Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"Contact monitoring"”.

  1. Exploring Web 2.0 as a Contact Monitoring Tool

    … of Web 2.0 applications for enhancing contract monitoring. Based on the literature, concepts of contract monitoring are described, and Web 2.0 applications are suggested to potentially enhance contract monitoring. Methodology: Since contract monitoring is not a standardized process, direct …

    texas-state Repository record for Exploring Web 2.0 as a Contact Monitoring Tool (opens in a new tab)

  2. Non-contact monitoring of respiration in the neonatal intensive care unit

    <p>Camera-based monitoring is an emerging sensing modality which has attracted widespread interest due to its potential to offer comfortable and concurrent measurements of the cardiorespiratory vital signs: the cardiac pulse rate, respiratory rate and peripheral capillary oxygen saturation.</p> …

    oxford Repository record for Non-contact monitoring of respiration in the neonatal intensive care unit (opens in a new tab)

  3. Non-contact monitoring of skin perfusion as a proxy for haemodynamic status

    … <br> <p>The use of video cameras in clinical monitoring has been explored in vital-sign estimation, and may offer both objectivity and higher sensitivity compared to the current subjective assessment of skin perfusion. However, its evolution as a monitor has been held back by practical …

    oxford Repository record for Non-contact monitoring of skin perfusion as a proxy for haemodynamic status (opens in a new tab)

  4. Implementation and evaluation of a two-dimensional laser doppler vibrometer system for non-contact monitoring of external stress loading of aluminum samples

    This thesis details the development and validation of a laser Doppler vibrometer-based measurement system that is capable of quantifying not only the normal vibration of a solid body but also the component of vibration that is parallel to the plane containing the surface of interest. LDV …

    gatech Repository record for Implementation and evaluation of a two-dimensional laser doppler vibrometer system for non-contact monitoring of external stress loading of aluminum samples (opens in a new tab)

  5. AI enable wireless sensing for remote speech recognition

    Contactless health monitoring is becoming an area of significant attention, especially after the impact of the COVID-19 pandemic. With the development of RF sensing technology, its application prospects in healthcare have garnered significant attention. Radio Frequency (RF) sensing techniques such …

    glasgow Repository record for AI enable wireless sensing for remote speech recognition (opens in a new tab) Download PDF for AI enable wireless sensing for remote speech recognition (opens in a new tab)

  6. Robust acquisition of Photoplethysmograms using a Camera

    Non-contact monitoring of vital signs, such as pulse rate, using a camera is gaining popularity because of its potential for ubiquitous in-situ low-cost health tracking. Camera-based vital sign monitoring measures small skin color changes due to blood flow, and can potentially be extracted from the …

    rice Repository record for Robust acquisition of Photoplethysmograms using a Camera (opens in a new tab)

  7. Understanding User-perception of Sleep to Inform Sensing and Provide Actionable Feedback

    … a wireless sleep sensing system that enables non-contact monitoring of sleep related physiological signals throughout the night. I also explore, through the design and implementation of a smart phone app, how a personalized sleep model can be used to provide meaningful and actionable feedback that …

    washington Repository record for Understanding User-perception of Sleep to Inform Sensing and Provide Actionable Feedback (opens in a new tab)

  8. Non-invasive vital-sign monitoring and data fusion in acute care

    … of machine learning and continuous vital-sign monitoring to improve detection of physiological deterioration.</p> <p>Two post-operative datasets are introduced; vital-sign data collected from 407 patients using manual and continuous methods, and vital-sign data collected from 447 patients using …

    oxford Repository record for Non-invasive vital-sign monitoring and data fusion in acute care (opens in a new tab)

  9. Contactless artificial intelligence-enabled radio frequency sensing for healthcare applications

    … if more direct care is needed. At present contact-based devices can provide real-time monitoring by deploying devices on a person’s body. However, placing devices on a person’s body all the time can be uncomfortable. Elderly people are also at risk of forgetting to wear devices. …

    glasgow Repository record for Contactless artificial intelligence-enabled radio frequency sensing for healthcare applications (opens in a new tab) Download PDF for Contactless artificial intelligence-enabled radio frequency sensing for healthcare applications (opens in a new tab)

