Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 26 for “"Contact potential difference"”.
-
Oil monitoring with an optically stimulated contact potential difference sensor
… utilized the concept of an optically stimulated Contact Potential Difference (osCPD) sensor to monitor oil properties. The osCPD technique is a variant of the contact potential difference (CPD) method used to obtain surface properties of materials. The technique uses modulated light to stimulate …
-
A Novel Sensor to Monitor Surface Charge Interactions: The Optically Stimulated Contact Potential Difference Probe
… charge transfer processes on a surface using a contact potential difference probe (CPD). The current investigation is an outgrowth of ongoing research on non-vibrating CPD probes (nvCPD) which led to the recent development of a novel measurement technique utilizing optical stimulation: optically …
-
Studies of the Properties of Designed Nanoparticles Using Atomic Force Microscopy
… Information relating to the work functions, contact potential difference, Young’s Moduli, elasticity, and viscoelasticity can be investigated using state-of-the-art atomic force microscope (AFM) experiments. Subsurface imaging of polystyrene encapsulated cobalt nanoparticles was achieved for …
-
Dynamic terrain following: nvCPD scanning technique improvement
… types of materials. One of these techniques is a contact potential difference (CPD) scanning technique. In this project a non-vibrating contact potential difference (nvCPD) method is utilized to measure a work function and a topographical structure of a sample surface. A sample is mounted on a …
-
Electron-Beam Retardation Contact Potential of Cuprous Oxide
The purpose of this research is to determine the contact potential of cuprous oxide, Cu2O, with respect to gold. A band model for cuprous oxide is presented. Single-crystal cuprous oxide is prepared from Oxygen Free High Conductivity copper equilibrated at 120°C and at atmospheric pressure. The …
-
Fringe Field Corrections in nvCPD Probe Tip Applications
… and analysis of the probe tip of a non-vibrating contact potential difference sensor. The non-vibrating contact potential difference (nvCPD) probe measures the work function variation on a conducting surface and recent experiments performed to measure the size of surface features have shown poor …
-
A triboelectric-based method for rapid characterization of powders
… experimental tribocharging data to estimate the contact potential difference of powders, which is a function of contact surfaces' work functions and depends on the physicochemical properties of materials. While the contact potential difference between the particles and wall is an essential …
-
Paviršinio potencialo tyrimai virpančio zondo sistema /
… a vibrating probe system, the measurements of contact potential for different materials (metals and polymers) are made, as well as measurements of ionization potential using an open Geiger-Müller system. From these measurements the work function of the capacitor system is calculated, which …
-
Electron Work Functions
… function in these studies was determined by a contact potential difference methods.
-
Investigation of surface damage resulting from static charging of moulded plastic components
Static Charging or Contact Electrification occurs on the separation from intimate contact of materials of dissimilar properties. The amount of charge transferred is dependent on, amongst other things, the contact potential difference between the materials. While a great deal of work has been …
-
Effect of Metallurgical Structure on Hydrogen Diffusion and Distribution in Steel
… steel consist of features which serve as potential traps for hydrogen. These trap sites include dislocations, grain boundaries, alloying elements, defects and interfaces. Thus, it is important to study the effect of metallurgical structure on hydrogen diffusion and distribution in steel. …
-
Rolling element skew measurement in a spherical roller bearing utilizing a CPD probe
This thesis incorporates an array of Contact Potential Difference (CPD) sensors to measure and monitor the degree of skew in the rolling elements of a spherical roller bearing. Skewing is the motion of a roller as it turns about an axis normal to the roller race interface. Roller skew is generated …
-
Interrogating Electronic and Ionic Carrier Motion in Halide Perovskites with Scanning Probe Microscopy
… We extracted the rate of change in the contact potential difference (CPD) at temperatures ranging from 283 – 313 K and generated Arrhenius plots to calculated activation energies. In the dark, we calculated activation energies ~0.61 eV, which agrees well with the activation energy …
-
Design of a Triboelectric Charge Measurement System
… to have fluctuations within the mass, and the contact of the Faraday cup with the exit tubing caused the powder delivery to have extra forces that skewed the mass measurements. • 2nd Design: A fluidized bed was utilized in tandem with vibrator, however external and internal factors like mass of …
-
Vibrating CPD Chemical Degradation Oil Sensor
Oil analysis is a broad field comprised of hundreds of individual tests that provide meaningful benefit by assessing one or more properties of lubricants or machines. Many tests are performed on new types of oil during research and development. The lubricants chemical, physical, or lubricating …
-
Characterization of InAs Quantum Dots in InP Nanowires Using a Kelvin Probe Force Microscopy
… the transfer process due to the substantial size difference between the probe and the nanowires. We applied a negative bias voltage of 4V to the probe for transferring these vertically grown nanowires. The process involves initially detaching the NWs from the growth substrate and then lifting them …
-
Real-time electrostatic charge monitoring of the wear surfaces and debris generated by sliding bearing steel contacts
… apply this technology to monitor oil-lubricated contacts. Precursor charge events have been successfully detected prior to the onset of significant wear and the charging mechanisms involved are thought to be tribocharging, triboemissions, surface charge variation and debris generation. This …
Page 1 of 2