant Power"”.

  1. Hierarchical control of dc microgrids with constant power loads

    … control schemes for dc microgrids loaded by constant power loads (CPLs). CPLs form a major proportion of the system loads in many microgrids. Without proper control, CPLs present destabilizing effect at the dc microgrid. In addition to stable operation of microgrid, proper current sharing …

    texas Repository record for Hierarchical control of dc microgrids with constant power loads (opens in a new tab)

  2. Analysis and control of power converters with instantaneous constant-power loads

    … examines the effects of instantaneous constant-power loads (CPLs) on power converters. These CPLs are prevalent in distributed power architectures and are also present in certain motor-drive applications. CPLs introduce a destabilizing nonlinear effect on power converters through an …

    texas Repository record for Analysis and control of power converters with instantaneous constant-power loads (opens in a new tab)

  3. Modeling and analysis of a constant power series-loaded resonant converter

    … systems and ships are being designed with pulse-power loads and hybrid electrical systems. There is a demand for efficient, reliable, and durable compact power converters to bridge pulse-power systems with the electrical plants of the future. This thesis presents modeling and analysis of a …

    nps Repository record for Modeling and analysis of a constant power series-loaded resonant converter (opens in a new tab)

  4. Electric vehicle power trains : high-performance control for constant power load stabilization

    … vehicles around the world. The complex powering structure of automotive electric systems can be described as a distributed multiconverter architecture. In pursuit of performance, constant-power behavior of tightly regulated downstream converters has raised as an important challenge in …

    ubc Repository record for Electric vehicle power trains : high-performance control for constant power load stabilization (opens in a new tab) Download PDF for Electric vehicle power trains : high-performance control for constant power load stabilization (opens in a new tab)

  5. Active adaptive auxiliary circuit for stabilizing dc distribution systems with constant power loads

    The portion of high-bandwidth power converters in modern DC distribution systems has been increasing and is projected to dominate over time. These devices having fast response act as constant power loads (CPLs) and possess the so-called negative incremental input impedance characteristics at the …

    ubc Repository record for Active adaptive auxiliary circuit for stabilizing dc distribution systems with constant power loads (opens in a new tab) Download PDF for Active adaptive auxiliary circuit for stabilizing dc distribution systems with constant power loads (opens in a new tab)

  6. Data-Driven Approach to the Control and Identification of Circuits Containing Constant Power Loads

    Constant Power Loads (CPLs), common in modern electronics, present stability challenges due to their nonlinear behavior, particularly under large disturbances. This thesis investigates the stability boundaries of systems with CPLs and proposes a novel method to expand the estimated Region of …

    buffalo Repository record for Data-Driven Approach to the Control and Identification of Circuits Containing Constant Power Loads (opens in a new tab)

  7. Sliding-mode control of DC–DC boost converter with constant impedance and constant power loads

    … control for boost converters supplying constant impedance and constant power loads. The first part of this thesis reviews the conventional sliding-mode controller for boost converters with simple resistive load and identifies its drawback, whereupon an observer-based fixed-frequency …

    ubc Repository record for Sliding-mode control of DC–DC boost converter with constant impedance and constant power loads (opens in a new tab) Download PDF for Sliding-mode control of DC–DC boost converter with constant impedance and constant power loads (opens in a new tab)

  8. Adaptive active damping methods for DC-AC power-electronic-based systems with constant-power loads

    Many electronic loads in fast-developing power systems behave as constant-power loads (CPLs) which are known to exhibit negative incremental impedance and have a destabilizing effect in the system. To improve the stability of modern power systems with CPLs, research efforts have been focused on …

    ubc Repository record for Adaptive active damping methods for DC-AC power-electronic-based systems with constant-power loads (opens in a new tab) Download PDF for Adaptive active damping methods for DC-AC power-electronic-based systems with constant-power loads (opens in a new tab)

  9. SMALL SIGNAL STABILITY ANALYSIS OF THREE-PHASE MICROGRID SYSTEM IN THE PRESENCE OF CONSTANT POWER LOADS

    … for three-phase microgrid systems with regulated power converters which are used for connecting multiple distributed energy resources (DERs) and in various motor drive applications. The converters behave as constant-power loads (CPLs) and cause instability issues in the system. An impedance-based …

    nus Repository record for SMALL SIGNAL STABILITY ANALYSIS OF THREE-PHASE MICROGRID SYSTEM IN THE PRESENCE OF CONSTANT POWER LOADS (opens in a new tab) Download file for SMALL SIGNAL STABILITY ANALYSIS OF THREE-PHASE MICROGRID SYSTEM IN THE PRESENCE OF CONSTANT POWER LOADS (opens in a new tab)

  10. An adaptive, multi-rate linear quadratic regulator for a shipboard MVDC distribution system with constant power loads

    … will include multiple layers of electronic power converters. When coupled to high-bandwidth controllers, power converters behave as constant power loads to the distribution system. Constant power loads have a negative non-linear impedance characteristic that threatens system stability. Many …

    nps Repository record for An adaptive, multi-rate linear quadratic regulator for a shipboard MVDC distribution system with constant power loads (opens in a new tab)

