Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 142 for “"Contact pressures"”

  1. Instrumentation and measurement of soil-tire contact pressures

    Thesis (M.S.)--Michigan State University of Agriculture and Applied Science. Dept. of Agricultural Engineering, 1958

    msu Repository record for Instrumentation and measurement of soil-tire contact pressures (opens in a new tab)

  2. Wear at high sliding speeds and high contact pressures

    … on metal wear at high sliding speeds and high contact pressures results in the melting of one or both of the sliding solid bodies due to heat generated at the contact interface. Understanding the influence of sliding speeds, contact pressures and material properties on wear rates is important …

    gatech Repository record for Wear at high sliding speeds and high contact pressures (opens in a new tab)

  3. The Effects of Shoe Type on Foot Functioning and Contact Pressures During Walking Performances

    … The prototype model decreased the encountered pressures and pressure integrals in the region of the second metatarsal-phalangeal joint. The use of the prototype shoe did not appear to unduly affect the gait of the subject.

    unt Repository record for The Effects of Shoe Type on Foot Functioning and Contact Pressures During Walking Performances (opens in a new tab)

  4. A Method to Calculate the Femoro-Polyethylene Contact Pressures in Total Knee Arthroplasty In-Vivo

    … computational method that generates the in-vivo contact pressures on the superior side of the polyethylene in total knee arthroplasty (TKA) based on in-vivo kinematic data. Ten clinically successful subjects (five fixed and five mobile bearing TKA), having Hospital for Special Surgery (HSS) knee …

    ut-knoxville Repository record for A Method to Calculate the Femoro-Polyethylene Contact Pressures in Total Knee Arthroplasty In-Vivo (opens in a new tab)

  5. The Effects of Surface Type on Experienced Foot Contact Pressures and Lower Limb Functioning During Running Performance

    … surfaces on lower limb motion and encountered pressures at two locations on the plantar surface of the right foot. Nine females performed five trials for each of four surface conditions. The results provided no evidence for surface-related changes in experienced foot contact pressures. Both …

    unt Repository record for The Effects of Surface Type on Experienced Foot Contact Pressures and Lower Limb Functioning During Running Performance (opens in a new tab)

  6. Investigation into the stress assisted damage of copper surface under single asperity: influence of contact pressures, surfaces stress states and environments

    … setup was used to investigate the effects of contact loads, surface stress state and surface environment on dissolution and damage of copper surface. A range of surface stress state was generated with a four-point-bending setup on a well-polished copper sample. Single asperity contact was …

    iastate Repository record for Investigation into the stress assisted damage of copper surface under single asperity: influence of contact pressures, surfaces stress states and environments (opens in a new tab)

  7. Development of a Computational Model to Predict the In Vivo Contact Mechanics of Modern Total Knee Arthroplasty

    … and extends it to the prediction of the in-vivo contact mechanics at the femoro-tibial articulation in modern knee implants for the deep knee bend activity. In this endeavor, this dissertation deals with the use of an inverse dynamic rigid body model characterizing the slip and roll behavior …

    utk-theses Repository record for Development of a Computational Model to Predict the In Vivo Contact Mechanics of Modern Total Knee Arthroplasty (opens in a new tab)

  8. Optimizing Radial Head Implant Geometry to Improve Contact Mechanics and Longevity

    … and function. Implant design has focused on the contact mechanics of the radial head articular dish; however, a comprehensive examination of radial head morphology is lacking. This thesis focused on the quantification of the radial head dish size, depth and curvature, and the landing and side …

    uwo Repository record for Optimizing Radial Head Implant Geometry to Improve Contact Mechanics and Longevity (opens in a new tab) Embargoed until 2026-12-20

  9. The Influence of Frontal and Axial Plane Deformities on Contact Mechanics during Squatting: A Finite Element Study

    … study the influence of knee deformities on knee contact mechanics and knee kinematics during squatting. A full-leg squat FE model was developed based on general open-source models and validated with in vivo studies to investigate the outputs under frontal malalignment (valgus 8° to varus 8°) and …

    uwo Repository record for The Influence of Frontal and Axial Plane Deformities on Contact Mechanics during Squatting: A Finite Element Study (opens in a new tab)

  10. Simulation of the passive and active motions of the replaced knee - effect of malalignment and ligament strains

    … In addition, the rig was used to conduct contact pressure measurements using Tekscan instrumentation. It was shown that implant design played a significant role in the passive stability of the replaced knee, and that each design was affected differently by altered ligament strains and …

    soton Repository record for Simulation of the passive and active motions of the replaced knee - effect of malalignment and ligament strains (opens in a new tab)

