Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 27 for “"Contact imaging"”

  1. Integrated CMOS optical sensors for fluorescence detection and contact imaging

    … optical sensors for fluorescence detection and contact imaging. Among many relevant techniques available for biological testing and molecular detection, fluorescence-based methods generally achieve the highest sensitivity and are the most widely used. We describe several contributions towards …

    maryland Repository record for Integrated CMOS optical sensors for fluorescence detection and contact imaging (opens in a new tab)

  2. Design and Evaluation of a CMOS Contact-Imaging System for Microfluidics

    A CMOS contact-imaging system for microfluidics is presented. The microsystem integrates a five-layer PDMS microfluidic network and a CMOS image sensor fabricated in a standard 0.18 µ­m technology. The CMOS image sensor consists of two 10×1-pixel array, an amplifier, and a control logic. The imager …

    byu Repository record for Design and Evaluation of a CMOS Contact-Imaging System for Microfluidics (opens in a new tab)

  3. An Integrated, Lensless, Miniature and Portable Contact Imaging System for Fluorescence Spectroscopy

    In this work, two different contact imaging systems were designed, fabricated and tested. The first system was designed to allow continuous, non-invasive imaging of calcium changes in multiple neurons. This is particularly important for studying brain functionality. First, emission filter for the …

    calgary Repository record for An Integrated, Lensless, Miniature and Portable Contact Imaging System for Fluorescence Spectroscopy (opens in a new tab)

  4. Compact Optical Sensing Systems for pH and Other Substances Detection - Theory and Implementation

    … research and industry. Optical sensors based on contact imaging realize the chemical detection in compact, efficient and inexpensive ways. In the first project real-time optical pH sensor based on complementary metal–oxide–semiconductor (CMOS) contact imaging and microfluidics, an optical contact …

    calgary Repository record for Compact Optical Sensing Systems for pH and Other Substances Detection - Theory and Implementation (opens in a new tab)

  5. Measuring Pulse Rate Variability During Motion Artifact with a Non-Contact, Multi-Imager Photoplethysmography System

    Non-contact imaging photoplethysmography is an exciting new field based on the principles of traditional photoplethysmography where viable signals can now be acquired without the use of contact equipment. Recent advances regarding non-contact imaging photoplethysmography have permitted a wide range …

    ohiolink Repository record for Measuring Pulse Rate Variability During Motion Artifact with a Non-Contact, Multi-Imager Photoplethysmography System (opens in a new tab)

  6. NEW MODALITIES FOR ANGLE CLOSURE DETECTION IN DIFFERENT CLINICAL SETTINGS OF A HIGH RISK POPULATION

    … requires a high level of expertise and contact with the patient's eye. This makes the technique unsuitable as screening tool for the non-specialist and has a poor uptake among ophthalmologists. In the last decade, non-contact imaging methods for angle closure assessment has been adopted. …

    nus Repository record for NEW MODALITIES FOR ANGLE CLOSURE DETECTION IN DIFFERENT CLINICAL SETTINGS OF A HIGH RISK POPULATION (opens in a new tab)

  7. Development of a Non-Contact Fluorescence Tomography System with Appropriate Reconstruction Techniques

    Molecular Imaging is a highly topical research field based on the combination of highly selective markers and appropriate imaging devices. It is mainly concerned with studying the effects of prototype drugs in small animals, following day by day the evolution of the disease in vivo. Amongst the …

    heid-diss Repository record for Development of a Non-Contact Fluorescence Tomography System with Appropriate Reconstruction Techniques (opens in a new tab)

  8. Self Assembling Porous Low-k Dielectric Thin Films

    … and atomic force microscopy (AFM) using both contact and non-contact imaging.

    texas-state Repository record for Self Assembling Porous Low-k Dielectric Thin Films (opens in a new tab)

  9. Towards precise, functional, and non-contact clinical intervention through ultrasound and photoacoustic approaches

    … urology, OB/Gyn, cardiology, and breast imaging, owing to its real-time imaging capabilities. Its ability to provide real-time tissue morphology has made it indispensable in surgical settings. Additionally, photoacoustic imaging has emerged as a promising modality, offering optical …

    jhu Repository record for Towards precise, functional, and non-contact clinical intervention through ultrasound and photoacoustic approaches (opens in a new tab)

  10. Evaluation of the GelSight Mobile™ 3-D imaging system for collection of postmortem fingerprints

    … GelSight Mobile™ is a handheld three-dimensional contact imaging system that can measure the topography of any surface regardless of the lighting conditions of the environment. The resolution of the images created is extremely high and can be used to measure single micron features. The goal of …

    bu Repository record for Evaluation of the GelSight Mobile™ 3-D imaging system for collection of postmortem fingerprints (opens in a new tab)