  10. Acoustic Emission Beamforming for Detection and Localization of Damage

    … the development of numerous structural health monitoring and nondestructive evaluation techniques for quality assurance purposes and pre- and in-service damage detection. Exploitation of acoustic emission sensors coupled with a beamforming technique provides the potential for creating an …

    washington Repository record for Acoustic Emission Beamforming for Detection and Localization of Damage (opens in a new tab)

  11. The Charité Dome, a device to improve patients with dementia’s stay and non-contact measurement of vital signs and movement in emergency departments

    … stay in the ED. Since PWD rarely tolerate fixed monitoring devices, a novel developed non-contact monitoring system (NCMSys), measuring pulse/heart and respiratory rate as well as movement, might represent an appropriate alternative. Aim of this feasibility study was to test the reliability and …

    fu-berlin Repository record for The Charité Dome, a device to improve patients with dementia’s stay and non-contact measurement of vital signs and movement in emergency departments (opens in a new tab)

  12. Fit for Space: Leveraging a Novel Skin Contact Measurement Technique Toward a More Efficient Liquid Cooled Garment

    … A more direct garment contour and body contact monitoring procedure would benefit the functional clothing design community. Mobile measurement is especially important for functional garments, as the body-garment relationship changes over time during body movements. Here, we describe a …

    umn Repository record for Fit for Space: Leveraging a Novel Skin Contact Measurement Technique Toward a More Efficient Liquid Cooled Garment (opens in a new tab)

  13. Video camera monitoring to detect changes in haemodynamics

    … patient. In the last decade, the field of non-contact vital sign monitoring has emerged, with growing evidence that the remote photoplethysmogram (rPPG) signal can be used to estimate vital signs using video cameras. If the analysis of the rPPG signal can be expanded to include the estimation …

    oxford Repository record for Video camera monitoring to detect changes in haemodynamics (opens in a new tab)

  14. Thermography-Assisted Bearing Condition Monitoring

    … in condition based maintenance and condition monitoring methods, there is still a need for more reliable and accurate methods. The clear evidence of that need is the continued dependence on time based maintenance, especially for critical applications such as turbomachinery and airplane …

    ottawa-retro Repository record for Thermography-Assisted Bearing Condition Monitoring (opens in a new tab)

  15. A Non-Contact Vital Signs Monitoring Approach Using FMCW mmWave Radar

    … with respiration rate. Traditional contact-based methods are limited by their reliance on accessories attached to the body, making continuous monitoring challenging in both clinical and home environments. Moreover, wearable devices may not be suitable for patients with skin …

    auckland-tech Repository record for A Non-Contact Vital Signs Monitoring Approach Using FMCW mmWave Radar (opens in a new tab)

  16. Non-contact Assessment of Acute Mental Stress with Camera-based Photoplethysmography

    … camera-based photoplethysmography (cbPPG), a non-contact technique for the monitoring of cardiovascular vital signs, as an alternative for the assessment of acute mental stress that is suitable for everyday use. As a non-contact technique cbPPG is considered susceptible to artifacts. To overcome …

    qucosa-diss

  17. Design and Fabrication of Optomechanical Formalin Fixation Monitoring Systems Integrated with a Millifluidic Device

    … 2, 3, and 4) is to develop a tissue quality monitoring system for an automated millifluidic system for pathology and the development cycle includes design, fabrication, testing, and evaluation of the systems. In our lab, a novel automated millifluidic system for cancer diagnosis using core …

    washington Repository record for Design and Fabrication of Optomechanical Formalin Fixation Monitoring Systems Integrated with a Millifluidic Device (opens in a new tab)

  18. A Radar-Based In-Cabin Health Monitoring System

    The topic of in-cabin health care monitoring within vehicles has recently garnered significant attention. This technology serves two primary applications in a vehicle. First is the monitoring of the vital signs of drivers and passengers. Given the significant amount of time individuals spend …

    waterloo Repository record for A Radar-Based In-Cabin Health Monitoring System (opens in a new tab)