  11. On the biomechanics of the patellofemoral joint and patellar resurfacing in total knee arthroplasty

    … To quantify the patellofemoral joint kinematics, contact areas, and contact pressures, custom patellofemoral joint testing jigs, a continuous video digitizing system and a three dimensional magnetic tracking system and a custom software for the Fuji pressure sensitive film were developed. Six …

    goteborg Repository record for On the biomechanics of the patellofemoral joint and patellar resurfacing in total knee arthroplasty (opens in a new tab)

  12. Truck tire pavement contact pressure distribution characteristics for "super single" 18-22.5 and smooth 11R24.5 tires

    … sizes, allowable wheel loads and tire inflation pressures have increased. In order to establish pavements capable of sustaining the increased loading, the actual loading mechanisms and their magnitudes must first be identified. To identify the magnitudes, static testing was performed at The …

    texas Repository record for Truck tire pavement contact pressure distribution characteristics for "super single" 18-22.5 and smooth 11R24.5 tires (opens in a new tab) Restricted access

  13. Development and Validation of a Human Hip Joint Finite Element Model for Tissue Stress and Strain Predictions During Gait

    … as a first step in model development. Peak contact pressures of 8.0 to 10.6 MPa and contact areas of 576 to 1010 mm2 were predicted by this FEM during the stance phase of gait. This model was validated with in vitro measurements and found to be in good agreement with experimentally measured …

    calpoly Repository record for Development and Validation of a Human Hip Joint Finite Element Model for Tissue Stress and Strain Predictions During Gait (opens in a new tab)

  14. Feasibility Assessment of Compliant Polymers in TKR

    … gait cycle events, stair climbing and squatting. Contact pressure, contact area and von Mises stress of the PCU inlay were compared to literature and to a standard ultra-high molecular weight polyethylene (UHMWPE) inlay. The contact area of the articulating implant surfaces was on average 345% …

    queens Repository record for Feasibility Assessment of Compliant Polymers in TKR (opens in a new tab)

  15. Effects of Surgical Repair or Reconstruction on Radiocarpal Mechanics from Wrists with Scapholunate Ligament Injury

    … development of wrist osteoarthritis. Joint contact pressures are important mechanical factors in the etiology of osteoarthritis, and these can be determined non-invasively through computer modeling. Hence, the goal of this work was to investigate the effects of scapholunate ligament injury …

    ku Repository record for Effects of Surgical Repair or Reconstruction on Radiocarpal Mechanics from Wrists with Scapholunate Ligament Injury (opens in a new tab)

  16. Evaluation and Prediction of Elastohydrodynamic Lubrication Film Thickness Under Conditions of Severe Sliding and Zero Entrainment

    … and central film thickness of non-conformal contacts in fully flooded elastohydrodynamic lubrication (EHL) predict film collapse in the case of zero entrainment velocity (ZEV); however, past experiments show that films exist and support appreciable loads under this condition. To explore this …

    ohiolink Repository record for Evaluation and Prediction of Elastohydrodynamic Lubrication Film Thickness Under Conditions of Severe Sliding and Zero Entrainment (opens in a new tab)

  17. Modelamento biomecânico da atuação de aparelhos com parafuso expansor sobre estruturas mandibulares assimétricas através do método de elementos finitos

    … showed asymmetries in the distribution of contact pressures and indicated with precision the diagnosis of the patient's malocclusion. It was shown that theleft and right ends of the expansion screws move differently in relation to the mandible studied. The contact pressure between the …

    brazil-ufmg Repository record for Modelamento biomecânico da atuação de aparelhos com parafuso expansor sobre estruturas mandibulares assimétricas através do método de elementos finitos (opens in a new tab)

  18. Development of Surface Wear and Lapping Simulation Models for Hypoid Gears

    … in real-life hypoid gear sets impacting the contact patterns and the resultant noise behavior. In this study, a model is proposed to predict the surface wear of face-milled or face-hobbed hypoid gear pairs. This wear model incorporates Archard’s wear model along with loaded hypoid gear tooth …

    ohiolink Repository record for Development of Surface Wear and Lapping Simulation Models for Hypoid Gears (opens in a new tab)

  19. Engineering Kinesthetic Perceptions: The Restoration of Movement Sense in Upper Limb Prosthetic Use

    … our feedback system, and the RL-socket contact pressures were evaluated. Through comparison to the traditional socket data, it was determined that the novel socket not only successfully integrated a kinesthetic feedback system, but allowed investigators to target specific anatomical …

    alberta Repository record for Engineering Kinesthetic Perceptions: The Restoration of Movement Sense in Upper Limb Prosthetic Use (opens in a new tab)

Page 1 of 8