Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 4 of 4 for “"Constant TMP"”.

  1. Membrane selectivity and fouling : insights from advanced characterization techniques

    … run such that the transmembrane pressure (TMP) is fixed, and the permeate flux decreases over time as fouling progresses. However, this change in flux means that the hydrodynamic conditions at the membrane surface are continuously changing, which affects fouling. Industrial filtrations may …

    texas Repository record for Membrane selectivity and fouling : insights from advanced characterization techniques (opens in a new tab)

  2. Investigation into dynamic membranes and integration with anaerobic bioreactors

    … 5g TSS L<sup>-1</sup>), below which changes in TMP could be kept low. Tests were carried out using the two modes of operation: Constant flux and constant pressure (gravity-induced flow). In constant flux operation, the TMP rose significantly when the substrate TSS reached 5 g L<sup>-1</sup>. For …

    soton Download PDF for Investigation into dynamic membranes and integration with anaerobic bioreactors (opens in a new tab)

  3. Optimizing hollow fibre membrane module design in pressurised and submerged ultrafiltration

    … in wastewater. Two mathematical models for constant TMP filtration using dead-end HF membranes were developed using firstly the Darcy friction factor, and secondly, the Hagen–Poiseuille model. The models allowed for the overall theoretical lumen pressure drop values, local flux distributions …

    unsw Repository record for Optimizing hollow fibre membrane module design in pressurised and submerged ultrafiltration (opens in a new tab)

  4. Development of High-throughput Membrane Filtration Techniques for Biological and Environmental Applications

    … HT platform was introduced for multi-modal (constant transmembrane pressure vs. constant flux) testing of flat-sheet membranes used in bio-separations. Furthermore, the first-ever HT modules for parallel testing of HF membranes were developed for rapid fouling tests as well as extended …

    mcmaster Repository record for Development of High-throughput Membrane Filtration Techniques for Biological and Environmental Applications (opens in a new tab)