  11. Stability Analysis of a Constant Power Load Serviced by a Buck Converter as the Source Impedance Varies

    … current (DC)-DC and DC-alternating current (AC) power converters and understanding how to solve the issues that come with using them, are very important. The negative input impedance that is observed when using a buck converter servicing a constant power load (CPL) is one of the issues that needs …

    nps Repository record for Stability Analysis of a Constant Power Load Serviced by a Buck Converter as the Source Impedance Varies (opens in a new tab)

  12. Cardiovascular Responses of Trained Cyclists to Different Pedaling Rates at a Constant Power Output on a Cycle Ergometer

    … of the three trials for which work rate was kept constant with varying pedal rate and resistance. Variables included oxygen uptake, cardiac output, heart rate, stroke volume, arterio-venous O2 difference, respiratory exchange ratio, and respiratory rate. Basic descriptive statistics (mean, …

    eiu Repository record for Cardiovascular Responses of Trained Cyclists to Different Pedaling Rates at a Constant Power Output on a Cycle Ergometer (opens in a new tab)

  13. Analysis of extended Constant Power Speed Range of the Permanent Magnet Synchronous Machine driven by Dual Mode Inverter Control

    … Magnet Synchronous Machine (PMSM) operating at Constant Power Speed Range (CPSR). The proposed technique to drive the PMSM at CPSR is the Dual Mode Inverter Control (DMIC) The mam idea behind DMIC is to change the three-phase operation of the PMSM below base speed to hybrid, single-phase and …

    utk-theses Repository record for Analysis of extended Constant Power Speed Range of the Permanent Magnet Synchronous Machine driven by Dual Mode Inverter Control (opens in a new tab)

  14. The effect of cadence on aerobic and anaerobic contributions to the total energy requirements of cycling at constant power output

    Steady-state cycling at constant power output can be achieved at any one of a number of cadences. Data have been published (Coast and Welch, 1985) that suggest riding at a particular cadence which minimizes oxygen uptake (VO₂) aids in achieving optimal performance. This cadence has been referred to …

    ubc Repository record for The effect of cadence on aerobic and anaerobic contributions to the total energy requirements of cycling at constant power output (opens in a new tab) Download PDF for The effect of cadence on aerobic and anaerobic contributions to the total energy requirements of cycling at constant power output (opens in a new tab)

  15. State Space Modelling of Current-Mode Control and its Application to Input Impedance Shaping of Power Electronic Constant-Power Loads

    Distributed DC power systems offer many benefits over AC line distribution systems such as improved energy conversion efficiency and reduced mass due to high-frequency isolation. Unfortunately, distributed DC systems with regulated bus voltages suffer from destabilising effects from loading by …

    concordia Download PDF for State Space Modelling of Current-Mode Control and its Application to Input Impedance Shaping of Power Electronic Constant-Power Loads (opens in a new tab)

  16. Reinforcement Learning-Based and Hybrid Control Strategies for Voltage Regulation of DC-DC Converters Supplying Constant Power Loads in DC Microgrids

    … regulation for a DC–DC buck converter supplying Constant Power Loads (CPLs) in DC microgrids. CPLs exhibit negative incremental impedance, often causing oscillations, degraded transient response, and instability, making voltage regulation particularly challenging for conventional control …

    queens Repository record for Reinforcement Learning-Based and Hybrid Control Strategies for Voltage Regulation of DC-DC Converters Supplying Constant Power Loads in DC Microgrids (opens in a new tab)

  17. The development of neuromuscular fatigue throughout constant power output cycling below, at, and above the maximal lactate steady state in young and healthy females and males

    Exercise-induced neuromuscular fatigue development (NMF) is a transient phenomenon in which its etiology, amplitude (i.e., pre- to post-exercise changes) and time course (i.e., changes during the exercise bout) are directly affected by exercise intensity and sex of the population. It has been …

    calgary Repository record for The development of neuromuscular fatigue throughout constant power output cycling below, at, and above the maximal lactate steady state in young and healthy females and males (opens in a new tab)

  18. A smart motor drive system for domestic and industrial applications

    … motor is required to operate in the so-called constant power region. Constant power, when referred to an electrical motor, is characterised by a constant mechanical output power of the motor at any rated torque and speed. The mechanical output power of a motor is the product of its torque and …

    vu-aus Download PDF for A smart motor drive system for domestic and industrial applications (opens in a new tab)

  19. Stability Analysis of Closed Surge Tanks By Phase-Plane Method

    … turbine flow demand are investigated. These are: constant discharge, constant gate opening, constant power and constant power combined with constant gate opening. Singularities of the governing equations are determined and analyzed in each case and stability criteria are developed. For …

    odu Repository record for Stability Analysis of Closed Surge Tanks By Phase-Plane Method (opens in a new tab)

Page 1 of 13