Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 23 for “"Construct Stiffness"”

  1. In vitro three dimensional biomechanical comparison of two internal fixation methods in equine adult radii

    … 3D relative motion to directly determine construct stiffness was verified. Stiffness results were comparable in magnitude to those theoretically predicted, and were consistently higher than results in the literature due to elimination of potting-fixture-test machine finite stiffness. …

    missouri Repository record for In vitro three dimensional biomechanical comparison of two internal fixation methods in equine adult radii (opens in a new tab)

  2. Significance of the Initial Mechanical Stability for the Fracture Fixation System – A Biomechanical Analysis of Two Generations of Dynamic Compression (DCP) Bone Plate Systems

    … the initial mechanical stability of the fracture construct The purpose of this study was to compare a prototype (OrthoHelix MaxLock<sup>®</sup>) dynamic compression (DCP) bone plate construct to that of an FDA approved DePuy DCP construct with respect to specific parameters and phenomenon …

    ohiolink Repository record for Significance of the Initial Mechanical Stability for the Fracture Fixation System – A Biomechanical Analysis of Two Generations of Dynamic Compression (DCP) Bone Plate Systems (opens in a new tab)

  3. The Effect of Locking Head Inserts on the Biomechanical Properties of a 3.5 mm Broad Locking Compression Plate when used in an Open Fracture Gap Model

    … for fractures in which rigid anatomic reconstruction is not possible. MIPO increases the biomechanical demands on implants through reduced load-sharing between implant and bone. Empty screw holes act as a stress riser and can predispose LCP to premature failure. Locking head inserts (LHI) …

    guelph Repository record for The Effect of Locking Head Inserts on the Biomechanical Properties of a 3.5 mm Broad Locking Compression Plate when used in an Open Fracture Gap Model (opens in a new tab)

  4. <i>In Vitro</i> Biomechanical Comparison of Double Versus Single Plated Tibial Plateau Leveling Osteotomy Constructs in Axial Loading

    … objective of this study was to compare the axial stiffness of TPLO constructs stabilized with a single Synthes® broad TPLO plate (TPLO-broad) or a Slocum TPLO plate and a limited contact dynamic compression plate (LC-DCP) (TPLO-double).</p><p>Synthetic bone models were randomly assigned to one of …

    ohiolink Repository record for <i>In Vitro</i> Biomechanical Comparison of Double Versus Single Plated Tibial Plateau Leveling Osteotomy Constructs in Axial Loading (opens in a new tab)

  5. FUNCTIONAL BIOMECHANICAL EVALUATION OF MULTIPLE DESIGN PROGRESSIONS OF DISTAL RADIUS VOLAR PLATES

    … wrist and digits were applied. The structural stiffness of the construct, stiffness across the created fracture gap and fracture gap micro motion of all the constructs were measured and compared to assess the relative stability of three implants. In the present study, we found that volar fixed …

    ohiolink Repository record for FUNCTIONAL BIOMECHANICAL EVALUATION OF MULTIPLE DESIGN PROGRESSIONS OF DISTAL RADIUS VOLAR PLATES (opens in a new tab)

  6. Biomechanical analysis of femoral fracture fixation using the expert adolescent lateral femoral nail system

    … analysis (FEA) were used to establish the stiffness parameters of small composite femurs with simulated fractures stabilised using ALFN. In comparison to intact femur, construct stiffness ranged from maximum (114%) to minimum (20%) for healed fracture and segmental fracture, respectively. …

    birmingham Repository record for Biomechanical analysis of femoral fracture fixation using the expert adolescent lateral femoral nail system (opens in a new tab)

  7. Anterolateral Versus Medial Plating for Comminuted Intra Articular Distal Tibia Fractures: A Biomechanical Assessment

    … an axial load to the specimen to determine the construct stiffness, followed by a ramp load to failure. An optical tracking system was configured to track the motion of the bone fragments in 3D space. The medial plates tended to provide superior results when compared to the anterolateral plate; …

    mcmaster Repository record for Anterolateral Versus Medial Plating for Comminuted Intra Articular Distal Tibia Fractures: A Biomechanical Assessment (opens in a new tab)

  8. Πειραματική μελέτη της σταθερότητας της ενδομυελικής ήλωσης ασταθών καταγμάτων κνήμης με περιφερικούς κοχλίες διαφορετικού αριθμού και θέσης

    … coronal bending and axial torsion. The passive construct stiffness was measured and statistically analysed with one-way analysis of variance (ANOVA). Although some differences were noted between the stiffness of each group, these were not statistically significant in compression (p=0.105), …

    greece Repository record for Πειραματική μελέτη της σταθερότητας της ενδομυελικής ήλωσης ασταθών καταγμάτων κνήμης με περιφερικούς κοχλίες διαφορετικού αριθμού και θέσης (opens in a new tab)

  9. A Comparison of Dynamic Compression Plates and Locking Compression Plates Using Cantilever Bending in a Canine Ilial Fracture Model

    … were tested in cantilever bending to failure and construct stiffness, yield load, ultimate load at failure, displacement at failure, and mode of failure compared. The mean stiffness (N/mm) of tested DCP constructs was 192 (95% CI 121-264) and of LCP constructs was 224 (95% CI 152 - 295) and mean …

    guelph Repository record for A Comparison of Dynamic Compression Plates and Locking Compression Plates Using Cantilever Bending in a Canine Ilial Fracture Model (opens in a new tab)