  11. Exploring conductive domain wall phenomena in ferroelectrics with nitrogen-vacancy magnetometry

    … Oersted field can be obtained, enabling non-contact imaging of current density with nanoscale resolution.<br/><br/>A full current-density reconstruction framework was implemented and validated using a metallic test structure, confirming the validity of the approach and establishing a minimum …

    qu-belfast Repository record for Exploring conductive domain wall phenomena in ferroelectrics with nitrogen-vacancy magnetometry (opens in a new tab)

  12. Defect Detection Via THz Imaging: Potentials & Limitations

    … up the field to new applications such as THz imaging. This non-destructive and non-contact imaging technique can penetrate through diverse materials such that internal structures, in some cases invisible to other imaging modalities, can be visualized. Today, there are variety of techniques …

    waterloo Repository record for Defect Detection Via THz Imaging: Potentials & Limitations (opens in a new tab)

  13. HRVCam: Measuring Heart Rate Variability With A Camera

    … Currently, HRV is accurately measured using contact devices such as a pulse oximeter. However, recent research in the eld of non-contact imaging Photoplethysmography (IPPG) has made it possible to extract vital sign measurements from the video recording of any exposed skin surface, such as a …

    rice Repository record for HRVCam: Measuring Heart Rate Variability With A Camera (opens in a new tab)

  14. Interfacial characterizations and analytical applications of chemically-modified surfaces

    … angstroms of the two surfaces that form the microcontact. The conversion of the ester functionality of DSU to a carboxylate functionality results in an increase in the friction at the tip-sample interface. The tip-assisted hydrolysis of DSU monolayer is reported in the third paper. It was found …

    iastate Repository record for Interfacial characterizations and analytical applications of chemically-modified surfaces (opens in a new tab)

  15. Reflective optics-based line-scanning spectral domain optical coherence tomography system

    … (OCT) is a high-resolution non-invasive and non-contact imaging technology. Traditionally, multi-axis spot-focused scanning is used for transverse scanning to obtain a two or three-dimensional OCT image. This increases the time to acquire an image and imaging performance is affected by motion …

    concordia

  16. Multispectral imaging for preclinical assessment of rheumatoid arthritis models

    … thesis is to determine whether multispectral imaging of murine arthritis models has the potential to assess the severity of arthritis symptoms in vivo in an objective manner. Given that pathology can influence the optical properties of a tissue, changes may be detectable in the spectral …

    birmingham Repository record for Multispectral imaging for preclinical assessment of rheumatoid arthritis models (opens in a new tab)

  17. Learning-Based Recovery of Physiological Signals from Video: Deep Unrolling, Temporal Modeling, and Uncertainty Quantification in Laboratory and Clinical Settings

    … have started examining non-invasive, non-contact, and remote ways of assessing physiological function; one such was is imaging Photoplethysmography (iPPG), the technique in which a non-contact RGB camera imaging the skin recovers a human's blood volume pulse (BVP) signal as if they are …

    jhu Repository record for Learning-Based Recovery of Physiological Signals from Video: Deep Unrolling, Temporal Modeling, and Uncertainty Quantification in Laboratory and Clinical Settings (opens in a new tab)

  18. CMOS Contact Imagers for Spectrally-multiplexed Fluorescence DNA Biosensing

    … Fourth, a spectrally-multiplexed fluorescence contact imaging microsystem for DNA analysis is presented. The microsystem has been quantitatively modeled and validated in the detection of marker gene sequences for spinal muscular atropy disease and the E. coli bacteria. Spectral multiplexing …

    toronto-retro Repository record for CMOS Contact Imagers for Spectrally-multiplexed Fluorescence DNA Biosensing (opens in a new tab)

  19. Development of Optical Coherence Tomography Systems for Intrasurgical and Pediatric Imaging

    <p>Optical coherence tomography (OCT) is a non-contact imaging modality that provides micron scale resolution of in-vivo tissue. Due to these characteristics, OCT is the clinical standard of care in ophthalmology for the diagnosis and monitoring of ocular diseases. Despite its success in adult …

    duke Repository record for Development of Optical Coherence Tomography Systems for Intrasurgical and Pediatric Imaging (opens in a new tab)

  20. Virtual Histology with Photoacoustic Remote Sensing

    … remote sensing (PARSTM) is an emerging non-contact imaging technique. PARS microscopy is an all-optical photoacoustic imaging modality that takes advantage of endogenous optical absorption present within tissues to provide contrast to enable non- contact label-free imaging. PARS has …

    waterloo Repository record for Virtual Histology with Photoacoustic Remote Sensing (opens in a new tab)

Page 1 of 2