Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 90 for “"Contact Method"”.

  1. An Improved Contact Method for Multi-Material Eulerian Hydrocodes

    Realistic and accurate modeling of contact for problems involving large deformations and severe distortions presents a host of computational challenges. Due to their natural description of surfaces, Lagrangian finite element methods are traditionally used for problems involving sliding contact. …

    uab Repository record for An Improved Contact Method for Multi-Material Eulerian Hydrocodes (opens in a new tab)

  2. Non-contact method to assess the surface roughness of metal castings by 3D laser scanning

    <p>This paper defines a methodology to estimate the surface roughness of metal castings by 3D laser scanning. The proposed method applies Principal Component Analysis (PCA) which transforms the point cloud of the casting surface into an orthogonal coordinate system. Using this coordinate system, …

    iastate Repository record for Non-contact method to assess the surface roughness of metal castings by 3D laser scanning (opens in a new tab)

  3. Corona Ion Deposition: A Novel Non-Contact Method for Drug and Gene Delivery to Living Systems

    … This work presents the development of new methods for drug and gene delivery based upon similar principles as the traditional electrode driven membrane destabilization processes known as electroporation. This was achieved with non-contact corona ion deposition that temporarily increased the …

    usf Repository record for Corona Ion Deposition: A Novel Non-Contact Method for Drug and Gene Delivery to Living Systems (opens in a new tab)

  4. Using microwave Doppler radar in automated manufacturing applications

    … investigator's dissertation offers three methods that could help make "smart" CNC machine tools and industrial robots possible: (1) A method for detecting acoustic emission using a microwave Doppler radar detector, (2) A method for detecting tool wear on a CNC lathe using a Doppler radar …

    iastate Repository record for Using microwave Doppler radar in automated manufacturing applications (opens in a new tab)

  5. Microwave Instrumentation and Sensing Techniques for Quantum Efficiency and Minority-Carrier Lifetime Measurements

    A non-contact method characterizing the quantum efficiency of a solar cell using the microwave reflectance signature is presented in this thesis. Traditional solar cell quantum efficiency (QE) measurements are only possible near the completion of the fabrication process using contacts in direct …

    portland-state Repository record for Microwave Instrumentation and Sensing Techniques for Quantum Efficiency and Minority-Carrier Lifetime Measurements (opens in a new tab)

  6. Novel Synthetic Techniques for Fe(II) Triazole Spin Crossover Materials

    … quantities. These techniques are the direct-contact synthesis of solid reagents mixed under ambient conditions and thin-film synthesis via in situ airbrushing. Three compounds [Fe(atrz)3]SO4 (1), [Fe(Htrz)2(trz)](BF4) (2), and [Fe(atrz)3](BF4)2 (3) were synthesized using these novel …

    kent Download PDF for Novel Synthetic Techniques for Fe(II) Triazole Spin Crossover Materials (opens in a new tab)

  7. A novel microscopy technique for the characterization of carbon nanotubes

    … of this thesis is to develop a rapid, non-contact, method to distinguish carbon nanotubes (CNT) either as metallic or semiconducting since this distinction is important when CNT are used as high performance electron emitters. The widespread interest in carbon nanotubes has also led to a …

    ut-knoxville Repository record for A novel microscopy technique for the characterization of carbon nanotubes (opens in a new tab)

  8. A re-evaluation of the filter paper method of measuring soil suction

    The filter paper method is a soil suction measurement technique. Soil suction is one of the most important parameters describing the moisture condition of unsaturated soils. The measurement of soil suction is crucial for applying the theory' behind the unsaturated soils. The filter paper method is …

    ttu Repository record for A re-evaluation of the filter paper method of measuring soil suction (opens in a new tab)

  9. Campaigning in Context: A Practical Statewide Study of Correlations between Campaign Contact Methods, Partisanship, Timing, Frequency, Population Density, and Regionalism on Voter Turnout

    … mail interaction involving a non-partisan source contacting individuals in a localized urban area. I argue these investigations are unsatisfying. They do not consider hyperpartisanship, campaign micro-targeting strategy developed from large data collection, regional diversity, and repeated contact …

    ku Repository record for Campaigning in Context: A Practical Statewide Study of Correlations between Campaign Contact Methods, Partisanship, Timing, Frequency, Population Density, and Regionalism on Voter Turnout (opens in a new tab)