  10. Stem cell mobilisation and homing to improve fracture healing

    … mobilisation. Mechanical analysis of the construct stiffness and the interfragmentary strain showed the gap size did not have an influence on the construct stiffness. However, increased gap size significantly reduced day 0 interfragmentary strain (p=0.013), with 1.0mm gap having …

    ucl Repository record for Stem cell mobilisation and homing to improve fracture healing (opens in a new tab)

  11. Influence of Locking Bolt Location on the Mechanical Properties of an Interlocking Nail in the Canine Femur

    … the fatigue properties of an interlocking nail construct are influenced by metaphyseal or diaphyseal location of the locking bolt and to evaluate fatigue properties of locking bolts in metaphyseal and diaphyseal bone under axial and torsional loading. Paired femora from 20 skeletally mature dogs …

    ohiolink Repository record for Influence of Locking Bolt Location on the Mechanical Properties of an Interlocking Nail in the Canine Femur (opens in a new tab)

  12. Optimization of a Novel Nipam-Based Thermoresponsive Copolymer for Intramuscular Injection as a Myoblast Delivery Vehicle to Combat Peripheral Artery Occlusive Disease

    … to their analogous physical properties, such as stiffness, hydrophilicity, & surface energy, that mimic tissue conditions. Polymers having similar mechanical properties to anatomical structures are conducive to cell integration & retention, making polymers an effective biomaterial choice as a …

    calpoly Repository record for Optimization of a Novel Nipam-Based Thermoresponsive Copolymer for Intramuscular Injection as a Myoblast Delivery Vehicle to Combat Peripheral Artery Occlusive Disease (opens in a new tab)

  13. In vivo and mechanical evaluation of Calcium Polyphosphate for bone regeneration in revision total hip replacements

    … had the greatest improvement over MB in terms of construct stiffness, with the particulate composites having the next greatest improvement when pre-compacted. The study confirmed that CPP has potential as a synthetic scaffold for replacing MB in the revision THR procedure.

    ubc Repository record for In vivo and mechanical evaluation of Calcium Polyphosphate for bone regeneration in revision total hip replacements (opens in a new tab)

  14. Effect of the Length of the superficial plate in stacked veterinary cuttable plate constructs: An in vitro study on the bending strength and stiffness, and on the strain distribution

    … on the mechanical properties of a stacked-plate construct made with 2.0-2.7 Veterinary Cuttable platesTM (VCP). Stacking VCP increases construct stiffness compared to using a single VCP but increases stress protection and concentrates stress at the extremities of the implants. We hypothesized …

    guelph Repository record for Effect of the Length of the superficial plate in stacked veterinary cuttable plate constructs: An in vitro study on the bending strength and stiffness, and on the strain distribution (opens in a new tab)

  15. Development of a finite element model of supracondylar fractures stabilized with variable stiffness bone plates

    … intervention. Inadequate fixation device stiffness, which causes unwanted fracture gap motion, is believed to be one of the largest factor in poor healing as it prevents ideal tissue proliferation in the callus. By altering the thickness of orthopaedic bone plates, it was theorized that …

    colostate Repository record for Development of a finite element model of supracondylar fractures stabilized with variable stiffness bone plates (opens in a new tab)

  16. Biomechanical Evaluation of Hybrid Locked Plating for Humeral Shaft Fracture Fixation

    … for fixation of humeral shaft fractures.A hybrid construct with unlocked screws and locked screws has gained popularity forfixation of comminuted fractures. Unlocked screws are used to reduce fracture gap while locked screws with better fixation strength helps maintain and protect the fixation. It …

    ohiolink Repository record for Biomechanical Evaluation of Hybrid Locked Plating for Humeral Shaft Fracture Fixation (opens in a new tab)

  17. Biomechanical Comparison of Wire Circlage and Rigid Plate Fixation for Median Sternotomy Closure in Human Cadaver Specimens

    … of this study was to compare the yield load, construct stiffness, ultimate load, displacement at ultimate load, and post-yield behavior of three sternotomy closure methods (Peristernal wires or Sternalock titanium plates) when stressed in each of three directions: lateral distraction, …

    calpoly Repository record for Biomechanical Comparison of Wire Circlage and Rigid Plate Fixation for Median Sternotomy Closure in Human Cadaver Specimens (opens in a new tab)

  18. Biomechanical Testing of Salter-Harris Fractures Type I and II in the Distal Femur and Proximal Tibia

    … the proximal tibia and distal femur. Rotational stiffness will be used as the primary gauge of efficacy and is tested in flexion and extension, varus and valgus rotation, and internal and external rotation. Comparison of stiffness will be used to determine the optimal fixation method specific to …

    clemson Repository record for Biomechanical Testing of Salter-Harris Fractures Type I and II in the Distal Femur and Proximal Tibia (opens in a new tab)

  19. An in vitro biomechanical study of impaction allografting for revision total hip arthroplasty

    … procedure for the treatment of failed hip reconstructions has shown promising results, but a number of intraoperative and postoperative concerns exist. A fundamental understanding of the biomechanical characteristics of the construct would help in providing surgical guidelines to address the …

    ubc Repository record for An in vitro biomechanical study of impaction allografting for revision total hip arthroplasty (opens in a new tab)

  20. The effect of cage positioning on lumbrosacral vertebral endplate failure in compression

    … fusion cage, a posterior interbody fusion construct was simulated. Specifically, the hypothesis to be tested was that two smaller, posterolaterally positioned interbody cages would provide superior construct stiffness and strength in compression. Nine human cadaver spine specimens from …

    ubc Repository record for The effect of cage positioning on lumbrosacral vertebral endplate failure in compression (opens in a new tab)

Page 1 of 2