  10. Novel Methods for Weak Physiological Parameters Monitoring

    … this work, a bio-impedance analysis (BIA) based contact method and Wi-Fi band Doppler radar based non-contact method are proposed. The BIA system was able to estimate heart rate from the subject’s wrist with only four electrodes. The BIA results agree with the reference, which validates the …

    hawaii Repository record for Novel Methods for Weak Physiological Parameters Monitoring (opens in a new tab)

  11. An Analysis of the Relationship Between Television News Selection and Public Relations Techniques

    … techniques: elements of newsworthiness, personal contact, method of item dissemination, quantity of items submitted, and professionalism and credibility. Specific guidelines were developed for practitioners to follow in dealing with television news editors.

    unt Repository record for An Analysis of the Relationship Between Television News Selection and Public Relations Techniques (opens in a new tab)

  12. The effect of instant messaging on lecture retention

    … (“Is consistent use of the eye contact method necessary for success?”) versus not–related–to lecture (“Have you ever missed class because you couldn't find parking?”) instant messages in addition to note taking vs. no note taking. Student self–rating for multitasking ability, …

    texas Repository record for The effect of instant messaging on lecture retention (opens in a new tab)

  13. Inverse analysis of dental implant systems using finite element method

    … This model is further developed to a non-contact method for implant stability assessment. The presented models have been effectively to study different implant designs and monitor the osseointegration process, which provides useful information for clinical practice.

    nus Repository record for Inverse analysis of dental implant systems using finite element method (opens in a new tab) Download file for Inverse analysis of dental implant systems using finite element method (opens in a new tab)

  14. Characterization of Aerogel with Spectral Domain Optical Coherence Tomography & Preliminary Analysis of HELIX RICH Flight Data Investigation

    … Tomography (SD-OCT) is introduced here as a non-contact method to simultaneously determine both parameters. The technique meets the experimental requirements, achieving a thickness precision of ±2.1 μm and a group refractive index precision of ±0.0003. A procedure to derive the phase refractive …

    queens Repository record for Characterization of Aerogel with Spectral Domain Optical Coherence Tomography & Preliminary Analysis of HELIX RICH Flight Data Investigation (opens in a new tab)

  15. Investigation of Iron-Based and Topological Superconductors via Point-Contact Spectroscopy

    I report results of point-contact spectroscopy (PCS) measurements preformed on a variety of superconductors which are predicted to exhibit unconventional Cooper pairing mechanisms. Point-contact spectra of the iron pnictide BaFe_{1-x}$Pt$_x$As$_2$ are consistent with a two-gap isotropic s-wave …

    maryland Repository record for Investigation of Iron-Based and Topological Superconductors via Point-Contact Spectroscopy (opens in a new tab)

  16. Optical measurement of paper moisture content with application in paper pressing

    … in real-time. This thesis presents a novel non-contact method for measuring moisture content. The method is based on the high light absorptivity of liquid water in the 1400-1500 nm wavelength range. By using a short-wave infrared (SWIR) camera and an infrared LED to illuminate the paper, the …

    ubc Repository record for Optical measurement of paper moisture content with application in paper pressing (opens in a new tab) Download PDF for Optical measurement of paper moisture content with application in paper pressing (opens in a new tab)

  17. Development and characterisation of a novel optical surface defect detection system

    … of optical triangulation and provides a non-contact method of determining 3D pro file of a diffuse surface. Primary components of the developed system consist of a diode laser, CCfl5 CMOS camera, and two PC controlled servomotors. Control of the sample movement, image capturing, and …

    dcu Download PDF for Development and characterisation of a novel optical surface defect detection system (opens in a new tab)

  18. A Machine Learning-Based Non-Contact Respiratory Rate Monitoring Method Using an RGB Camera

    Non-contact measurement of Respiratory Rate (RR) is suitable for various clinical and home-based healthcare applications. RR monitoring can inform healthcare providers of early indicators of critical illnesses. However, the obtrusive nature of contact-based sensors for RR monitoring makes them …

    ottawa-retro Repository record for A Machine Learning-Based Non-Contact Respiratory Rate Monitoring Method Using an RGB Camera (opens in a new tab)

  19. Determining Effective Lifetime of Minority Carriers in Silicon Through Modulated Free Carrier Absorption

    … have been demonstrated to be an effective, non-contact, method to measure the minority carrier lifetime, particularly well-suited for use as an in-line measurement apparatus for the solar cell manufacturing processes In this thesis a non-contact, optical, pump-probe method has been used to …

    mcmaster Repository record for Determining Effective Lifetime of Minority Carriers in Silicon Through Modulated Free Carrier Absorption (opens in a new tab)

Page 1 of 5